Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.5 L+₹79,655 (4.05%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.1 L+₹3.4 L (17.3%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹23.4 L+₹3.8 L (19.2%)Rejected-Finance 12 DORU DOORU VERINAG ROAD NEAR TOWN HALL ANANTHNAG JAMMU KASHMIR 192211 | ANANTNAG | JAMMU AND KASHMIR | 192211 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
10 Apr 2025, 6:00 pmClosed
Garrison Engineer Kargil
Office of GE Kargil, PIN - 908121, C/o 56 APO
TOKEN NO. GE/K-90/2024-25 - REPAIR AND MAINT OF EXTERNAL WATER SUPPLY SYSTEM AT KARGIL MIL STN UNDER GE KARGIL
2025_MES_700510_1
TOKEN NO. GE/K-90/2024-25
Open Tender
Civil Works - Water Works
Item Rate
180 days
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kargil
₹54,000
Office of GE Kargil
13 Jun 2025
6 Mar 2025
14 Apr 2025
6 Mar 2025
10 Apr 2025
22 Mar 2025
13 Mar 2025
Amount
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus, deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall including ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 1 lakh litres capacity complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall, ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 25000 litres capacity complete all as specified and directed by EIC.
M&L for Cleaning of iron reservoir tank to be cleaned after removing/draining out silt and scrapping the internal surfaces of the tank with wire brush, removal of all the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the tank complete with bleaching powder solution including painting internal surface with epoxy paint complete all as specified and providing two coats of synthetic enamel paint on external surface of tank and writing “TANK CLEANED ON ………..” on external surface with white paint on black base. The letter height should not be less than 4" complete all as specified and directed by EIC for tanks of capacity 25000 Ltr.
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall, ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 50000 litres capacity complete all as specified and directed by EIC.
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall including ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 16500 litres capacity complete all as specified and directed by EIC.
M&L for Cleaning of RCC Semi underground reservoir / tank to be cleaned from silt and scrapping the internal surfaces of the tank with wire brush, removing the fungus deposited on the internal surface and removing the scrap material not exceeding 100 mtr away from site and washing the reservoir/UG sump with bleaching powder solution including applying two coats of lime wash on internal surface of wall including ceiling, floor complete and writing “TANK CLEANED ON ………..” on external surface with white paint on black base including preparation of surface & applying two coats of cement based paint on the external surface. The letter height should not be less than 4" for 34500 litres capacity complete all as specified and directed by EIC.
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in hard/ dense soil complete all as specified.
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, all as directed.
Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, all as directed.
Taking up or down old unserviceable GI/MS/PPR tubing and connetions of following sizes including all fittings from the trenches, wall, floor etc complete as directed.
15 mm bore size
20 mm bore size
25 mm bore size / 32 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
100 mm bore size
150 mm bore size
Relaying/refixing after repairing/Cleaning thoroughly complete to the GI/MS pipes in old or new position obtained from above item No. 10 including new fittings complete of following sizes in trenches :-
15 mm bore size
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
100 mm bore size
Material and labour for laying of GI tubing medium grade of ISI marked complete with all necessary fittings of the follwing sizes in trenches/floors/wall
15 mm bore size
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
Material and labour for laying of GI tubing medium grade of ISI marked of size 150 mm complete with flanged joints and other fittings in trenches/floors/wall complete all as directed .
S & F in repair cast iron sluice valve, class PN 1.6, conforming to IS-14846, ISI marked with brass spindle complete with flanged ends including necessary nuts, bolts, washers and rubber gaskets, 3mm thick, heavy duty and iron wheel complete with jointing material including taking out old unserviceable sluice valve of following sizes :-
S & F Ball valve 15 mm bore with polythene float and flynut complete, screwed for iron pipes and fixed complete including taking down of old one.
S & F Ball valve 20 mm bore with polythene float and flynut complete, screwed for iron pipes and fixed complete including taking down of old one.
S & F Ball valve 25 mm bore with polythene float and flynut complete, screwed for iron pipes and fixed complete including taking down of old one.
S&F Gun metal gate valve 40 mm bore with iron hand wheel head , screwed both ends for iron pipes and fixed complete including taking down of old one.
S&F Gun metal gate valve 50 mm bore with iron hand wheel head , screwed both ends for iron pipes and fixed complete including taking down of old one.
Material and labour for PCC (1:2:4) type B2 using 20mm graded crushed stone aggregate as in foundation, filling and mass concrete including necessary form work, including cutting of roads complete all as directed.
Supply & laying 3-layer PP-R Polypropylene random copolymer pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc including all necessary fittings such as T, Bend, Joints, Nipple etc of following sizes complete all as specified and directed.
20 mm bore size (outer dia of pipe in mm)
25 mm bore size (outer dia of pipe in mm)
32 mm bore size (outer dia of pipe in mm)
S&F in repair foot valve /strainer of size 80mm bore for suction pipe flanged ISI marked complete with nuts, bolts and washers packing material etc. complete all as specified & directed.
Taking out submersible pump of any capacity from bore well and lowering into bore well after repairing/rectification of defects in submersible motor pump (Note-Repairing of pump and motor will be measured and paid separately).
Repair to submersible motor assembly of capacity 25 HP by dismantling unserviceable motor by cutting, wornt out copper winding as per specification,coupling etc and replacing with new copper winding and necessary parts with necessary connections and testing then Reassembling with the pump and motor including scrubbing and painting to motor complete as directed as specified by Engr-in-Charge.
Repair to submersible pump of capacity 25 HP by dismantling unserviceable pump by replacing, wornt out impeller sets and replacing with new impeller sets, motor pump coupling etc complete as directed as specifed by Engr-in-Charge.
Repair and maintenance of centrifugal electric driven self priming pump set of capacity 40 HP by disconnecting the electric connection,removing from site and dismantling it and replacing the worn out motor shaft,bearing, worn out winding and replacing with as per existing specification, repair to centrifugal pump by replacing the worn out impeller, shaft, gland, nuts and bolts and refixing at same position all as specified and as directed by Engr-in-Charge.
S&F in repair of Three Phase automatic star delta starter suitable for centrifugal pump/ submersibile pump set of capacity 12.5 HP, over load relay and shortcircuit protection complete all as specified and directed by the Engr In charge.
S&F in repair of MS column pipe up to 50mm dia heavy duty medium grade' with MS flanged and drilled at both ends duly threaded and welded of 3 mtr long alongwith cut for passing the submersible cable including bolts, nuts, washers and rubber insertions packing complete all as specified and directed by Engineer-in-Charge.
S&F in repair of PVC insulated and sheathed submersible cable flat three core copper conductor cable size 10.00 sqmm 1100 volts grade conforming to IS-694/1990.
S&F in repair of PVC insulated and sheathed submersible cable flat three core copper conductor cable size 6.00 sqmm 1100 volts grade conforming to IS-694/1990.
S & F in repair of unserviceable lead acid maintenance free battery 12 Volts 180 AH battery complete all as specified and as directed by Engr-in-Charge.
S & F in repair of Battery Terminal for 12 Volts 180 AH battery complete all as specified and as directed by Engr-in-Charge
S & F in repair of Battery Cable of size 16Sqmm Single Core made of stranded copper conductor for 12 Volts 180 AH battery complete all as specified and as directed by Engr-in-Charge
M&L for repair of leakage of water supply line including necessary excavation up to 1.5 m depth in hard /dense soil with returning filling and removal of excavated soil and testing of pipeline after reparing complete all as specified and directed by engr-in charge. Note - Any connected items required for repair of pipe line such as Bend, socket, Aluminium sheet, insulation and anti freezing cable etc are included in quoted rate).
M&L for 40mm thick closed cell elastomeric insulation min 42 Kg/m3 density glass wool fiber insulation with aluminium sheet cover over any size of GI/PPR pipes on exposed portion including taking out of old insulation complete all as specified and directed by Engr-in-Charge.
M&L for providing tracer/ antifreezing cable (self regulating heating cable) 220Volt, min 25 watt/M required to keep the pipe warm avoiding freezing water all as specified including electrical wiring cable for connection of suitable size including taking down of burnt tracer cable Complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair of booster pump set of cap 0.5 HP, 230 volts, 1 phase, 50 Hz complete all as specified and directed by Engr-in-Charge. Make -Crompton (model No- MINI-FORCE II) or Equivalent
Construction of valve pit chamber of size 90cmx90cmx90cm (Internal dimension) of double brick masonary with internal plastering from the top of surface including cover of MS sheet 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coat of synthetic enameled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement mortar 1:3, foundation concrete 1:3:6 including necessary earthwork including demolition of old valve pit chamber complete all as specified and directed.
Repair to non clogging centrifugal electric driven self priming pump set of capacity 7.5 HP by disconnecting the electric connection, removing from site and dismantling it and replacing burnt out winding with same guage of winding wire and repair to pump by replacing the worn out shaft,gland nut bolts, impleller etc. and refixing at the same position complete all as directed.
Note : Deduction for amount of Rs. 75,295.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract.
KASHMIR FAIR DEAL SERVICES (BID ID -3272976)
M/S TRADE LINK (BID ID -3276858)
M/S ALI MOHD AND SONS (BID ID -3277227)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .