| 1 | L1₹21,095Accepted-AOC | ₹21,095 Quoted ₹21,094.68 | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹22,110Rejected-AOC | ₹22,110 | L2 | Rejected-AOC higher bidder |
| Sl No | Description | Qty | Unit | BALAKRISHNAN K L2 | UDAYAKUMAR M M L1 |
|---|---|---|---|---|---|
| 1.00Parking shed | |||||
| 1.00 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | 12.5 | sqm | 860 ₹10,750 | 842.1 ₹10,526.25 |
| 1.00 | 10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes | 43.75 | kg | 190 ₹8,312.50 | 176.6 ₹7,726.25 |
| 1.00 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.01 | cum | 9,500 ₹47.50 | 9,235.9 ₹46.18 |
| 1.00 | OD452724/2025-2026:. Providing and fixing on wall face square type ( or nearest available) section UPVC rain water gutter pipes of 150mm ( 6 inches) or nearest, 4kg/cm2 pressure rating ,conforming to IS 13592: Type A , including jointing ( including cutting, chamfering ,joint lubrication if necessary) securely fixed using galvanized iron brackets and clamps at maximum 1 M intervals , leak testing and making good the surface , complete in all respects as per manufacturers specifications and direction of the engineer in charge (Modified DAR 12.41.2) | 5 | metre | 600 ₹3,000 | 559.2 ₹2,796 |
Tender Value
₹21,097
Closing Date
21 Feb 2026, 5:00 pmClosed
Assistant Engineer, LSGD(EW) Section, Sreekrishnap
O/o Assistant Engineer LSGD(EW) Section Sreekrishnapuram
SKPM GP Construction of a shed for the family health center palliative vehicle
2026_LSGD_836002_1
TR/6297/2026_5_1_1/1
Open Tender
Civil Works - Buildings
Sreekrishnapuram
Please refer Tender documents.
9 documents required · 9 mandatory
₹335
Yes
Yes
8 Apr 2026
13 Feb 2026
24 Feb 2026
13 Feb 2026
21 Feb 2026
13 Feb 2026
Parking shed
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
OD452724/2025-2026:. Providing and fixing on wall face square type ( or nearest available) section UPVC rain water gutter pipes of 150mm ( 6 inches) or nearest, 4kg/cm2 pressure rating ,conforming to IS 13592: Type A , including jointing ( including cutting, chamfering ,joint lubrication if necessary) securely fixed using galvanized iron brackets and clamps at maximum 1 M intervals , leak testing and making good the surface , complete in all respects as per manufacturers specifications and direction of the engineer in charge (Modified DAR 12.41.2)
stage.html
html • 0.04 MB
techsummary_1406832.pdf
finsummary_1406832.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1406832.xls
BOQ • 0.30 MB
BD.pdf
Tender Documents • 1.80 MB
Download all tender documents and submit your bid