Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.3 LAccepted-Finance 408 409 HAASH BUSINESS CENTER NR ANKUR SCHOOL FATEHPURA PALDI AHMEDABAD 380007 | AHMADABAD | GUJARAT | 380007 | L-1 | Accepted-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY | |
| 2 | L-2₹7.5 L+₹22,712 (3.13%)Rejected-Finance | L-2 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY | |
| 3 | L-3₹7.6 L+₹30,790 (4.25%)Rejected-Finance BYPASS ROAD BESIDE YUG BAJAJ SHOWROOM GARIBICHOK PORBANDAR 360577 | PORBANDAR | GUJARAT | 360577 | L-3 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY | |
| 4 | L-4₹7.9 L+₹62,942 (8.68%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L-4 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY | |
| 5 | L-5₹8.3 L+₹1.0 L (14.0%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-5 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY |
Tender Value
₹9.3 L
Closing Date
29 Jan 2021, 6:00 pmClosed
AGM(E-E)
Engg.Office, AAI, C.A.Porbandar
Supply and laying of HT cable between open yard DP structure to Power House at C A Porbandar.
2020_AAI_64590_2
AAI/POR/AGM(E-E)/e-NIT-5/20-21
Open Tender
Electrical Works
Item Rate
90 days
Porbandar Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
Exempted
17 Mar 2021
20 Jan 2021
2 Feb 2021
21 Jan 2021
29 Jan 2021
21 Jan 2021
21 Jan 2021 - 25 Jan 2021
Amount
Supply of following size 11 KV grade XLPE insulated and overall PVC sheathed aluminium conductor armoured cable, confirming to IS:7098 (Part -II) 1985 with upto date amendments and as per attached technical specifications. (Make - As per attached list of approved makes).....(a) 3 core x 185 Sq.mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 160 mm dia (OD-160 mm & ID-135 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 185 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Upto 185 sqmm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 185 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 185 sq. mm
Supply Installation Testing & Commissioning of 11 KV pin type insulator confirming to IS : 731-1971 suitable for existing 11 KV DP structure complete with all necessary accessories as required as approved by E.I.C.
Supply Installation Testing & Commissioning of 11 KV disk type insulator confirming to IS : 731-1971 suitable for existing 11 KV DP structure complete with all necessary accessories as required as approved by E.I.C.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
ABHISHEK ASSOCIATES
Unicon Engineering Co
Techno Electricals
Manish Electricals
Digja Infrastructure LLP
SHAKTI TECHNO FAB PRODUCTS
Mona Generator Services Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .