Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Not qualified |
| 4 | Rejected-Technical | Rejected-Technical Not qualified |
| 5 | Rejected-Technical AKASH KUNJ KANULAL ROAD MITHAPUR PATNA BIHAR 800001 | PATNA | BIHAR | 800001 | Rejected-Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
11 Jul 2022, 11:30 amClosed
COMMANDANT 3 SIGNAL BN,CRPF
COMMANDANT 3 SIGNAL BN, CENTRAL RESERVE POLICE FORCE, SECTOR-V, SALT LAKE, KOLKATA 91 (W.B)
Repair and maintenance works and interior and exterior painting, replacement of damaged CGI tin sheet and false ceiling panel, plinth protection and electrical repair works etc for Mens club at 3 Signal Bn, CRPF, Kolkata (W.B.).
2022_CRPF_695900_1
B.V-1/2022-23-Bldg-3 Signal-Minor Works
Open Tender
Civil Works
Item Rate
60 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹20,000
29 Jul 2022
20 Jun 2022
12 Jul 2022
20 Jun 2022
11 Jul 2022
20 Jun 2022
Amount
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Two coats
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Polishing on wood work with readymade wax polish of approved brand and manufacture :
Old work
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work
Painting with aluminium paint of approved brand and manufacture to give an even shade:
One or more coats on old work
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
G.S. Sheet
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
1.00 mm thick with zinc coating not less than 275 gm/m²
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
20 mm cement plaster
Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and L-sections suitably fixed according to tile size as per direction of Engineer-in-charge.
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :
Thickness above 10 mm up to 25 mm
Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface
12 mm thick
Re-Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Painting of ceiling fan , tube light frame in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
Supplying and fixing 6amp. MCB
Supplying and fixing fan regulator 2000 Watt including old regulator dismantling as per direction of Engineer-in-charge.
Replacement /Supplying and fixing LED ceiling light 15watt with same specifications as required.
Repair / overhauling of wall mounted fan by rewinding, capacitor etc.and refixing of repaired wall mounted fan with cleaning and repainting ,all complete as per the direction of the Engineer-in-charge
G. C. ENTERPRISE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .