| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹7.0 L+₹10,000 (1.45%)Rejected-AOC | L2 | Rejected-AOC A DEFFRENCE IN THE NAME GIVEN THE BOQ | |
| 3 | L3₹7.5 L+₹58,063.31 (8.43%)Rejected-AOC | L3 | Rejected-AOC THE AMOUNT QUOTED BY THIS COMPANY IS MORE THAN THE AMOUNT SET ASIDE FOR THE WORK | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT RECIEVED PHYSICAL COVER |
Tender Value
₹6.9 L
EMD Value
₹17,500
Closing Date
13 Jul 2020, 3:00 pmClosed
DR ABBAS N MEDICAL OFFICER
COMMUNITY HEALTH CENTER KATAMPAZHIPURAM, KATAMPAZHIPURAM PO, PALAKKAD- 678633
SITC OF 50 KVA / 40 KW DIESEL GENERATOR SET AT COMMUNITY HEALTH CENTER KATAMPAZHIPURAM
2020_DHS_369687_1
01/2020-21/CHC KTPM
Open Tender
Electrical Works
Item Rate
45 days
CHC KATAMPAZHIPURAM
PLEASE REFER TENDER DOCUMENT
5 documents required · 5 mandatory
₹1,500
Yes
online
₹17,500
Yes
19 Sept 2020
3 Jul 2020
17 Jul 2020
3 Jul 2020
13 Jul 2020
3 Jul 2020
Amount
Supply and installation of 50 KVA/40KW , Three phase Diesel Generating Set with CPCBII approved acoustic enclosure with AMF Panel and comprising of KOEL iGREEN/Leyland/ Escorts/ equivalent,Radiator Cooled Diesel engine 1500 RPM, complete with standard accessories including control wiring, Coupled to“Stamford/LS/equivalent ” Alternator rated at 50KVA/40 KW at 415 Volts mounted on Channel Iron Base Frame complete with Fuel Tank, Standard manual Control System and Batteries with battery charger.The DG set should have warranty of 2 years from the date of installation. od125356/2019_2020
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 14.1
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. 14.7
Providing 15mm thick cement plaster of mix 1:4 (1cement : 4 fine sand) at all levels. 14.12
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm. 90.12.5.28
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size. 90.12.10.3
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp. 90.12.7.28
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5X 35 sq. mm (32mm) (9.1.21)
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class) 90.16.2.4
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 6.00 mm copper conductor (4 SWG) 90.16.1.6
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 6. mm ( 4 SWG) 90.16.5.6
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 2.65 mm copper conductor (12 SWG) 90.16.5.2
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) 90.16.2.1
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2 metre long etc. with charcoal/ coke as required. od128094/2019_2020
Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strip of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. od125533/2019_2020
Supply and providing following size M. S. pipe - 5mm thickness complete with suitable size 12mm flange coupling with minimum 4/5mtr using allied packing with MS bolt with washer and rising the same on the wall/ parapet using chain pullies, scaffoldings, supports with M.S angles/channels etc. including painting the pipe with one coat of zinchromate primer over a coat of high temperature resistance alu. paint etc. for extending the exhaust pipe of the newly errected D. G. sets. 80mm dia or nearest size B class MS pipe. od125536/2019_2020
Copying charges for additional copies per A3 sheet. od125538 /2019_2020
Copying charges for additional copies per A3 sheet. od125539 /2019_2020
Supply,installation,testing and commissioning of Electric Hooter as required. 125540/2019_2020
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp switch. (1.24.1)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) (1.27.1)
Supplying and fixing PVC batten/angle holder including 3w LED bulb and plastic shade and giving connection etc.as required. Od131419/2019_2020
Supply and drawing 650/1100 V grade FRLS PVC insulated copper conductor,single core cables in the existing surface / recess conduit as required. 2x1.50 sq.mm. (1.17.2)
Supply and fixing the following sizes of light gauge PVC Conduit along with accessories on surface/recess including cutting the wall making good the samein case of recessed conduit as required. 20 mm. 90.6.10.1(od15219/2019_ 2020)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) 90.16.5.1
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface/recess conduit as required including giving necessary connections of the following sizes. 2 core 1.50 sq mm. 90.6.5.4
Do - 5 amps to 32 amps rating, 240/415 volts, "C" curve, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. (2.10.1 ) -2 each 29. Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. (od63845/2019_2020)
Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. (od63845/2019_2020)
Supply and providing 12mm thick 2x1m electrical grade chequied type rubber mat in front of panels & Generators
Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm,4cm or 5 cm height
Fees for getting sanction from Electrical inspectrate including all laison work etc.(actuals will be paid on production of relevant documents.) (od 20570/2019_2020)
ARUN.C.S
Generic Power Pvt Ltd
POWERLINE CONSULTANTS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_523162.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .