Loading…
Loading…
Tender Value
₹66.9 L
EMD Value
₹67,000
Closing Date
27 Jan 2026, 6:00 pmClosed
Superintending Engineer, Project Implementation Unit, Health & Family Welfare Department.
Supply, Installation, Testing and Commissioning of Semi Modular Operation Theatre At.SDH Bardoli & SDH Mandvi Di.Surat
251139
2025-26/103/04
Open
Civil Works - Buildings
Surat
1 document required · 1 mandatory
₹2,400
Yes
PIU-General Fund A/c 11-114
₹67,000
Yes
8 Dec 2025
8 Dec 2025
8 Dec 2025
27 Jan 2026
8 Dec 2025
Name of Work :Supply, Installation, Testing and Commissioning of Semi Modular Operation Theatre At.SDH Bardoli & SDH Mandvi Di.Surat
Estimated Estimated Rates Total Amount
Estimated Estimated Rates Total Amount
may be Item Of Work Unit may be more
more or or less
less In Figure In word
Supply, Installation, Testing and Commissioning of 50 mm thick Pre Fabricated Modular Operation Theater Panels
(Walls and Ceiling) made out Polyurethane foam injected at 40 Kg/m3 sandwiched between
0.8 mm thick GP and SP sheet on front side and 0.5 mm GP and SP/PPGI sheet on back-side. The inner surface walls
be fixed to the bricks wall with essential support. There will be minimum possible cavity/gap in between solid and steel
walls and will be variable to suit the architects lay out for the flush mounting of the equipments. The wall and ceiling
panels must comply with necessary provision of to JIS Z 2801/ISO 22196, BS EN 1363-1:2020, EN 1363-2:1999, EN
52210-2:1984-08, DIN 4102-1, Class A2. Any Third-party compliance certificate mandatory. Panel should be covered
6550.00 Rupees Six Thousand Five Hundred Fifty Only Sq Mtrs.
with protective sheath of 300 d.f.t Anti-bacterial Paint having undergone Washability/Water resistance Test JIS K
5663.7.12, permeability test less than 200 unit of permeability, Anti-bacterial effect against staphyloccoccus aureus,
Escherichia coli (via HALO test) and safety and causative agents such as formaldehyde, toluene, xylene,
paradichlorobenzene etc. Third party (NABL approved Lab) certification for EGP and thickness test certificate to be
at time of supply.
The flooring within the surgical theatre should consist of a minimum of 2mm thick antistatic seamless PVC, ensuring
durability and safety. This floor should be smooth, non-slip, and made from an impervious material with sufficient
conductivity to dissipate static electricity effectively, yet not so conductive as to risk electric shock to personnel. The
PVC used should be of very high quality, particularly designed for electrostatic charge dissipation, and should not be
less than 2 mm in thickness. The installation process should utilize continuous rolls, and joints should be seamlessly
welded using special PVC thermal welding units with welding bars of the same color to ensure uniformity and prevent
contamination. The sheets should be highly durable, capable of resisting shocks, indentations, and scratches. The
conductive material should be uniformly impregnated within the PVC as grains to enhance its antistatic properties.
Additionally, the flooring should be inert to body fluids, chemicals, and disinfectants, and remain unaffected by
temperature variations typical within an operating theatre. It should efficiently discharge electric charges up to 2 kV,
and the electrical resistance (point to ground) should be maintained within 2.5x10^4 to 5x10^6 ohms, ensuring no
2 78.90 buildup of electrical charge beyond 100 volts. Floor installation should be performed by skilled workers from 4250.00 Rupees Four Thousand Two Hundred Fifty Only Sq Mtrs.
accredited agencies authorized by the PVC sheet supplier. The installation should include a conductive copper grid
beneath the PVC sheet, supported by liquid epoxy compounds to create a uniform and level surface. Copper strips
should be made visible by grinding and not project more than 0.5mm above the floor level to prevent damage to the
PVC sheet, with one earthing lead brought out from every 150 sq.ft area and attached to the main earthing strip/ground.
The flooring should also be mechanically shockproof, scratchproof, flame retardant, and antimicrobial. Corners of the
flooring should be uniformly curved, and a concealed cove-former (aluminium) should overlap the wall panel to a
height of approximately 25mm and be sealed perfectly and uniformly. Before laying the PVC, suitable self-leveling
compounds should be used to prevent any undulations within the operating theatre. The final surface should be non-
corrosive to biological fluids and detergents, with a color that is uniform, pleasant, and matching with the ambience as
approved by the respective consignee.
SB Semo modular OT Page
Estimated Estimated Rates Total Amount
Estimated Estimated Rates Total Amount
may be Item Of Work Unit may be more
more or or less
less In Figure In word
The door to the surgical theatre should be a hermetically sealed, single sliding door measuring 2.1 meters in height and
meters in width. The door should be equipped with a controller capable of being operated by elbow switches, foot switches, and
a touchless sensor, providing multiple, accessible control options. The track for the door should be made from stainless steel or
aluminum, with the running surface for the top rollers angled appropriately to minimize resistance and facilitate smoother
movement. The door leaf should be suspended using high-quality hard plastic rollers with double bearings at the top. These
rollers should run under the stainless steel or aluminum track to ensure smooth and noiseless operation. The opening and closing
mechanisms of the door should be controlled by a microprocessor for precise electromechanical movement. The material of the
door should be either SMS or HPL, with a color that matches the interior design. The door should be designed to be strong yet
lightweight for ease of use. In case the automatic mechanism fails, the door should still be able to open and close effortlessly
manually. The handle of the door should be made from stainless steel with a matte finish and equipped with a high-quality
cylindrical or ESPg lock for security. The door leaf should incorporate a high-quality synthetic rubber gasket with long
durability to ensure hermetic sealing and maintain a 99.99% air tightness at a minimum pressure of 75Pa. The floor on either
side of the door should be perfectly level, with a maximum permissible difference of +1mm, to avoid any tripping hazards or
3 2.00 unsealed gaps. The overall thickness of the finished door should range from 30-60mm, with the inner part of the door filled with 295000.00 Rupees Two Lakh NinetyFive Thousand Only Nos.
CFC-free polyurethane foam, approximately 48mm thick, sealed airtight to block any microbial ingress. The door and its controls
should comply with IEE regulations, utilizing DC brushless or PMDC motors that are effectively isolated from mains power to
ensure safety and reliability. Additionally, the door should include a vision window measuring 300mm x 300mm, featuring
double-glazed panels that are hermetically sealed to maintain the integrity of the seal.
The movement of the door should be as quiet as possible, and the time to start moving after
receiving a signal should be adjustable between 0.5 to 20 seconds.The door controller should be CE marked, BIS certified, or
IEC 60601 certified to meet international and national safety standards. A test certificate for the hermetically sealed door frame
should be included in the pre-dispatch documents to verify compliance with the specified standards and functionality.
Hatch boxes should be provided in each operating theater to facilitate the safe and efficient removal of waste materials
to the dirty linen area or adjacent corridor. Each hatch box should be equipped with two doors, operated electrically or
motorized, designed such that only one door can be opened at a time to prevent cross-contamination. UV lighting
4 2.00 should be installed to ensure sterilization and should remain on when both doors are closed, automatically turning off 115000.00 Rupees One Lakh Fifteen Thousand Only Nos.
when either door is opened. Indicators should be provided on both sides of the operating theater to monitor the door
open/close status. The material of the hatch box should also be SS304 grade stainless steel, with a minimum size of
Supply, Installation, Testing and Commissioning of Storage Units - Storage units should be constructed with same
material, as wall and ceiling panels. The shelves, made of glass and, should be removable for cleaning. The unit should
5 3.00 be divided into two or more parts, each with individual glass doors equipped with a high-quality locking system. The 85000.00 Rupees EightyFive Thousand Only Nos.
overall size of the storage unit should
be approximately 200 cm (H) x 120 cm (W) x 35 cm (D).
SB Semo modular OT Page
Estimated Estimated Rates Total Amount
Estimated Estimated Rates Total Amount
may be Item Of Work Unit may be more
more or or less
less In Figure In word
Supply, Installation, Testing and Commissioning of Double-Bay Scrub Sink - The scrub station should be compact,
designed for use in the OT complex, and facilitate pre-procedural scrubbing. It should be made from heavy gauge type
304 stainless steel with a minimum thickness of 1.5mm and feature seamless welded construction polished to a satin
finish. The scrub sink should have a front access panel for easy maintenance of water control valves, waste
6 1.00 connections, stoppers, and strainers. Hands-free operation should be enabled through infrared sensors with 126000.00 Rupees One Lakh TwentySix Thousand Only Nos.
programmable adjustments. Thermostatic mixing valve control should maintain constant water temperature and be
located behind the access panel. Timing should be adjustable to meet individual usage requirements, and units should
have reduced anti-splash fronts. An additional knee/foot-operated switch should also be provided for enhanced
AIR HENDALING UNIT Make:KrVelocity: Not More Then 10 mt/second. , Canvass Connection-Heavy duty, non
partical shreding,Fire Retardentuger,Nikotra only , Type: PLUG,Drirect Driven,Dynamically Balanced Selection of fan-
Should run comfortably at 50 HZ at rated capecity. Motor Make:Siemence,B.B,Crompton,ABB , Type:TEFC, IP:55,
Foot Mounted, VFD compitable and I2 generation Safety: Motor should have interlocked with AHU Motor
door/excess/Fire DamperType-TWO TIRE, Floor Mounted , Inner const.:0.6mm plain G.I , Outer const.:0.8 mm G.I. Rupees Twelve Lakh TwentyFive Thousand
7 2.00 Pre coated / Powder coated Thickness of Insulation: 25mm,PUF injected having density 40 to 42 kg/m3. ,Colour:As 1225000.00 job
approved by CLIENT CONDENSING UNIT :
Condensing unit for AHU with all assesories and instalation (Copper pipie provide 3 mtr Only Extra will charged
extra) consider 1200 sqfeet insulation and ducting
Double Dome OT Light with Ceiling mounted Double Dome LED OT lights having following features and enclosed
technical specifications, having Mobile App Connectivity, Battery Backup
-Light intensity Ec - 160 000 & 160 000 lux, - Light intensity adjustment - 10 – 100% (using Digital Capacitive Touch
(Fully Remote Controlled)
- Color temperature Tc (with adjustment)
-Light field diameter d10 at Ec - 100 - 150 mm
-Working range - 1 m
8 2.00 390000.00 Rupees Three Lakh Ninety Thousand Only Nos.
-Color rendering index 93Ra
- Focusing Preset: Adjustable
- LED Average life - 50000-60000 hrs
- Diameter of Light - not less than 650 mm per dome
- Power Consumption - not more than 120W
OT Light should be BIS marked; manufacturer should have CDSCO License for this product under Class A, Compliant
to IEC standards such as IEC60601-1:2005+A2:2020, IEC 60601-2-41:201 (Relevant Test Certificates to be submitted
with Bid) Clause-wise Technical Compliance to be
SB Semo modular OT Page
Estimated Estimated Rates Total Amount
Estimated Estimated Rates Total Amount
may be Item Of Work Unit may be more
more or or less
less In Figure In word
Single-arm surgery/anesthesia pendant designed for Operating Theatres should feature a compact, modular
configuration to meet the precise requirements of hospitals, enabling customization to suit specific operational needs of
both Operating Theatres and Intensive Care Units. It should be equipped with robust ceiling support capable of
mounting a selection of arms. The extension arm, pivotal for functionality, should allow horizontal movement with a
radius of 800-900mm and provide a level rotation ranging from 0 to 330/340 degrees, with both the extension arm and
terminal box designed to rotate together and independently for maximum versatility. The pendant should support a net
loading capacity of min. 100 kg, accommodating a variety of medical instruments and devices securely. For medical
and electrical services, it should offer configurations that include at least two oxygen outlets, two vacuum outlets, one
medical air, one medical air at 7 bar, and an optional nitrous oxide outlet (In-scope of MGPS vendor) Additionally,
9 2.00 there should be six main sockets, each capable of supporting 5 to 15 amps, conforming to universal standards to 284000.00 Rupees Two Lakh EightyFour Thousand Only Nos.
facilitate the operation of various medical and electronic devices. In terms of materials and construction, the pendant
should be crafted from high-strength aluminum alloy with a sealed design to enhance durability and maintain sterile
conditions. The arm itself should be made from high-density aluminum alloy extrusion, ensuring both strength and
reliability. Installation of the pendant should be ceiling-mounted to provide a reliable and firm setup, optimizing space
usage in the Operating Theatre or ICU while seamlessly integrating with existing medical systems for managing
medical gas, electrical services, data communication, and equipment. Additionally, the pendant should include practical
features such as a stainless steel IV pole and a ward vacuum unit clamp to further enhance its utility in a medical
setting. With a net weight of approximately 105 kg, accessible by the equipment carrier, the pendant should be robust
yet manageable, ensuring it meets the rigorous demands of modern medical environments.
In Words :- Rupees SixtySix Lakh NinetyThree Thousand Nine Hundred SeventyFour Only
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in
S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost
of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender. Input rate is Rs. 5234/- per MT.
5 GST extra applicable in case of work based on SOR 2023-24 only.
6 Servicable materials available after Demolishing / Dismentalling any item should be hand over to the concerned as per instruction of PIU engineer in charge.
Dy. Executive Engineer Divisional Accountant Executive Engineer
PIU Zone-7 Surat PIU Zone-7 Surat PIU Zone-7 Surat
SB Semo modular OT Page
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Condition for cement.pdf
GR RnB Revise.pdf
GR-TMT-Lap Length.pdf
INSTRUCTIONS TO PERSON TENDERING.jpg
JPG
Performance Bond and SD-Paripatra-2023.pdf
PIU SPECIAL CONDITIONS.pdf
Inclusion of Insurance clause as per new SBD.pdf
6372 Make List HO 15.10.2025.pdf
PQ OT.pdf
Specification.pdf
Schedule B.pdf
SBD.pdf
Tender Document.pdf
Revised PQ.pdf
Revised Tender Document.pdf
Corrigendum For revised Point No.6.pdf
Pre-bid Meeting Clerification.pdf
Re revised PQ.pdf
Revised Specification.pdf
lay out O.T.Mandvi.pdf
proposed Layout O.T.Bardoli (1).pdf
Corrigendum for Certification.pdf
Corrigendum for submission of Certification.pdf
Download all tender documents and submit your bid