Loading…
Loading…
Tender Value
₹2.2 L
EMD Value
₹5,462
Closing Date
25 Sept 2026, 5:00 pmClosed
ASSI.EXECUTIVE ENGINEER
ASSI.EXECUTIVE ENGINEER LID EW DIVISION IDUKKI GP PAINAVU
GENERAL-IDP works -2026-27, Project Number SO 171/27-Konnathadi GP - Mukkadam IHDP Nagar DWSS-Providing Motor Pumpset-General Electrical Work
2026_LSGD_869144_20
05/T/AEE/LID EW/IDK/2026-2027
Open Tender
Electrical Works
Item Rate
180 days
KONNATHADY GP
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹5,462
Yes
25 Sept 2026
11 Sept 2026
28 Sept 2026
11 Sept 2026
25 Sept 2026
11 Sept 2026
11 Sept 2026 - 25 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing Pump Set - | |||||
| 1.001 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 4 | point | - | - |
| 1.002 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 1 | point | - | - |
| 1.003 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 1 | each | - | - |
| 1.004 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps | 1.5 | metre | - | - |
| 1.005 | OD177525/2026-2027:Supply, conveyance, installation, testing and commissioning of Bulk head light fittings with 7/9
W LED bulb directly on wall including giving connections with required length of 16/0.20mm 3
core round copper conductor flex wire conforming to relevant ISS making good the damages,
colour washing etc as required. | 3 | each | - | - |
| 1.006 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | 1 | each | - | - |
| 1.007 | OD177536/2026-2027:Supply and fixing angle / straight brass lined skirt type, backelite batten holder with 7/9W LED
and plastic
shade and giving connection etc as required | 1 | each | - | - |
| 1.008 | 90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm | 25 | metre | - | - |
| 1.009 | OD177530/2026-2027: Supply, conveyance, errection, testing and commissioning of : HEAD RANG- 90 TO 240 MTR, DISCHARGE- 200 TO 80 LPM, OUT LET - 2 INCH DECAN EKKI 10HP 16 STAGE SUBMERSABLE BOREWEL Pump set working on 3 phase 415 V, suitably mounted on proposed 50 mm GI pipe etc as required or equallant make. | 1 | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.44 MB
BOQ_1472623.xls
BOQ • 0.33 MB
NIT.pdf
Tender Documents • 0.02 MB
BID.pdf
Additional Documents • 1.63 MB
CORRIN.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .