Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.5 L+₹83,305 (7.13%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹12.9 L+₹1.2 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹13.0 L+₹1.3 L (11.2%)Rejected-Finance 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹13.4 L+₹1.7 L (14.5%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE (Army) Central Jodhpur
GE (Army) Central Multan Line Army Area Jodhpur
RE WIRING REPAIR REPLACEMENT OF EM FITTING AND FIXTURE IN CERTAIN OTM ACCN UNDER AREA OF AGE BR II OF GE ARMY CENTRAL ARMY AREA JODHPUR (9117/E8)
2022_MES_530393_1
GE/J/A- OF 2022-23 (9117/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (Army) Central Jodhpur
₹40,000
17 Aug 2022
11 Jun 2022
22 Jul 2022
11 Jun 2022
19 Jul 2022
25 Jun 2022
Amount
Note :- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ . (ii) Makes of material will be approved by GE in writing before commencement of work.
Taking down carefully copper/aluminium point wiring surface/ concealed (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell etc. removing materials from site of work complete or removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc., complete all as directed.
M&L for point wiring complete with using 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) passing in and including PVC conduit fixed on PVC saddle and clamp (ISI Marked) with accessories fixed on surface of wall/ roof/ ceiling etc., in sunken pressed steel terminal boxes in wall, including 3.00mm thick plastic laminated hylem sheet and 1.50 sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed :- (a) One light point controlled by one, one way switch
(b) One fan point controlled by one way switch, complete all as specified and as directed.
(c) One socket outlet 3 pin 5/6 Amps on same board, complete all as specified and as directed.
(d) One socket outlet 3 pin 5/6 Amp on independent board, complete all as specified and as directed.
(e) One two way point controlled by two, two way switch, complete all as specified and as directed.
All as per item No. 3.00 above but with using 2.5 Sqmm single core multistanded copper conductor cable and 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board, complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade ( (ISI Marked)) passing in PVC cassing-N-capping 25/32 mm dia fixed on surface of wall/roof/ceiling with existing/new sunken pressed steel terminal boxes including 3.00 mm thick plastic laminated sheet top cover and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed :- (a) One light point controlled by one, one way switch
(b) One fan point controlled by one way switch, complete all as specified and as directed.
(c) One socket outlet 3 pin 5/6 Amps on same board, complete all as specified and as directed.
(d) One socket outlet 3 pin 5/6 Amp on independent board, complete all as specified and as directed.
(e) One light point controlled by two, two way switch, complete all as specified and as directed.
All as per item No. 9.00 above but with using 2.5 Sqmm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board, complete all as specified and as directed.
M&L for concealed Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) , class V in concealed PVC conduit (ISI Marked) not less than 20 mm dia heavy duty with accessories etc and including sunken pressed steel terminal boxes in wall, including 1.50 Sqmm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed. Note :- Rates of chasing/cutting & making goods shall be included in the unit rate :- (a) One light point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one, one way switch through Regulator, complete all as specified and as directed.
(c) One three pin 5/6 Amp socket on same board with other switches, complete all as specified and as directed.
(d) One three pin 5/6 Amp socket on independent board, complete all as specified and as directed.
(e) One light point controlled by two, two way switch, complete all as specified and as directed.
All as per item No. 15.00 above but with 2.5 Sqmm (nominal area) cable for one 3 Pin 16 amp socket on independent board including one 2.5 sqmm copper conductor multi stranded green colour PVC insulated unsheathed cable 1100 volts grade as earth wire upto common earth & connected to earth dolly, complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type single pole one way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F switch piano flush type single pole one way 16 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F Socket outlet 2 in 1, 5 pin, 6 Amp flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F Socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F Switch piano flush type single pole two way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
M&L for Ceiling rose, 3 terminal/ PVC/ Polycarbonate, isolated body, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
M&L for Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
S&F Socket type (2 Module) electonic fan regulator flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ Havells/ Crabtree
Taking down and refixing of ceiling fan after servicing (Cleaning, oiling and greasing) and connecting up including provision of cable from ceiling rose or connector to fan, complete all as directed.
Taking down and refixing only exhaust fan after servicing (Cleaning, oiling and greasing) and connecting up including provision of cable from ceiling rose/connector to fan, complete all as directed.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider.
S&F Prewired distribution board (sheet metal enclosures) 240 volt with suitable rated bus bar for double door IP-43 DB's of apporved gauge suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way, complete all as specified and as directed by Engr-in-charge. Make : Legrand/ Schneider/ ABB
S&F Prewired distribution board (sheet metal enclosures) 415 volt TPN 4 way double door IP-43 DB's suitable for one TPN/ isolator 4 pole MCB as incoming and three TPN MCB as outgoing, complete all as specified and as directed by Engr-in-charge. Make : Legrand/ Schneider/ ABB
S&F MCB Single pole "C" series 5-32 Amps (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F MCB Single pole & neutral "C" series 40 Amps (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F MCB Single pole & neutral "C" series 63. Amps (ISI Marked), complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F repair electronic driver as per sample for LED fitting up to 15watt), complete all as specified and as directed. Make : Crompton/ Havells/ CG/ Philips/ Osram.
S&F repair electronic driver as per sample for LED fitting up to 36watt), complete all as specified and as directed. Make : Crompton/ Havells/ CG/ Philips/ Osram.
Taking down and refixing sheet metal enclosure 240/415 volts with suitable rated bus bar for double door IP-43 DB's SPN 8/4 way/ TPN of any make and connceled in wall or fix on surface with nuts and accessories), complete all as directed by Engr-in-charge.
S&F MCB TPN "C" Curve 63 Amps 16 KA, complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F MCB TPN "C" Curve 100 Amps 16 KA, complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F MCB TPN "C" Curve 125 Amps 16 KA, complete all as specified and as directed. Make : Legrand/ Schneider/ ABB
S&F LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose), complete all as specified and as directed by Engr-in-Charge. Make : Philips/ Bajaj/ CG.
Taking down and re-fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose), complete all as directed by Engr-in-Charge.
S&F LED light fitting 1 x 9W /1 X 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size), complete all as specified and as directed. Make : Philips/ Bajaj/ Crompton
S&F LED decorative wall light Grace 9W Wall Light, White all accessories pre wired and including connecting up to fiting with flexible cable of suitable size), complete all as specified and as directed. Make : Crompton/ Phillips/ Bajaj
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completeconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by Engr-in-Charge. Make : Crompton/ Phillips/ Bajaj
S&F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc., Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size), complete all as specified and as directed. Make : Crompton/ Phillips/ Bajaj
S&F LED light fitting, mirror type, with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size), complete all as specified and as directed. Make : Crompton/ Phillips/ Bajaj
S&F round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size), complete all as specified and as directed. Make : Crompton/ Phillips/ Bajaj
S&F in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed by Engr-in-Charge.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth), complete all as specified and as directed by Engr-in-Charge.
S&F RCBOs for earth leakage, overload and short circuit protection Double pole, 100MA, 40 Amp ), complete all as specified and as directed by Engr-in-Charge.
S&F RCBOs for earth leakage, overload and short circuit protection Double pole, 100MA, 63 Amp), complete all as specified and as directed by Engr-in-Charge.
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and as directed.
S&F Air termination, single pointed, copper rod 12mm dia and 300mm long), complete all as specified and as directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw), complete all as specified and as directed.
S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc., for roof conductors and down conductors above ground, complete all as specified and as directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm and 50mm deep, complete all as specified and as directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc., with 3 mm thick plastic laminated sheet cover of size 175mm x 100mm and 50mm deep, complete all as specified and as directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 x 150 and 50 mm deep), complete all as specified and as directed.
M&L in repairs sub main wiring with PVC insulated and unsheathed 4 Sqmm single core multistrandred copper conductor cable (FRLSH) passing through in and including PVC conduit fixed on surface (ISI Marked) and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, including 4 Sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire), complete all as specified and as directed. Note :- Two runs of cable 4 Sqmm and One run of 4 Sqmm along with conduit shall be measured as one unit length.
M&L in repairs sub main wiring with PVC insulated and unsheathed 4 Sqmm single core multistrandred copper conductor cable (FRLSH) passing through in and including PVC conduit , concealing in walls ( by means of chasing including making good existing surface and matching existing surface) (ISI Marked) and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, including 4 Sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- Two runs of cable 4 Sqmm and One run of 4 Sqmm along with conduit shall be measured as one unit length.
M&L in repairs sub main wiring with PVC insulated and unsheathed 6 Sq mm single core multistrandred copper conductor cable (FRLSH) passing through in and including PVC conduit fixed on surface (ISI Marked) and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire), complete all as specified and as directed. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm along with conduit shall be measured as one unit length.
M&L in repairs sub main wiring with PVC insulated and unsheathed 6 Sqmm single core multistrandred copper conductor cable (FRLSH) passing through in and including PVC conduitconcealing in walls ( by means of chasing including making good existing surface and matching existing surface) (ISI Marked) and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, including 6 Sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm along with conduit shall be measured as one unit length.
M&L in repairs sub main wiring with PVC insulated and unsheathed 10 Sqmm single core multistrandred copper conductor cable (FRLSH) passing through in and including PVC conduit fixed on surface (ISI Marked) and conduit accessaries fixed on surface of wall, ceiling etc., making good the distrurbed surface, including 10 Sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire), complete all as specified and as directed. Note :- four runs of cable 10 Sqmm and One run of 10 Sqmm along with conduit shall be measured as one unit length.
Repair, Servicing/ rewinding of submersible/ pressure pump any type of capacity upto 5 HP, single or three phase, any make incl connection, testing), complete all as specified and as directed.
Taking down old steel/ PVC conduit pipe in sub main wiring and Supply and fixing in repair PVC conduit 20/25mm (ISI Marked) (MMS) grade with clamps and accessories), complete all as directed. Make : Polycab/ Plaza/ Kalinga
S&F repair PVC insulated and unsheathed FRLSH single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/ burnt circuit), complete all as specified and as directed.
S&F repair PVC insulated and unsheathed FRLSH single core multistranded copper conductor for repair, in existing conduit of size 2.5 sqmm as in replacement of any defective/ burnt circuit), complete all as specified and as directed.
S&F repair PVC insulated and unsheathed FRLSH single core multistranded copper conductor for repair, in existing conduit of size 4.0 sqmm as in replacement of any defective/ burnt circuit), complete all as specified and as directed.
S&F Street light bracket made out of medium grade GI Pipe 32mm dia, 1.5mtr long (as per sample for suitable for bldg security light fitting) bent to shape including GI Clamps nut, bolts washers, reducer of required size for suitable any type fittings etc., (complete including necessary painting), complete all as specified and as directed by Engr-in Charge.
Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion), complete all as specified and as directed. Note :- Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete
Note :- (i) Contract Sum shall be arrived at after deduction of amount of Schudule of Credit.
LOKESH ELECTRICAL WORKS CONTRACTOR
Narendra General Suppliers
M/s. Dhananjay Construction
Nvimal Engineers and Contractor
VARDHMAN SALES CORPORATION
CHAHAR ENGINEERS AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .