| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹42.3 L+₹79,828.78 (1.92%)Rejected-AOC 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L2 | Rejected-AOC GREATER THAN L1 | |
| 3 | L3₹42.6 L+₹1.1 L (2.73%)Rejected-Finance | L3 | Rejected-Finance GREATER THAN L1 AND STANDS L3 | |
| 4 | L4₹42.9 L+₹1.4 L (3.44%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L4 | Rejected-Finance GREATER THAN L1 AND STANDS L4 |
Tender Value
₹43.2 L
EMD Value
₹86,323
Closing Date
2 Sept 2020, 2:00 pmClosed
Executive Engineer, NMD, PHE DTE.
Office of the Executive Engineer, Northern Mechanical Division Public Health Engineering Directorate Sukanta Sarani, Paresh Nagar, Savoke Road, Siliguri - 734001, District- Jalpaiguri
Renovation of 6.6KV Motor Starter feeder and other allied works at Different Pumping Stations under Darjeeling Pumping Water Supply Scheme with source Balason.
2020_PHED_292863_1
WBPHED/EE/NMD/NIeT- 10 OF 2020-2021
Open Tender
ELECTRICAL WORKS M/R
Item Rate
60 days
Balason, DARJEELING WATER SUPPLY SCHEME
Please refer Tender documents.
4 documents required · 4 mandatory
₹86,323
Yes
1 Oct 2020
13 Aug 2020
4 Sept 2020
17 Aug 2020
2 Sept 2020
17 Aug 2020
Amount
Intake Pumping Station
Supply, delivery and storage at site the following spares for damaged motor starter panel no 2 : -
Supply of movable horizontally isolation type rack in trolley consists of 400 A, 7.2 KV Vacuum contactor coupled with short operating shaft and electromagnetic actuation assembly with 250 A HV HRC fuse for back up protection of existing 1260 KW Induction motor with Potential Transformer of rating 6600/√3/ 110/√3/ 110/3 V of Class 0.5 and burden 50 VA/PH as per IS-3166/1992 along with incoming and outgoing male-female assembly, bushing and post insulator having equivalent dimension of existing Siemens make VCU panel of Model No. 3TL8100-3BF55 . Vacuum contactor should be of robust design having 1 million mechanical service life and have lower chopping current preferably below 0.6A for restricting overvoltage during pole separation and suitable for higher switching frequencies of 1200 cycles/hour which will be identical to the existing trolley & 100% Interchangeable in existing Siemens panel of type 8BK80 Old, 600 mm Width. Make : Siemens/ABB/CGL/L&T/AREVA
Flush mounted, non-draw out type, Single pole high speed master trip relay equivalent to existing VAJH13 of make Areva operated through 110V DC and having 3NO+1NC auxiliary contacts with flag. Make : Siemens/Areva/GE/ABB
Flush mounted, non-draw out type, trip circuit supervision relay to existing VAX 31 of make Areva operated through 110V DC and having 1NO+1NC auxiliary contacts with reverse HR flag. Make : Siemens/Areva/GE/ABB
Flush mounted, non-draw out type, three pole voltage operated auxiliary relay equivalent to existing VAA11 of make Areva operated through 110V DC and having contact combination per pole 2NOSR with flag. Make : Siemens/Areva/GE/ABB
Supply of Motor protection relay of equivalent dimension and features of damaged Siemens make motor protection relay of model no 7SK8041-5EB20-1HE0 having Enclosure 1/6 19”, 4 x I, 3 x V, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs : Iph = 1 A / 5A Rated auxiliary power : 60 V/ 110 V / 125 V/ 220 V DC, 115 V/ 230 V AC Installation enclosure flush mounting housing, screw type terminals, Region world, IEC/ANSI English (Language can be changed) front membrane system interface port B (device underside, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS 485 Without system interface, Port A Measurement: fault recording Functionality : XMZ Overcurrent time sw. XMZ PH(50/51) I>,I>>, I>>>, Op Ground fault protection XMZ GROUND (50N/51N) le>,le>>, le>>>, lep Ground fault/Ground short circuit prot, lee>, leep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function : Ground fault direction detection (*). Make : Siemens/Areva/ABB/GE
Intermediate Pumping Station :-
Supply, delivery and storage at site the following spares for damaged motor starter panel no 2 : -
Supply of Motor protection relay of equivalent dimension and features of damaged Siemens make motor protection relay of model no 7SK8041-5EB20-1HE0 having Enclosure 1/6 19”, 4 x I, 3 x V, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs : Iph = 1 A / 5A Rated auxiliary power : 60 V/ 110 V / 125 V/ 220 V DC, 115 V/ 230 V AC Installation enclosure flush mounting housing, screw type terminals, Region world, IEC/ANSI English (Language can be changed) front membrane system interface port B (device underside, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS 485 Without system interface, Port A Measurement: fault recording Functionality : XMZ Overcurrent time sw. XMZ PH(50/51) I>,I>>, I>>>, Op Ground fault protection XMZ GROUND (50N/51N) le>,le>>, le>>>, lep Ground fault/Ground short circuit prot, lee>, leep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function : Ground fault direction detection (*). Make : Siemens/Areva/ABB/GE
Sindhap Water Treatment Plant :-
Supply, installation of Power Bank of 240V AC input and 110V DC output required for constant DC voltage supply at spring charge motor in 11KV VCB at a suitable position in the sub-station room including control & modification of the same as per requirement by supplying necessary control wires, spares etc. as per direction of EIC. (With digital 110V for continuous monitoring).
Fitting fixing of the above new supply materials at respective pumping stations on existing position part by part by expert engineer and also commissioning by depute service engineer of parent company to complete the job as per direction of EIC.
Add GST @12% (CGST @6% and SGST @6%)
AAdd Labour welfare Cess @1%
B T PROJECTS PRIVATE LIMITED
STEEL ART INDUSTRIES PVT LTD
WEST BENGAL ENGINEERING CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .