| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78,681Accepted-AOC | L1 | Accepted-AOC L1 accepted |
| Sl No | Description | Qty | Unit | SANTHOSH KUMAR KAMALADHARAN L1 |
|---|---|---|---|---|
| 1.00PUMPSET | ||||
| 1.00 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | 25 | metre | 132.43 ₹3,310.75 Lowest |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 5 | metre | 237.28 ₹1,186.4 Lowest |
| 1.00 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 15 | metre | 88.93 ₹1,333.95 Lowest |
| 1.00 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 2 | each | 236.2 ₹472.4 Lowest |
| 1.00 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | 1 | each | 2,282.23 ₹2,282.23 Lowest |
| 1.01 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door | 1 | each | 2,084.29 ₹2,084.29 Lowest |
| 1.01 | 2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole | 1 | each | 658.23 ₹658.23 Lowest |
| 1.01 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 1 | each | 1,004.69 ₹1,004.69 Lowest |
| 1.01 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 3 | metre | 107.07 ₹321.21 Lowest |
Tender Value
₹79,477
EMD Value
₹1,987
Closing Date
21 Mar 2024, 10:00 amClosed
Assistant Engineer lid ew section office poothadi
Assistant Engineer lid ew section office poothadi
2023-24 Annual Plan Poothadi Grama Panchayath Pro.288/24 Cheeyambam Paniya colony Drinking Water Project Renovation Electrical Work
2024_LSGD_669499_11
AE/PDY/TR/07/2023
Open Tender
Electrical Works
Item Rate
Kenichira
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹1,987
Yes
7 Nov 2025
14 Mar 2024
22 Mar 2024
14 Mar 2024
21 Mar 2024
14 Mar 2024
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1041968.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .