| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹26.2 L+₹1.2 L (4.84%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹28.9 L+₹3.9 L (15.6%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹29.2 L+₹4.3 L (17.1%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹29.7 L+₹4.8 L (19.1%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
25 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MANNING AND OPERATIONS AC PLANTS AT P 195 OF NAD STORE HOUSE AT MOV OLD SITE INCLUDING PREVENTIVE PERIODICAL MAINT OF AC PLANTS OF DIFFERENT CAPACITIES AT NAD AREA UNDER AGE E M NO II OF GE UTILITY II VISAKHAPATNAM
2021_MES_438153_1
8776
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer Utility-II Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-II
₹82,000
Yes
8 Jun 2021
27 Apr 2021
26 May 2021
27 Apr 2021
25 May 2021
13 May 2021
60 days
Amount
Manning, Operation and maintenance to Central AC Plant of Store House at MO (V) Old Site with one skilled operator per shift of 8 hours round the clock in 3 shifts a day including Sunday and holidays complete all as specified and directed by Engineer -in- Charge. Man power:- One skilled operator per shift of 08 hrs List of equipments:- [a] 3 x 90 TR Water Cooled AC Plant [b] Cooling Tower, connected pumps and pipes complete [c] AHUs alongwith ducting connections complete. [d] LT Electrical Panel & AMF Panel - 02 Nos [e] 500 KVA DG Set - 01 No.
Manning, Operation, maintenance of Fire Fighting Pump House (P-17 Bldg) at MO (V) Old Site, consisting of connected pipe line, including connected valves and various size of MS / DI / GI pipe line network for smooth operation round the clock in three shifts per day of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in-charge Man power:- One semi-skilled operator per shift of 08 hrs List of equipments:- [a] Fire main Pumpset - 01 Nos [b] DD Pumpset - 01 Nos [c] Jockey Pumpset - 01 Nos [d] Control Panels / Starter Panel - 01 No Note : Manning Covered under Sl No - 02 of BOQ shall commence from 01 Jul 2021.
Manning, Operation and maintenance to Central AC Plant at P-195 Bldg at NAD one skilled operator per shift of 8 hours round the clock in 3 shifts a day including Sunday and holidays complete all as specified and directed by Engineer -in- Charge. Man power:- One skilled operator per shift of 08 hrs List of equipments:- [a] 3 x 80 TR Water Cooled AC Plant [b] Cooling Tower, connected pumps and pipes complete [c] AHUs alongwith ducting connections complete. [d] LT Electrical Panel & AMF Panel - 02 Nos [e] 250 KVA DG Set - 01 No. Note : Manning Covered under Sl No - 03 of BOQ shall commence from 01 Aug 2021.
Note for item No.1 to 3 :- Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
(i) Cleaning the sorroundings of the pumps and replacing gland packing, greasing periodicaly for smooth functioning of the pumps and AC plants complete all as specified and directed by Engr-in-Charge is contractor's responsilbility. The rate quoted deemed to be inclusive of (a) Keeping neat and clean of complete installation area by grass cutting and removing the debris in & around premises upto 1.5 m from installation Bldg. (b) Keeping daily record of DG / Pumpset / AC Plant running hrs all as specified and directed by Engr-in-Charge . (c) Carrying out A check of DG set / Pumpset / AC Plant daily as per Manufacturer's manual. (d) Replacing of distilled water / battery electrolyte and charging of batteries as when required. (e) The installation will be handed over in operating staff on the commencement of contract through work order. (f) The operator shall ensure by trial run and be alert to run the DG Set and DD Pumps within 5 minutes of supply failure in case of manual operation / failure of auto mains.
(g) Diesel shall be issued by department as and when required as directed by Engineer-in-charge. The quoted rate is deemed to be inclusive of transporation of Diesel from store yard to work site. (h) Contractor shall have to intimate minimum 03 days in advance for issue of diesel. (j) The quoted rate is inclusive collecting and transportation of diesel from store yard of AGE E/M to work site, loading of diesel in the fuel tank regular checking of engine oil, battery electrolyte and radiator water level and rectifying minor defects such as Engine Air lock, tightening of loose bolts and nuts etc, which may develop during operation and relative parameters all as specified.
(k) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge. (b) The installation/plant room should be maintained neat and clean.
M & L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.
Supply, install, testing and commissioning of 24V, 180 AH sealed maintenance free generator starting system with SMPS charger, factory charged including terminal clamps, copper lead of suitable size / length, with battery stand including taking down unserviceable one from the DG Set complete all as directed. Model AX1013235 of Cummins Pulse Ultra Plus or equivalent in Exide / Amron.
M & L for replacement of battery lead sets of two (Red & Black) suitable for 180 to100 AH capacity up to 1.5 mtr long including GM terminals one end copper lug and other fixtures connecting both end with gun metal terminals as per existing all as specified.
Supply and replace Butterfly valves of cast iron 100/125 mm dia complete all as specified and as directed. Make: L&T/ ADVANCE/AUDCO/ KIRLOSKAR/ FOUNTAIN
Supply and replace MCCB, 3 Pole, 63 Amps, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed.
Supply and replace MCCB, 3 Pole, 100 Amps, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed.
Supply and replace MCCB, 4 Pole, 125 Amps, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed.
Supply and replace MCCB, 4 Pole, 250 Amps, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed.
Supply and replace MCCB, 4 Pole, 400 Amps, 50 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed.
Supply and replace bimetal over load relay of 16/20 Amps capacity complete all as specified and as directed.
Supply and replaceg bimetal over load relay of 32/63 Amps capacity complete all as specified and as directed.
Supply and replace Power Contactor of MNX-9, 25 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 1NO + 1NC complete all as specified and as directed.
Supply and replace Power Contactor of MNX-18, 30 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 1NO + 1NC complete all as specified and as directed.
Supply and replace Power Contactor of MNX-25, 45 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 2 NO + 2 NC complete all as specified and as directed.
Supply and replace Power Contactor of MNX-32, 55 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 2 NO + 2 NC complete all as specified and as directed.
Supply and replace Power Contactor of MNX-50, 85 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 2 NO + 2 NC complete all as specified and as directed.
Supply and replace MCB SP, 6 to 32 Amps, 10 kA, AC, 240 V, 50 Hz complete all as specified
Supply and replace MCB SPN, 20 to 32 Amps, 10 kA, AC, 240 V, 50 Hz complete all as specified
Supply and replace MCB TP, 6 to 32 Amps, 10 kA, AC, 415 V, 50 Hz complete all as specified
Supply and replace MCB TPN, 20 to 40 Amps, 10 kA, AC, 415 V, 50 Hz complete all as specified.
Supply and replace "V" belt for power transmission of any type and size as per sample and site reqmt complete all as specified and directed
Supply & Fixing in replacement of pre-filter, cleanable type, made of non woven synthetic media with GI frame, Box / Bag type, having efficiency 90% down to 10 microns, of existing shape and size complete all as specified & directed by Engr-in-Charge. Make : Thermadyne / Spectrum / Puromatic / Athlete.
Supply & Fixing in replacement of MICRO-VEE 5 micron fine-filter, cleanable type, made of non woven synthetic media with GI frame, Box / Bag type, having efficiency 97% down to 3 microns, of existing shape and size complete all as specified & directed. Make : Thermadyne / Spectrum / Puromatic / Athlete.
M&L for carrying out leak test for Ductable package/split AC plants of capacity upto 5.5 TR using nitrogen gas and rectifying the leakages, arresting the leakages, including charging gas, testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note:- (i) Necessary copper pipes, welding works are deemed to be included in the quoted rate. (ii) Refrigerant gas shall be measured and paid separately.
All as per SL item No.27 above but 7.5/8.5 TR capacity.
All as per SL item No.27 above but 20 TR capacity condensor/ compressor.
Supply only refrigerant gas 134A Make:- Floron/Mafron
Supply only refrigerant gas R-410A/407/404A Make:- Floron/Mafron
Supply only refrigerant gas R-22. Make:- Floron/Mafron
Supply only Nitrogen gas for leak test
Supply only compressor oil. Make: Veedol 68/Sheetal N-68
S & F Rotational Moulded Polythene HDPE Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F Rotational Moulded Polythene HDPE Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 2000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
Supply & Replace ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore with minimum weight of 210 grams all as specified.
Supply & Replace ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm bore with minimum weight of 210 grams all as specified.
Supply & Replace ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 40 mm bore with minimum weight of 210 grams all as specified.
S & F in replacement PP-R, 3- layer concealed pipes of outer dia 40 mm, SDR 7.4 (PN16) UV stabilized, antimicrobial fusion welded having thermal stability for hot & cold water supply with all fittings / fixtures laid in trenches / on walls / under floor / road complete all as specified and as directed.
S & F in replacement PP-R, 3- layer concealed pipes of outer dia 50 mm, SDR 7.4 (PN16) UV stabilized, antimicrobial fusion welded having thermal stability for hot & cold water supply with all fittings / fixtures laid in trenches / on walls / under floor / road complete all as specified and directed.
S & F in replacement PP-R, 3- layer concealed pipes of outer dia 63 mm, SDR 7.4 (PN16) UV stabilized, antimicrobial fusion welded having thermal stability for hot & cold water supply with all fittings / fixtures laid in trenches / on walls / under floor / road complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for laying of cables / pipes etc and getting out in soft / lose soil complete all as specified.
Returning, filling in including spreading levelling watering and well ramming in layers not exc 25 cm in any type of soil.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed.
Jungle / Area Cleaning by using JCB / BOBCAT for removing bushes / thick vegetation around the pump house, installations, along the pipelines to find out the leakages, levelling the area without damaging the pipelines / Cable network / Pedestals of pipelines / buildings including disposal of the vegetation / debris material up to a distance not exceeding 50 m complete all as specified and directed by Engineer-in-Charge.
M&L in repairs Synthetic mat (rubber matting) suitable for 11000 Volts electrical grade 2mx1mx19mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed.
GANGA SURAJ ENTERPRISES
GS ENGINEERS
GVR CONSTRUCTIONS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
Sri Surya Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .