Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | Admitted-Finance |
| 2 | Admitted-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
| 3 | Rejected-Technical 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | Rejected-Technical Not Recommended as the firm has not uploaded list of work in hand |
| 4 | Rejected-Technical HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | Rejected-Technical Not Recommended as the firm has not uploaded list of work in hand |
Tender Value
₹39.5 L
EMD Value
₹79,040
Closing Date
29 Oct 2021, 6:00 pmClosed
SHRI T C SHISHODIYA, DCWE (C)
MULTAN LINE ARMY AREA JODHPUR
Provn Of Power Supply With Stand By Gen Set For Oxygen Generation Plant And Provn Of Oxygen Gas Pipe Line With Duct Upto Existing Manifold At MH Jodhpur Under GE Shikargarh
2021_MES_475883_1
CWE (A) JODH/SKG-32 OF 2021-22
Open Tender
Civil Works
Item Rate
150 days
GE Shikargarh
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE Shikargarh
₹79,040
11 Nov 2021
17 Sept 2021
30 Oct 2021
17 Sept 2021
29 Oct 2021
8 Oct 2021
Amount
Supply, installation, commissioning and testing of transformer step down Copper Wound, outdoor type 11 KV on HT side and 433 Volts, 3 ph & 4 wire on LT side complete with standard fittings / accessories gauges and first fill of oil, of capacity 125 KVA with tapping on HT side to vary the secondary voltage by ±7.5% in step of ±2.5% complete with electrical connections on HT & LT side including all the accessories/fittings as mentioned in SSR Part - I Para 19.14.1.1 to 19.14.2.2 and confirming to IS-2026 or latest, duly installed on PCC platform including RCC Foundation for Transformer and Cattle fencing (1.5m high) around complete all as directed.
Supply and erection in vertical position steel tubular swaged pole type 410 SP- 55 (11 mtr long ) with Mild Steel base plate of size 30cmx30cmx6 mm thick continuously welded to pole , finial taper plug ,bolts ,nuts and screws all as specified including factory painted with two coats of black bituminious paint internally throughout and externally for embedded position and two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip (total 4 Nos ) with black and yellow paint including numbering complete all as specified .
M&L stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate No. 1 of SSR – 2009 Part –I complete all as specified and directed by Engr-in-Charge. Note : (Loop type insulator excavation , stay clamp, nuts, bolts, washers and concrete to be measured and paid separately.
S&F of Aluminium conductor, steel reinforced (ACSR) of any size, for joints & jumpering to connect HT Pole to GOD, complete all as specified .
S&F Pin Insulator, porcelain, vitreous white, brown or green insulator incl one galvanized mild steel spindle,two galvanised iron washers and one galvanised iron nut , 150 mm height , 150 mm dia for 11000 volts grade.
S&F Disc type Porcelain Insulator, vitreous brown , large size with overall dimension 90x140mm clearence of hole 25.5 mm ,working pressure 11000 volts all as specified and directed by Engr-in-charge.
S&F cross arms, bracing, supports clamps & back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed.
Material and labour for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation/ coping of poles including use of necessary form works for rough finished surface complete all as spd.
Material and labour for PCC 1:3:6 type C–2 (using 40 mm crushed graded stone aggregate/as in foundation for stay and necessary form work for rough finished surface complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1, using stone aggregate 20mm graded, with and incl necessary form work where required and fair finish to the exposed surfaces, complete all as specified & directed.
S&F of Air break gang operated switches of any type (horizontal or vertical type), triple pole, mechanically operated, mounted on HT insulators and galvanised steel frame with operating rod of 25 mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 400 Amps suitable for 11000 volt , 50 Hz with and incl 9 nos insulator and drop out fuse carrier element, complete all as specified and directed.
Material & Labour for danger notice plate of 1.6 mm thick and size not be less than 25x20 cm, made of mild steel sheet, vitreous white enamelled, with letters i.e. "DANGER 11000 VOLTS" (in English As well as in HINDI ) and conventional skull and bones signal in red colour and fixed with MS clamps, nuts, bolts and washers of suitable size, complete all as directed.
S&L tubes galvanised in repair with all fittings and fixed complete to walls and ceilings or laid in floors/with pole/trenches "Light grade" 80 mm dia for the protection of the U/G cable complete all as specified and as directed by Engineer-in-Charge.
Supply jointing and testing outdoor type cable end termination joint (Heat shrinkable) suitable for aluminium conductor cable of size 95 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.
S&F of HT lightening arrester metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements transmission class discharge capacity 65 kilo amps suitable for 11000 volts including brackets, clamps, nuts, bolts ,washers and connected with GI earth wire of 4mm dia, with and incl dismantling/taking down of existing unserviceable LA, complete all as specified and directed.
Supply, laying, testing and commissioning of semi conducting compound conductor screened PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm x 3 core confirming to IS 7098 Part-II, suitable for earthed system complete all as directed.
Supply, laying, testing and commissioning of semi conducting compound conductor screened PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm x 3.5 core confirming to IS 7098 Part-II, suitable for earthed system complete all as directed.
Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 m depth for foundation of poles and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material/soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover class HVP, Type 1 with peak, size 300mm x 180mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for HT UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for LT UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 meter below normal ground level connected to galvanized earth strip of size 25x4mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, commissioning and testing of silent type diesel engine driven generating set with canopy as per guideline issued by (Ministry of Environment & forest notification dated 12 July 2004, Central pollution control board letter No B-31613/7/93/PCI-II dated 19th Jan 2005 & Noise pollution control rules 2000 dated 14 Feb 2000), 415 volts, 0.8 power factor, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 160 KVA / 128 KW at NTP capable of operating between temperature range at Jodhpur, Rajasthan (Automatic on main failure & alternator of suitable capacity and RPM coupled with each other & capable of taking 10% over load for one hour on every 12½ hours with flexible coupling mounted on common base pate on Antivibration pads on foundation as recommended by manufacturer. The DG set shall comprise of Electric starter motor with battery, Turbo starter comprising all standard fittings, fixtures & all piping etc as listed at Srl page No 136(I).
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 meter below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all as directed.
Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe as per BS 2871, Lloyd certified complete all as directed of size 35mm OD x 0.9mm thick.
Supply and fixing of Isolation Valves complete all as directed for 35mm ball valve.
Supply and laying of PVC Pipe 50mm with complete fitting.
Supply and laying of Pressure Gauge 10 Kg complete all as directed
S&F Soft/ loose soil Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out
M&L 1:4:8 Type D-2 (40 mm graded) Cement concrete in surface channels and drains
M&L RCC Design mix M20 (20 mm graded aggregate) for Walls, retaining walls, basement walls, ballast walls and the like; ny thickness; above top of footings; including attached pilasters and buttresses
M&L RCC Design mix M20 (20 mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L FE-410 Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per Srl Item No 38 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L Flat Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter
Preparing new plastered/ pointed surfaces and material & labour for applying two coats of cement base paint on walls including one base coat of white wash etc., complete all as specified and as directed.
Anil Builders
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .