| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹7.5 L+₹6,985.50 (0.94%)Rejected-Finance ATRIA APARTMENTS 6TH FLOOR A 6 OPPOSITE GURUDWARA PERUMANOOR POST KOCHI 682015 | KOCHI | ERNAKULAM | KERALA | 682015 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.5 L+₹1.1 L (14.5%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.8 L+₹1.4 L (18.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹8.8 L+₹1.4 L (18.8%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | St George Engineering Works L1 | M/s T.P SHAJI L2 | ROTECH ENGINEERS AND BUILDERS L3 | Palakkal Agencies L4 | WELTRONENGINEERINGSERVICES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending day to day electrical complaints at Technical area of NPOL kochi for 08 Hrs (One shift) per day (from 08:30 Hrs to 17: 30 Hrs) for 5 days in a week except on Saturdays , sundays and Public holidays approved by AGE (I) R & D Kochi with skilled Man power ( Electrician) consisting of following and maintaining the Records like details of complaints , preperation Job card from complaint slip on standard format and completion reports of Job card from users/Department and including required tools and plants , minor electrical sparers like small piece of wire ,insulaton tape , screws etc required to rectifify the complaints and attending No-supply reports from Plant and Machinery installed in Various LABs and E/M Installations, etc including and replacing the spare parts in E/M fitting fixtures inside the Technical accommodation in scattered area at NPOL Complex at Kakkanad , spares required shall be measured and paid seperately in respective items complete as per the job card and all as specified and directed by the Engineer - In - Charge . | 225 | Per Shift | - | - | - | - | - |
| 2.00 | All as per the Item No 1.00 above but with skilled helper to electrician for 08 Hrs except on Saturdays ,Sundays and Public holidays approved by AGE (I) R & D Kochi to assist the skilled trades man (Sl Item No 01) for above work all as specified and as directed by Engineer-In -charge . | 225 | Per Shift | - | - | - | - | - |
| 2.01Note for Sl Item No I & II : (i) The person employed by the contractor has to check the Fittings/ Fixtures , Equipments and wiring as per the complaints/Job card, Spares for replacement shall be measured and paid as supply only under respective items in and no extra payment will be done for checking /Inspection of fittings . Contractor has to arrange the M & L for Printing the complaint registerand Job card as per standard format given by department and feedback reports to MES service centre to every day after completion of works directed by JE / Engineer-In charge irrespective of number of complaints . “ | ||||||||
| 2.02(ii) Contractor has to ensure minimum 01 electrician and 01 Helper to electrician for One Shift, if not, necessary Penalty / Recovery as per relevant PS clause shall be imposed. | ||||||||
| 2.03(iii) Contrator has to provide the tradesmen and helpers Tool Bags, - One for each trades men, with Minimum Tools like Line Tester, Test Lamps and other necessary tools for Sl Item No. 1 and 2 and electric Safety Shoes, all as specified and as directed by Engineer-in-Charge. (Note: The above Uniforms and T&P items shall be issued during the commencement of work. Contractor has to maintain necessary Issue / Receipt Register for the same and shall be submitted to the Department as directed by Engineer-in-charge). | ||||||||
| 3.00 | Supply only switch flush type 5 Amp single pole one way suitable for 230 Volt. Make: Anchor / Equivalent in Havell's | 100 | Each | - | - | - | - | - |
| 4.00 | Supply only switch socket combination flush type 5/6 Amp suitable for 230 Volt. Make: Anchor equivalent in Havell's | 50 | Each | - | - | - | - | - |
| 5.00 | Supply only switch socket combination flush type 15/16 Amp with shutter (four fixing holes suitable for 230 Volt. Make: Anchor / equivalent in Havell's | 50 | Each | - | - | - | - | - |
| 6.00 | Supply only switch modular type 5/6 Amp. Make: Legrand/Standard /L & T /Indo Asian | 15 | Each | - | - | - | - | - |
| 7.00 | Supply only switch modular type 15/16 Amp. Make: Legrand/Standard /L & T /Indo Asian | 20 | Each | - | - | - | - | - |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
27 May 2020, 6:00 pmClosed
AGE I RD KOCHI
AGE I RD, KAKKANAD KOCHI
REPAIRS/MAINTENANCE OF INTERNAL ELECTRIFICATION AND ATTENDING DAY TO DAY ELECTRICAL COMPLAINTS AT TECHNICAL AREA OF NPOL, KOCHI.
2020_MES_341800_1
8995 E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KAKKANAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I RD KOCHI
₹18,000
Yes
29 Aug 2025
30 Apr 2020
30 May 2020
30 Apr 2020
27 May 2020
14 May 2020
30 Apr 2020 - 12 May 2020
Amount
Attending day to day electrical complaints at Technical area of NPOL kochi for 08 Hrs (One shift) per day (from 08:30 Hrs to 17: 30 Hrs) for 5 days in a week except on Saturdays , sundays and Public holidays approved by AGE (I) R & D Kochi with skilled Man power ( Electrician) consisting of following and maintaining the Records like details of complaints , preperation Job card from complaint slip on standard format and completion reports of Job card from users/Department and including required tools and plants , minor electrical sparers like small piece of wire ,insulaton tape , screws etc required to rectifify the complaints and attending No-supply reports from Plant and Machinery installed in Various LABs and E/M Installations, etc including and replacing the spare parts in E/M fitting fixtures inside the Technical accommodation in scattered area at NPOL Complex at Kakkanad , spares required shall be measured and paid seperately in respective items complete as per the job card and all as specified and directed by the Engineer - In - Charge .
All as per the Item No 1.00 above but with skilled helper to electrician for 08 Hrs except on Saturdays ,Sundays and Public holidays approved by AGE (I) R & D Kochi to assist the skilled trades man (Sl Item No 01) for above work all as specified and as directed by Engineer-In -charge .
Note for Sl Item No I & II : (i) The person employed by the contractor has to check the Fittings/ Fixtures , Equipments and wiring as per the complaints/Job card, Spares for replacement shall be measured and paid as supply only under respective items in and no extra payment will be done for checking /Inspection of fittings . Contractor has to arrange the M & L for Printing the complaint registerand Job card as per standard format given by department and feedback reports to MES service centre to every day after completion of works directed by JE / Engineer-In charge irrespective of number of complaints . “
(ii) Contractor has to ensure minimum 01 electrician and 01 Helper to electrician for One Shift, if not, necessary Penalty / Recovery as per relevant PS clause shall be imposed.
(iii) Contrator has to provide the tradesmen and helpers Tool Bags, - One for each trades men, with Minimum Tools like Line Tester, Test Lamps and other necessary tools for Sl Item No. 1 and 2 and electric Safety Shoes, all as specified and as directed by Engineer-in-Charge. (Note: The above Uniforms and T&P items shall be issued during the commencement of work. Contractor has to maintain necessary Issue / Receipt Register for the same and shall be submitted to the Department as directed by Engineer-in-charge).
Supply only switch flush type 5 Amp single pole one way suitable for 230 Volt. Make: Anchor / Equivalent in Havell's
Supply only switch socket combination flush type 5/6 Amp suitable for 230 Volt. Make: Anchor equivalent in Havell's
Supply only switch socket combination flush type 15/16 Amp with shutter (four fixing holes suitable for 230 Volt. Make: Anchor / equivalent in Havell's
Supply only switch modular type 5/6 Amp. Make: Legrand/Standard /L & T /Indo Asian
Supply only switch modular type 15/16 Amp. Make: Legrand/Standard /L & T /Indo Asian
Supply only socket 5 Amp modular type 5/6 Amp. Make: Legrand/Standard /L & T /Indo Asian
Supply only socket modular type 15/16 Amp.Make: Legrand/Standard /L & T /Indo Asian
Supply only bell switch modular type 5/6 Amp. Make: Legrand/Standard /L & T /Indo Asian
Supply only ballast copper wound vacuum pressure impregnated suitable for 36/40 Watt FTL fitting Make: Crompton /Philips/Bajaj
Supply only ballast copper wound vacuum pressure impregnated suitable for 18/20 Watt FTL fitting Make: Crompton/ Philips/Bajaj
Supply only electronic ballast suitable for 36/40 Watt FTL fitting Make: Crompton /Philips/Bajaj
Supply only electronic ballast suitable for 18/20 Watt FTL fitting Make: Crompton /Philips/Bajaj
Supply only electronic ballast suitable for 1 X 28 FTL /36 Watt CFL fitting Make: Crompton /Philips/Bajaj
Supply only electronic ballast suitable for 2 X 28/36 Watt FTL/CFL fitting Make: Crompton / Philips/Bajaj
Supply only starter for FTL fitting 20/40 watt . Make: Crompton /Philips/Bajaj
Supply only tube rod 36/40 Watt Make: Philips/Crompton /Bajaj/Wipro
Supply only tube rod 14/ 18/20 Watt Make: Philips/Crompton /Bajaj/Wipro
Supply only tube rod 28 Watt Make: Philips/Crompton /Bajaj/Wipro
Supply only PL-Lamp 18/ 36 W Pin Type Make: Crompton /Philips/Bajaj
Supply only PL- Lamp 11/13/15 W Pin Type Make: Crompton /Philips/Bajaj
Supply only CFL 85 watt Make: Crompton /Philips/Wipro/Havell's.
Supply only bipin holder for FTL fitting 36/40 Watt Watts any height,all as specified and directed by Engineer-in-Charge.
Supply only incandcent lamp of 60/100 Watt ,all as specified and directed by Engineer-in-Charge. Make: Philips/ Havells/Bajaj /Wipro
Supply only comptalux lamp of 100 watt suitable to fix in metal /PVC holder in ceiling /Wall mounted fitting ,all as specified and directed by Engineer-in-Charge. Make: Philips : Spotone/Equivalent in Havells/Bajaj /Wipro
Supply only 3 pin plug top 6 Amp Make: Crabtree/ Havell's /Anchor
Supply only 3 pin plug top 16 Amp Make: Crabtree/ Havell's / Anchor
Supply only bell AC 230 Volt Ding Dong type.240 Volt AC supply ,Make Anchor/Leader/Havell's .
Supply only Bell push, flush type, 5 amp,all as specified and directed by Engineer-in-Charge.Anchor/ Havell's
Supply only angle Batten holder/ insulator body of PVC/Poly Carbonate type /Batten brass holder suitable for for 230 volts , 6 Amp 50 Hz ,all as specified and directed by Engineer-in-Charge. Make: Anchor/Havell's
Supply only switch piano flush button single pole two way 5 AMP ,all as specified and directed by Engineer-in-Charge. Make: Anchor/Havell's
Supply only fan condenser / capacitor suitable for ceiling fan of 1200 mm sweep/Exhaust fan of 225/300/450 mm sweep complete all as specified and as directed by the Engineer - in - Charge.Make:Usha/Siemens/Keltron Note: Fixing charges for capacitor deemed to be included in SL Item No 01 & 02 above .
Supply only modular type fan regulator socket type AC 230V electronic type complete ,all as specified and directed by Engineer-in-Charge. .Make : Indo Asian / MDS Legrand / Havell's/ L & T /Standard.
Supply only electronic fan regulator socket type ,step type AC 230V ,single pole electronic type Make: Anchor \ Havell's
Supply only in ceiling rose surfaces bakelite three terminals ,all as specified and directed by Engineer-in-Charge. Make: Anchor/Leader
Supply only LED rod 18 Watt Double Side Connection Ultra bright glass LED Tubelight with very high efficacy suited for installation in existing T8 tubelight with G13 lamp holders to give glare free light complete fix to existing FTL frame after taking out unserviceble choke, rod and starter complete al las directed by Engineer in charge.
Disconnecting and taking down from any height, existing tube light fittings 1 x 36/40 or 2 x 36/40 & 1 x 20 watt of any type/ make to store for credit all as directed by EIC.
S & F in replacement LED fitting 15/18 Watt ceiling mounted /Surface mounted downlight with white powder coated polycarbonate housing and pressure die-cast heat complete all as specified and as directed by Engineer-in -Charge . Make: Havell's Cat Part No. LHEAAGP7PL1W015 /Equivalaent in Luker Cat Part No. LPS RR 18 /Crompton
S & F in replacement LED fitting 20 Watt Ceiling / Surface / wall mounted orr fic to haanging GI pipes from ceiling including LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with rod complete all as specified and as directed by Engineer-in -Charge . Make: Havell's Cat Part No. LHEWEBP7IN1W020 /Equivalaent in Luker /Crompton .
S & F in replacement LED fitting 10 Watt Ceiling / Surface / wall mounted orr fic to haanging GI pipes from ceiling including LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with rod complete all as specified and as directed by Engineer-in -Charge . Make: Havell's Cat Part No. LHEWEBP5IN1W010 /Equivalaent in Luker /Crompton .
Suplly and fix in repacemnt MCB DB double door with necessary lugs for incomming and outgong connections up to Copper/Aluminium conductor og 16 sq mm fixed on wall surface/concealed after taking down the existing DB of any make/ rating from any height for the following Way
MCB DB SPN 8 Way Make : Legrand / Equivalent in L & T /Indo Asian /Standard
MCB DB SPN 12 Way Make : Legrand / Equivalent in L & T /Indo Asian /Standard
MCB DB TPN 6 way Make : Legrand / Equivalent in L & T /Indo Asian /Standard
Supply and fix in replacement MCB of following rating . Make: Legrand/L &T/ Standard Havell's/ HPL
MCB SP 6 to 40 Amp
MCB DP 6 to 32 Amp
MCB TP 6 to 40 Amp
MCB TPN 40 to 63 Amp
MCB TPN 100 Amp
Supply and fix replacement 240V 32 Amp double pole and earth enclosure with a two pin and earth plug and socket concealed on wall complete with one MCB DP 32 Amp SP including taking down old unserviceble MCB Enclosure of any type /make complete all as specified and as directed by engineer-n -charge. Make : Legrand /L & T /Indo Asian /Standard
Supply and fix replacement triple pole + Neutral and earth enclosure with a three pin - neutral and earth plug including one MCB 4 pole 32 Amp, 10 KA , concealed on wall including taking down old unserviceble MCB Enclosure of any type /make complete all as specified and as directed by engineer-n -charge Make : Legrand /L & T /Indo Asian /Standard.
S & F in replacement of PVC rectangular block of sizes of following size for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing metal/PVC/Wodden boxes with back and top all as directed by EIC.
100 mm X100 mm square,50 mm deep
175 mmX100 mm , 50 mm deep
200mmX150 mm , 50 mm deep
250mmX200 mm 50 mm deep
M&L industrial laminated sheet board/hylem sheet of size 6 mm thick of any size for for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing laminated top cover all as directed
Taking down carefully ceiling fans / exhaust fans from any height and of any make and sweep including disconnecting the cable from ceiling rose and Deposited to MES store for repair/Replacement and refixing the same as specified and as directed by the Engineer - in - Charge.
M & L Dismantling and taking down unserviceble Ceiling fan/Exhaust fan fixed on ceiling/Wall of builing ( Work shop /Tank Building /Auditorium /Conference hall ) of sweep 1200 for ceiling fan and 300/450/600 for exhaust fan mounted on Wall or suspended from ceiling of ceiling height max up to 11 Mtr from ground level ,by placing adjustable step type ladder inside the building and deposited to store and refix the same after repair all as directed Note for Sl Item no 48 & 49 : Repair work shall be done by department only dismatling and refixing job is involved in this scope.
M & L Dismantling and taking down unserviceble ceiling mounted light fitting at Seminar hall /Auditorium at NPOL Complx having the ceiling height max up to 11 Mtr from ground level ,by placing adjustable step type ladder inside the building for replacemewnt of worn out accessories or carrying to store and refix the same after repair all as specified and asdirected.Note: Spares for repair shall be measured and paid seperately.
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) compete (fittings such as switches, ceiling roses, pendants, regulators,sockets etc for re use at site (to be measured separately ) removing material to store.
M&L for point wiring complete as specified with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathed FR cable, copper conductor multistranded passing through including existing PVC concealed conduit on wall /Ceiling or drawn through new PVC casing caping in wall/Floor as per site with concealed modular metal box/Surface PVC modular box suitable for logic modular switches , sockets , fan regulators etc and logic modular white plates of suitable size as required at site with PVC insulated FR unsheathed stranded copper conductor of size 1.5 sq mm as earth wire connected to common earth dully as specified for one light point / fan point controlled by one switch .
Note: - (i) Rate quoted shall include for cost of making concealed metal modular box on wall including cutting and sinking of boxes and making good the walls (No extra payment will be made for the same) (ii) Provision of blank plates as per site requirement (No extra payment will be made for the same)
All as per item No 52 above but for 5 Amp switch socket on the same board
All as per item No 52 above but for 5 Amp switch socket on independent board
All as per item No 52 above but size of cable 2.5 sq mm for 15 Amps switch socket with earth wire of 2.5 sq mm
Taking down the old sub main wiring and M/L for new sub main wiring of follwing sizes by laying PVC unsheathed copper multistranded conductor , FRLS drawing into and including PVC heavy duty PVC casing caping/ through PVC conduit /Existing Conceled metal /PVC pipes with copper earth conductor single core PVC unsheathed multistranded one run complete all as specified and as directed by engineer-in -charge .
2 X 4 Sq mm +1 X 4.0sq mm for earth wire
2 X 6 Sq mm +1 X 6.0 sq mm for earth wire
M/s T.P SHAJI
ROTECH ENGINEERS AND BUILDERS
Palakkal Agencies
WELTRONENGINEERINGSERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .