| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PANCHAYATI RAJ ROHTAK | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
24 Jun 2020, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur-342011
REPAIRS TO ROOF TREATMENT IN ZONE-B AND ZONE-C AT DEFENCE LAB JODHPUR
2020_MES_348825_1
8383/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DETAILS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹16,000
Yes
5 Aug 2020
1 Jun 2020
26 Jun 2020
1 Jun 2020
24 Jun 2020
10 Jun 2020
2 Jun 2020 - 9 Jun 2020
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance not exceeding 100 metre complete all as specified & directed by Engineer-in-charge.(Brick koba,PCC padding of roof including water proofing treatment)
M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate with liquid water proofing compound as per manufacturer instructions, in roof padding for making good depressions / undulation in roof and maintain slope of roof complete all as specified & directed by Engineer-in-charge.
Preparing the surface of roof slab by brushing with wire brushes for removing loose/dirt materials etc with brooms or compressed air complete all as specified & directed by Engineer-in-charge.
Brushing neat cement slurry with 3.0 Kg of cement per sq.metre complete all as specified & directed by Engineer-in-charge.
M&L 10 mm thick plaster in cement mortar (1:4) with liquid water proofing compound on concrete surfaces of roof while concrete is grean and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L APP modified polymeric membrane minimum weight 3kg/sqm and minimum 3 mm thick centre core of 100 micron HMHDPE, outer film 20 micron each over and including one coat of bitumen primer conforming to [email protected]/sqm by torch application method complete all as specified & directed by Engineer-in-charge. Note:- Manufacturer and Application of membranes shall be by the applicator of the specialized firm ie M/S Texsa India Ltd, M/S Takki Asphalt Ltd, M/S IWL India Liimited, M/S M K Products India Pvt Ltd,M/S Bebgal Bitumen, M/S Shalimar tar products Ltd or any approved make.
M&L 300x300x10 mm thick cool roof SRI tiles by using spacers 6 mm thick and grey cement based tile adhesive and grouted with epoxy grout over and including 15 mm thick screed bed in CM 1:4 with liquid water proofing compound on APP membrane complete all as specified & directed by Engineer-in-charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate with liquid water proofing compound as per manufacturer instructions, in PCC platform for water tank complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete reinforced in roofs, floors (other than ground floors) beams, staircases, landing, chajjas and similar suspended work and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in slab and shelves/staging of tank supported on walls etc complete all as specified and directed by Engineer-in-charge.
M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
M & L mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips (for stirupps)complete all as specified and directed by Engineer-in-charge.
M & L use and waste of formwork to soffits of RCC Shelves and similar works not exc. 200 mm thick horizontal or slopping in rough finished flat surface of concrete complete all as specified and directed by Engineer-in-charge.
M & L use and waste of formwork to edges of RCC Shelves or similar work thickness exc. 05 cm and not exc. 10 cm in rough finished surfaces of concrete complete all as specified and directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick , plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M & L for preparing newly plastered/unplastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer on plastered surfaces,complete all as specified and directed by Engineer-in-charge.
M&L preparation of old plastered or unplastered surfaces of external wall including brooming down with steel wire brushing and applying two coat of cement base paint on external wallcomplete all as specified and directed by Engineer-in-charge.
Raking out joints/pointing to squared rubble masonry, coursed or uncoursed Jodhpur type complete all as specified and complete all as specified and directed by Engineer-in-charge.
M&L keyed pointing with white cement to squared rubble walling regular coursed Jodhpur type in CM (1:3)complete all as specified and directed by Engineer-in-charge.
Disconnecting existing water tank capacity Exc 250 and n exc 500 litres and removal from existing platform to facilitate execution of roof treatment setting aside and re-fixing in same position after completion of roof treatment work complete and reconnecting with existing GI pipe lines etc, complete all as specified and directed by Engineer-in-charge.
Disconnecting existing water tank capacity Exc 500 and n exc 1000 litres setting aside and re-fixing in same position after completion of roof treatment work complete and reconnecting with existing GI pipe lines etc, complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down old un-serviceable 500 ltrs capacity water tank, S&F 500 ltrs capacity rotational moulded polythene water storage tanks white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down old un-serviceable 1000 ltrs capacity water tank, S&F 1000 ltrs capacity rotational moulded polythene water storage tanks white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and directed by Engineer-in-charge.
S&F inrepairs PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and directed by Engineer-in-charge.
Taking up or down 15 mm bore steel tubing (with fittings) and connections including cleaning for refixing or removal to store complete all as directed by Engineer-in-charge.
Taking up or down 20 mm bore steel tubing (with fittings) and connections including cleaning for refixing or removal to store complete all as directed by Engineer-in-charge.
S&F GI tubing (ISI marked) 15 mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F GI tubing (ISI marked) 20 mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F GI tubing (ISI marked) 50 mm bore medium grade with all fittings and fixed complete in parapet walls as spout pipe or similar work complete all as specified and directed by Engineer-in-charge.
S&F in repairs, gun metal globe or gate valve, with iron wheel head, screwed both ends for 15 mm bore iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repairs, gun metal globe or gate valve, with iron wheel head, screwed both ends for 20 mm bore iron pipe complete all as specified & directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads,shoes, bends, swan-necks,etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls with clamps complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore (SWR) PVC bends any radius including jointing with solvent cement and finished/filling with PCC 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate ) complete as specified and directed by Engineer-in-Charge.
m/s Firoz khan
HOODA CONSTRUCTION COMPANY
SNEH CORPORATION
vinayandsons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .