Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | ₹10.3 L Quoted ₹10.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹11.1 L+₹24,845 (2.29%)Rejected-AOC | ₹11.1 L+₹24,845 (2.29%) | L2 | Rejected-AOC Become L2 |
| 3 | L3₹11.5 L+₹58,819 (5.41%)Rejected-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹11.5 L+₹58,819 (5.41%) | L3 | Rejected-AOC Become L3 |
| 4 | L4₹12.0 L+₹1.1 L (10.2%)Rejected-AOC NIL | ₹12.0 L+₹1.1 L (10.2%) | L4 | Rejected-AOC Become L4 |
| 5 | L5₹13.4 L+₹2.5 L (23.0%)Rejected-AOC | ₹13.4 L+₹2.5 L (23.0%) | L5 | Rejected-AOC Become L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Jun 2020, 6:00 pmClosed
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
Repair/maintenance of internal electrification and other allied works at zone 2 and 4 under GE (S) Tezpur
2020_MES_345856_1
8494
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹30,000
Yes
22 Jul 2020
19 May 2020
18 Jun 2020
19 May 2020
16 Jun 2020
2 Jun 2020
Amount
M&L for rewinding of ceiling fan,1200mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings both complete all as specified and directed
M&L for rewinding of Exhaust fan 300mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings complete all as specified and directed
M&L for rewinding of Exhaust fan 400mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings complete all as specified and directed
M&L for painting of fan (ceiling fan / exhaust fan/wall mounted fan ) any sweep with applying one coat of synthetic enamel paint (Ceiling Fan -White Paint and Exhaust fan - Gray Paint ) by spray machine including preparation of old painted surfaces with filling of cavity by filler with and including writting of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern complete all as specified and directed.
Supply and Fix louver shutter (with Mosquito net made out Aluminium wire cloth 0.36 mm nominal dia ) made out GI sheet (Thickness of louver shutter Body 1mm ,shutter Fins 0.5 mm fixed with 3 mm GI wire ) for Exhaust fan 300/400 mm sweep including proper fixing with screw in wall at existing Hole including taking down old unsv louver shutter complete all as specified and directed.
S & F Ball bearing (Bearing No- 6201/6202) of ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv bearing complete all as specified and directed.
S & F Capacitor( 2.5-4) MFD for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv capacitor.
S & F Down rod 15mm bore medium grade GI pipe including cut in required length and drilled as per existing size including taking down old unsv down rod complete all as specified and directed.
S & F Fan blade for Ceiling fan of 1200mm sweep of white colour including taking down old unsv fan blade complete all as specified and drected.
Taking down old Unsv DB of any type & any capacity complete all as specified and directed
S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed.
S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed.
S & F Power line vertical type TPN DB double door 4 way, IP 43 suitable for MCCB 100 amps CRCA sheet metal enclouser with detachable gland plates for flush / surface mounting with bus bar neutral link and Earth Bar in concealed and all disturbed surfaces of wall shall be made good to match the existing wall finishes complete all as specified and directed.
S&F in replacement of metering Panel, powder coated factory made for mounting Electric meter at stair case for 4 electric meters, box should be cubical indoor type modular design of not less than 900 mm x 900mm x200mm , with 2mm thick CRCA sheet steel with IP 52 tested, fabricated by welded frame construction with CRCA frame section, compartmentalised (Modular) desing. The cable entry shall be from the bottom and top of the panel provided with suitable dia brass gland plates for provisioning specific bending radius for cable. The panel shall have opening arrangements front side mounted on hinges as and fitting fixure in wall as specified and directed.
Taking down old Unsv MCB/MCCB/RCBOs of any type & any capacity complete all as specified and directed
S & F MCB SP 6 to 32 Amp, B series , 230 Volts complete all as specified and directed.
S & F MCB DP 6 to 32 Amps, B series, 230 Volts complete all as specified and directed .
S & F MCB DP 40-63 Amps, B series, 230 Volts complete all as specified and directed.
S & F MCB TPN 40-63 Amps, B series, 10 KA "B" series 415 Volt complete all as specified and directed.
S & F MCCB 4 Pole 415V Fixed type 25-100A with breaking capicity 16 KA complete all as specified and directed.
Taking down the existing U S wiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with conduit/casing caping, along with all connected accessories complete all as directed.
M&L for point wiring complete for One light point with 1.5 Sqmm single core multistranded copper conductor FR PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through PVC casing caping including provn of 1.5 sqmm single core multistranded copper conductor FR PVC insulated and unsheathed as earth wire continuity including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition) complete all as specified and directed.
Ditto as per Item No 22 above but for one fan / Exhaust fan point
Ditto as per Item No 22 above but for One 3 pin 5 Amp socket outlet on the same board
Ditto as per Item No 22 above but for One 3 pin 5 Amps socket out let on independent board
Ditto as per Item No 22 above but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
Ditto as per Item No 22 above but for one bell point controlled by one 5 amp switch
Ditto as per Item No 22 above but for one light point controlled by two two way switches
S & F in repair electronic fan regulator,100W ,230V ,50Hz stepped socket type for ceiling fan complete all as specified.
S&F in repair switch piano type, 5 Amp. SP, one way all as directed/ specified.
S&F in repair switch piano type, 15 Amp. SP, one way all as directed/ specified.
S&F in repair switch socket outlet, 2 in one 5 pin, 5 Amp, piano type all as directed.
S&F in repair switch socket combination 2 in 1, 6 pin 5 and 15 Amp flush type universal all as directed/ specified.
S&F in repair switch bell push, flush type, 5 Amp all as directed/ specified.
S&F in repair bell, AC, 230 V, SP, ding dong type all as directed & specified.
S&F in repair of Ceiling rose 3 phase, PVC/ Polycarbonate body all as directed/ specified.
S&F in repair switch two way switch flush type, 5 Amp all as directed/ specified.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size not less than 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size not less than 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size not less than 200 mm x 105 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size not less than 250 mm x 200 mm and 50 mm deep complete all as specified and directed.
M & L for Point wiring for one light point with 1.5 sqmm PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and existing non metallic PVC rigid conduit and conduit accessories, medium grade, ISI marking, concealed with provn of modular metal flush box and Modular white Cover Plate with Frame for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable FR grade as in earth wire for continuity and connecting to earth dolly for one light point controlled by one switch complete including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the wall (wash/paint/distemper) wherever required(as per the existing condition) all as specified and directed Note -modular metal flush box and Modular white Cover Plate with Frame shall be measured and paid for seperately under relevent item. wire make- polycab/havells
Ditto as per Item No 42 above but for one fan / Exhaust fan point
Ditto asper Item No 42 above but for One 3 pin 5 Amp socket outlet on the same board
Ditto as per Item No 42 above but for One 3 pin 5 Amps socket out let on independent board
Ditto as per Item No 42 above but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
Ditto as per Item No 42 above but for one bell point controlled by one, one 5 amp switch
S&F modular metal flush box of module 1/3/2 flush ISI marked make - Havells or equivalent make of Anchor all as specified and directed.
S&F modular metal flush box of module 4 flush ISI marked make - Havells or equivalent make of Anchor all as specified and directed.
S&F modular metal flush box of module 6 /8flush ISI marked make - Havells or equivalent make of Anchor all as specified and directed.
S&F modular white cover plate with frame of module 1 flush ISI marked Havells or equivalent make of Anchor all as specified and directed.
S&F modular white cover plate with frame of module 2/3flush ISI marked Havells or equivalent make of Anchor all as specified and directed.
S&F modular white cover plate with frame of module 4 flush ISI marked Havells or equivalent make of Anchor all as specified and directed.
S&F modular white cover plate with frame of module 6 ISI marked Havells or equivalent make of Anchor all as specified and directed.
S&F modular white cover plate with frame 8 module ISI marked make - Havells or equivalent make of Anchor all as specified and directed.
S&F modular blank plate module 1 all as specified and directed.
S&F in repair modular switch flush type, 6 Amp. SP, one way ,1 module all as directed specified.
S&F in repair modular socket outlet, 3 pin, 6 Amp, flush type 2 module all as directed/ specified.
S&F in repair modular switch, 16 Amp flush type 1 module all as directed/ specified.
S&F in repair modular socket outlet, 3 pin, 6/16 Amp flush type 2 module all as directed/ specified.
S&F in repair modular bell push, flush type, 5 Amp,1 module all as directed/ specified.
S&F in repair modular Fan Regulator step type 2 module ,120W all as directed/ specified.
Taking down old unsv submain wiring of any size complete all as specified and directed
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
Supply and fixing single phase Electronic tamper proof energy meters with LCD display of 10-60A capacity 230V AC 50Hz ISI marked and celing the meter(Top & Bottom covers) with suitable lead wire and connecting up incomming and outgoing cable connetions to meter including taking down old unsv meter and taking to MES Store including earthing of meter including testing and commisioning complete.
S& F ceiling fan of sweep not less than 1200mm with hanger including taking down existing old unseviceable ceiling fan and taking to MES Store as specified and directed.
Taking down old unsv LED lights of any wattage , any type including all its accessories complete all as specified and directed.
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution not less than 9W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution not less than 20W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per
S & F not less than 12 Watt LED fitting surface mounted , 6500k, colour temp >= 5700K with die cast body with premier diffuser ensuring glare free light including taking down old unserviceable type downlighter all as specified and directed by.
S & F surface accessory module for 12 Watt LED fitting with all its accessories including taking down old unserviceable module all as specified and directed .
Supply and fix Heating element of 1500/2000 watts suitable for 25 ltrs capacity water heater including taking down old unsv element complete all as specified and directed.
S & F Thermostat of range 0-80 degree Celsius suitable for 25 Ltrs water heater including taking down old unsv thermostat complete all as specified and directed.
M/S Manjit Singh
MAHANTA ENTERPRISES
M/s. M. G. Babloo Das
M/S GOSWAMI ENGINEERING
United Traders
KIRTEE KAMAL TAMULI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .