Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹7.1 L+₹18,080 (2.62%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹7.2 L+₹35,595 (5.17%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹7.5 L+₹56,967 (8.27%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹8.5 L+₹1.6 L (23.9%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹19,880
Closing Date
16 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
REPAIR/MAINT OF PERIMETER AREA SECURITY LIGHTS, WATCH TOWER LIGHTS AND CONNECTED ITEMS AT AF STN PHALODI
2020_MES_377891_1
8294/A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category b(i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority. - Refer Note
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹19,880
Yes
13 Nov 2020
15 Sept 2020
19 Oct 2020
15 Sept 2020
16 Oct 2020
3 Oct 2020
15 Sept 2020 - 26 Sept 2020
60 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for pole foundation, etc. or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for pole foundation, etc. or for laying underground cable, pipe lines etc. in hard/dense soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose or hard dense soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line, making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type B1 complete all as specified and directed.
Laying only, connecting, testing, commisioning and jointing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables of size cross sectional area of cable 35 Sqmm, 3.5 core with stranded aluminum conductors,1100 volts grade, laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors/equipment etc including cable lugs and jointing materials and including disconnecting & taking out old unserviceable LT UG cables of any size/type complete all as specified and directed for following cross sectional areas of cables :- Note :- LT UG XLPE cables will be issued under Sch 'B' free for laying/fixing only. (ii) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ.
M & L for dry tibba sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover to cable all as per standard schedule rates Part-I (2009) complete all as specified and directed. Note:- Thickness after punning shall be considered for payment.
Supplying and laying in renewal for un-reinforced precast cement concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided as coping to poles, flood lights, tarmac light, foundation etc complete all as specified and directed.
M & L for cement concrete PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in pole foundation and like complete all as specified and directed.
M & L for cement concrete PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in pole coping and like complete all as specified and directed.
Supplying, transporting to site erecting and fixing in true vertical position of steel tubular swaged pole, 9 metres long, type 410, SP-31, with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including painting with two coats of aluminium paint over and including one coat of aluminium oxide primer and two coats of bituminous paint inside and outside of bottom portion embedded in concrete upto 1.80 m height of pole and including fixing of 6"" width reflection paint in alternate coloured on pole and marking pole nos with black synthetic enamelled paint and including dismantling of existing unserviceable PCC pole of any size/type complete all as specified and directed. Note:- Excavation and earth work, PCC etc shall be measured and paid for separately under respective items of BOQ.
M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth by scrubbing the existing painted surfaces and applying two coats of synthetic enamel paint over and including a coat of red oxide primer for LT panel board/feeder pillar box of any size and shape complete all as specified and directed.
Note for Srl Item Nos. 14 to 49 :- (i) Contractor will depute One Electrician and One helper per day for daily basis for attend the complaints all as directed by Engineer-in-charge. The quoted rate of items shall be deemed to be inclusive of this aspect. (ii) Contractor/Supervisor will collect electrical complaints from concern JE on daily basis and will complete on same day and submit the performance silip duly signed by user's/complaintant. (iii) Contractor will provide suitable transportation for attending daily basis complaints on site like cycle/Motorcycle etc to each electrician/helper with proper driving licence/Halmet etc and keep permission of vehicle for inside premises by competent authority. (iv) Contractor will provide equipments like Hydra, excavation tools, discharge rod, Tester, Test lamp, Multi meter, cutting/side plier, screw driver, plier, electric hammer, drill machine, electrical wall cutting machine, wiring steel wire, industrial safety helmet, hand gloves, safety materials and related essential tools etc on his own arrangement for rectifying the complaint and also screws, nut, bolt, insulation tape, as per site requirement and no other payment will be made for the same.
M & L for PVC insulated and sheathed weather proof flat two core cable of size 10 sqmm multistrand aluminium conductor for connection and including taking down old unserviceable cable complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 200 Amp, ultimate breaking capacity 36 KA, Ics = 100% lcu (Icu = 36 kA), 50 Hz, confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal (70-100% of ln) and adjustable magnetic (5-10 of ln) release, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 160 Amp, ultimate breaking capacity 16 KA, Ics = 100% lcu (Icu = 16 kA), 50 Hz, confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal (70-100% of ln) and fixed magnetic (10 x ln) release, complete all as specified and directed.
S & F in renewal for MCCB, four pole, 415 Volts, 100 Amp, ultimate breaking capacity 16 KA, Ics = 100% lcu (Icu = 16 kA), 50 Hz, confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal (70-100% of ln) and fixed magnetic (10 x ln) release, complete all as specified and directed.
S & F in renewal for MCB, four pole, 63 Amps, 415 volts, AC, C-curve, rupturing capacity 10KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed.
S & F in renewal for surge protector 5 KV suitable for upto 75 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
S & F in renewal for surge protector 5 KV suitable for 75 W to 150 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
S & F in renewal of electronic driver suitable for 45/48 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
S & F in renewal of electronic driver suitable for 60 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
S & F in renewal of electronic driver suitable for 72 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
S & F in renewal of electronic driver suitable for 120 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
S & F in renewal of electronic driver suitable for 200 Watts LED light fitting complete all as specified and directed. Make: Phillips / Bajaj / Crompton / Havells.
Dismantling and disconnecting electrical connection and taking out carefully old serviceable/ unserviceable pole mounting brackets and GI bend for street light fittings with MS clamps, nut, bolts, street light fittings etc from PCC/Steel poles complete all as specified and directed. Note :- (i) Mounting brackets, GI bend with MS clamps, nut, bolts, street light fittings etc, which are taking down/removed shall be deposited at AGE E/M (AF) Phalodi store yard. (ii) Cost of Necessary tools and plants such as ladders, hydra for removal of mounting brackets, light fittings, nuts, bolts etc shall be deemed to be included in the unit rate quoted.
S & F in renewal of double swan neck made out of steel tube, medium grade, 32 mm dia bracket 2.0 mtr long by hydraulic pressed mechine bend to require arc shape and consists/welded in 125 mm dia of GI tube 30 cm long cap (for mounting on pole) and suitable size fixed with bolts, nuts and washers including drilling holes and grouting with the same for fixing bolts as required & incl duly painted with two coat of aluminum paint over a coat of aluminum red oxide primer and fixing with lights fittings on the existing old street light poles complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for renewal of mounting brackets, light fittings, nuts, bolts etc shall be deemed to be included in the unit rate quoted.
S & F in renewal of Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Astronomical time switch, high voltage and low voltage protection, 3 pole/230V for 12 KW load equally distributed over 3 phases, minimum IP-54 degree of protection complete all as specified and directed. Make - IndoAsian, Model - TimeLite (TIMELITE DISTRIBUTION BOARDS), HSN Code-8537, Cat Part No - TL065AS0 or Equivalent Make of CG/Philips/Havells.
S & F in renewal of energy effcient LED street light fitting of 60 Watt seasonal RTC control with dimmable type, epoxy poweder coated pressure die cast alumminium housing to act as heat sink for effcient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for beter throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fittinng should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting & including making electrical connection and including bracket of suitable size/ as per existing upto 1.5mtr long & MS flat clamp of suitable size/as per existing complete all as specified and directed.
S & F in renewal of flood light luminaire of HPSV/MH, with 200 Watt LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish, high power LED with IP- 66 protection, fins are provided on housing for better thermal management, heat resistant tempered glass for protection with 5 kv surge protection, 5700ANSI (CCT)K complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires, security light /high mast light fittings etc should be deemed to be included in the unit rate quoted. Make :- Halonix HLFLD-ML15-200-CWL or CG, Model-Secure, Cat Part No. LSFO-200-CDL/60 or Bajaj, Production Code- 169783, Type- BARFEG200WLED or Wipro - LF20-272-060-57-XX or eqvt Make & Model of Philips/ Havells.
S & F in renewal of flood light luminaire of HPSV/MH, with 250 Watt LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish, high power LED with IP- 66 protection, fins are provided on housing for better thermal management, heat resistant tempered glass for protection with 5 kv surge protection, 5700ANSI (CCT)K complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires, security light /high mast light fittings etc should be deemed to be included in the unit rate quoted. Make :- Halonix HLFLD-ML10-250-CWL or CG, Model-MAGPIE, Cat Part No. LFLPI-250-CDL/60 or Bajaj, Production Code- 169819, Type- BARFEG240WLED or Wipro - LF20-342-060-57-XX or eqvt Make of Philips/ Havells.
S & F in renewal for circuit/sub main wiring for junction box to street light fitting with 1.5 Sqmm, 3 core, PVC insulated and PVC round sheathed multistranded copper conductor flexible FRLSH industrial cable 1100 V grade as per IS 694:1990 & including fixing arrangement and disconnection of street light fittings and re-fixing the same complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc shall be deemed to be included in the unit rate quoted.
S & F in renewal of FRP junction box of external size 295mm X 255mm X 120 mm and internal size 250mm X 200mm X 105 mm having 4 Nos aluminium bus bar of size 20mmX4 mm fixed on epoxy insulators with and including C-curve type MCB SP 6 Amps, rupturing capacity 10KA, fixed on the pole with clamps, nut bolts etc. complete all as specified and directed. Make :- Sintex, Model No- GS-JB-2520 or Equivalent Make of Prayag/ Reliance.
S & F in renewal for rigid non-metallic PVC conduit of 20 mm dia, heavy duty alongwith street light poles for wire from junction box to light fittings & including fixing arrangement complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc should be deemed to be included in the unit rate quoted.
S & F in renewal for MCB SP 6 Amps, 230 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, part-I, complete all as specified & directed.
M & L for repairs to outdoor / indoor type Feeder Pillar box of any capacity / size by replacing pitted portion not exc 1 Sq Mtr with as per existing/suitable gauge of MS Sheet, cutting to shape, welding work, renewal of unserviceable door hinges and locking arrangement, necessary electrical connections etc and incl painting with two coats of synthetic enamel paint over and incl a coat of red oxide primer complete all as specified and directed.
S & F in renewal of Solar batteries for Solar PV Power System of rating 12 V, 200 Ah, with conatainer and lids made of Polypropylene Co Polymer of rating 12 V, 200 Ah, Manufactured with high corrosion resistant and robust spine technology with positive plate of tubular low antimony and negative plate flat pasted with Ah effciency of above 90% and Wh efficiency above 80% complete all as specified and directed. Make :- Luminous/Exide/SF Sonic/Amron.
S & F in renewal of Solar batteries of Integrated type Solar Light as per the capacity of the u/s lights and lithium ion battery 11.1/12.8 Volt, 15.4 Ah minimum with internal battery management circuit (BMS) having short circuit, deep discharge and over charge protection, setting parameters are LVD 8.5 Volt, HVD 12.6 Volt, suitable for (-) 20°C to (+) 60°C, suitable for existing 12W Integrated Solar Street Light complete all as specified and directed. Make :- Axxon/Bajaj/Philips.
S & F in renewal of Micro controller based charger controller cum driver for solar batteries of integrated type solar light with/without PIR motion sensor suitable for (-) 20°C to (+) 60°C with short circuit, over load protection, suitable for existing 12W Integrated Solar Street Light complete all as specified and directed. Make :- Axxon/Bajaj/Philips.
S & F in renewal of Solar PV Panels, Poly/Mono crystalline in the existing / shifted solar light poles with required cabling and clamping arrangement complete all as specified and directed of the following Watts :- Make : - Luminous/Microtek/Havells/CG.
75 Watts x 12 Volts
200 Watts x 12 Volts
S & F in renewal of aluminium cable lugs complete all as specified and directed of the following sizes :- Make : Dowell's/Jainson or equivalent.
25 Sqmm Size
35 Sqmm Size
50 Sqmm Size
70 Sqmm Size
S & F in renewal of aluminium crimping connectors complete all as specified and directed of the following sizes :- Make : Dowell's/Jainson or equivalent.
25 Sqmm Size
35 Sqmm Size
50 Sqmm Size
70 Sqmm Size
M & L for rectification of LT cable, fault existing/as and when occurs with diagonising equipments as applicable and by joining with suitable LT cable joint kit complete all as specified and directed. Note :- (i) Diagonising equipments, Skilled labour, Machinaries for excavation and re-filling earth work are to be provided/ arranged by the contractor at his expenses. (ii) If LT cable fault occurs in Road crossing then road cut surface to be made good as existing after rectification work. (iii) GI pipe utilized to cable protection under Road/ Over wall will be measured and paid respectively under appropriate item of this BOQ.
Supply, laying and fixing in renewal of GI pipe 50 mm bore light grade for protection of cable as in trenches/along pole / wall / laid under the road / laid under the floor etc.,or concealed in wall/floor or along poles or as street light poles or as mounting bracket, bent to shape with accessories such as bends / sockets / reducers/ saddle & including necessary threading / drilling works & including clamps complete all as specified and directed. Note :- Excavation & earth work shall be measured & paid for separately under respective item of this BOQ.
M & L for in re-positioning /re-aligning directional changes of security lights affected by high speed wind/ desert storm over the same existing poles in specific locations complete all as specified and directed. Note :- Skilled labour, tools as required shall be provided/ arranged by the contractor and the cost of it, shall be deemed to be included in the above item quoted rate.
M & L for in altering height of security light elevation over the same existing poles in specific locations complete all as specified and directed. Note :- (i) Skilled labour, tools as required shall be provided/ arranged by the contractor and the cost of it, shall be deemed to be included in the above item quoted rate. (ii) Copper cable whichever consumed shall be measured and paid respectively under appropriate item of this BOQ.
M & L for in removing and re-erecting of steel tubular security light poles/Solar Light Poles, tilted or fallen down due to gale/Desert Storm, in its same or new locations complete all as specified and directed. Note:- (i) Excavation and earth work, PCC etc shall be measured and paid for separately under respective items of BOQ. (ii) Cost of Machinery, Skilled labour, tools as required shall be provided/ arranged by the contractor and the cost of it, shall be deemed to be included in the above item quoted rate.
M & L for writing letters or figures (Block. Roman, Italic or Indian) height of serially painting numbers n exc. 30 cm on the Security light concrete / Steel tubular poles with yellow background and black letters of synthetic enamel paint 1st grade complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried directly (vertically) in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized strip 32 x 6mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling of old unserviceable earthing complete all as specified and directed. Note : (i) The cost of 7.5m earth lead /copper strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work, RCC & PCC etc are included in the quoted rate. (iii) On testing after completion, if the earth resistance less than 0.5 Ohms is not obtained earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
M/s Shiv Builder and Suppliers
KRISHNA CONSTRUCTION COMPANY
M/S SOLANKI GENERAL SUPPLIERS
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .