| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21,095Accepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹22,110+₹1,015.32 (4.81%)Rejected-AOC | L2 | Rejected-AOC higher bidder |
| Sl No | Description | Qty | Unit | BALAKRISHNAN K L2 | UDAYAKUMAR M M L1 |
|---|---|---|---|---|---|
| 1.00Parking shed | |||||
| 1.00 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | 12.5 | sqm | 860 ₹10,750 | 842.1 ₹10,526.25 Lowest |
| 1.00 | 10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes | 43.75 | kg | 190 ₹8,312.5 | 176.6 ₹7,726.25 Lowest |
| 1.00 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.01 | cum | 9,500 ₹47.5 | 9,235.9 ₹46.18 Lowest |
| 1.00 | OD452724/2025-2026:. Providing and fixing on wall face square type ( or nearest available) section UPVC rain water gutter pipes of 150mm ( 6 inches) or nearest, 4kg/cm2 pressure rating ,conforming to IS 13592: Type A , including jointing ( including cutting, chamfering ,joint lubrication if necessary) securely fixed using galvanized iron brackets and clamps at maximum 1 M intervals , leak testing and making good the surface , complete in all respects as per manufacturers specifications and direction of the engineer in charge (Modified DAR 12.41.2) | 5 | metre | 600 ₹3,000 | 559.2 ₹2,796 Lowest |
Tender Value
₹21,097
Closing Date
21 Feb 2026, 5:00 pmClosed
Assistant Engineer, LSGD(EW) Section, Sreekrishnap
O/o Assistant Engineer LSGD(EW) Section Sreekrishnapuram
SKPM GP Construction of a shed for the family health center palliative vehicle
2026_LSGD_836002_1
TR/6297/2026_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
Sreekrishnapuram
Please refer Tender documents.
9 documents required · 9 mandatory
₹335
Yes
Yes
8 Apr 2026
13 Feb 2026
24 Feb 2026
13 Feb 2026
21 Feb 2026
13 Feb 2026
Parking shed
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
OD452724/2025-2026:. Providing and fixing on wall face square type ( or nearest available) section UPVC rain water gutter pipes of 150mm ( 6 inches) or nearest, 4kg/cm2 pressure rating ,conforming to IS 13592: Type A , including jointing ( including cutting, chamfering ,joint lubrication if necessary) securely fixed using galvanized iron brackets and clamps at maximum 1 M intervals , leak testing and making good the surface , complete in all respects as per manufacturers specifications and direction of the engineer in charge (Modified DAR 12.41.2)
stage.html
html • 0.04 MB
techsummary_1406832.pdf
finsummary_1406832.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1406832.xls
BOQ • 0.30 MB
BD.pdf
Tender Documents • 1.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .