Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3,690
Closing Date
19 Jun 2026, 12:00 pm
O/O The AE/BESD
Purta Bhavan, 4th Floor, Kachari Raod, Balurghat, Dakdhin Dinajpur, Pin-733101
Repair of AC machines (capacity 11TR,5.5TR) at Blood bank at Balurghat District Hospital,in the Dist. Of Dakshin Dinajpur, Balurghat.
2026_WBPWD_5015025_1
WBPWDTE/AE/BESD/e-NIQ-07 of 2026-27
Open Tender
Electrical Work/ Equipment
15 days
Balurghat
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,690
5 Jun 2026
5 Jun 2026
22 Jun 2026
5 Jun 2026
19 Jun 2026
8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Cost of through over-howling and cleaning of the 5.5 Ton Ductable A.C. hanging part by part open of the condenser coil body.Compresser unit, copper tube & necessary "U" band by through air presser and help of special type chemical,detergent,water,tools,tackles and skilled labor etc. and re-filtting the same.Complete the job in all respect as per direction of E.I.C. | |||||
| 1.01 | Indoor unit (Cooling coil) | 1 | Unit | - | - |
| 1.02 | Outdoor unit (Condenser coil) | 1 | Unit | - | - |
| 2Cost of through over-howling and cleaning of the 11 Ton Ductable A.C. hanging part by part open of the condenser coil body. Compresser unit, copper tube & necessary "U" band by through air presser and help of special type chemical,detergent,water,tools,tackles and skilled labor etc. and re-fitting the same.Complete the job in all respect as per direction of E.I.C. | |||||
| 2.01 | Indoor unit (Cooling coil) | 2 | Unit | - | - |
| 2.02 | Outdoor unit (Condenser coil) | 2 | Unit | - | - |
| 3 | Charges Materia with labour for 1 Leak testing by Nitrogen gas pressure time to time after leak detection point Blazing & puring the Refrigerant unit by gas pressure for removing the moisture and dust from inside the system & hold on Nitrogen gas pressure. | 3 | Unit | - | - |
| 4 | Labour charges for vaccuamissing for stay of vaccum 24 hours after that gas charging connisoning observation (5.5 TR = 1 unit total 11 TR = unit 1 NO Refrigeratation Circuit) running of machines & temperature setting Etc as per direction of E.IC. | 1 | Unit | - | - |
| 5 | Supply of Refrigerant R 410 A | 25 | Kg | - | - |
| 6 | Supply and Fixing 11TR outdoor unit fan blade size 24" | 2 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
Tendernotice_2.pdf
PDF • 0.96 MB
Tendernotice_3.pdf
PDF • 1.24 MB
BOQ_5083521.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid