Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.0 LAccepted-AOC | ₹74.0 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹74.2 L+₹14,398.92 (0.19%)Rejected-AOC | ₹74.2 L+₹14,398.92 (0.19%) | L2 | Rejected-AOC HIGHER |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance RESIDENCE JAGDAMBA COLONY DIST PITHORAGARH | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-NOT SUBMITTED |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-NOT SUBMITTED |
Tender Value
₹74.2 L
EMD Value
₹1.5 L
Closing Date
12 Mar 2024, 12:00 pmClosed
EE RWD PITHORAGARH
EE RWD PITHORAGARH
Construction of class room and Laboratory 02 no at G I C Gurna Pithoragarh
2024_RES_70951_1
2969 dated 04.03.2024
Open Tender
Civil Works
Item Wise
365 days
PITHORAGARH
Please refer Tender documents.
1 document required · 1 mandatory
₹4,720
EE RWD PITHORAGARH (E-CHALLAN)
₹1.5 L
7 Aug 2024
5 Mar 2024
12 Mar 2024
5 Mar 2024
12 Mar 2024
5 Mar 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Providing and laying in position cement concrete of specified grade cost of centring and shuttering - -All work upto plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in 1:6 C/S Mortar.
Reinforced cement concrete work in excluding shuttering, finishing and reinforcement--- 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Substructure
Random rubble masonry with hard stone in foundation and plinth i levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
Reinforced cement concrete work in excluding shuttering, finishing and reinforcement--- 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Superstructure
Centring and shuttering including strutting,ropping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete.
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.. .
Structural steel work riveted, bolted or welded in built up se trusses and framed work, including cutting, hoisting, fixing in and applying a priming coat of approved steel primer all complete
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles,including applying a priming coat of approved steel primer.
Providing and fixing M.S. Tubular frames for doors, windows, ventilatorsand cupboard with rectangular/ L-Type sections, made of 1.60 mm thickM.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
S/F of glass paneswith putty & nails whereever necessary Float glass panes of thickness 5mm
Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Brick work with F.P.S. bricks of class designation 75 in superstruct level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix1:6 (1 cement: 6 fine sand)
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 grad finished with a floating coat of neat cement including cement slurry 40mm thick with 20mm nominal size stone aggregate.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying vitrified floor tiles ,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry including grouting the joints with white cement and matching pigments etc., completes Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
Marble stone flooring with 18 mm thick marble stone, as per sample ofmarble approved by Engineer-in-charge, over 20 mm (average) thick baseof cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble
Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters 30mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing aluminium handles ISI marked anodised(anod less than grade AC10 as perIS:1868)transparent or dyed to req. - 125 mm
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete.- 300x10mm
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete.- 300x16 mm
Providing and fixing aluminium hanging floor door stopper ISI mar (anodic coating not less than grade AC 10 as per IS : 1868) transp required colour and shade with necessary screws etc. complete.Twin rubber stopper
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete..
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer
Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives New work (Two or more coats applied @ 1.43 litre/10 sqm. Over and including priming coat of exteriorprimer applied @ 0.90 litre/10 sqm
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centring, shuttering and finishing. 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External Work- 15mm
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A,including jointing with seal ring conforming to IS:5382,leaving 10mm gap for thermal expansion (i) single socket
110 mm dia
Providing and fixing on wall face unplasticised -PVC moulded fittings /accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A,including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5°
110 mm bend
Excavation in soil in Hilly Area by mechanical means Without useinng Dozer including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
OM GROUPS CONSTRUCTION AND SUPPLIERES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_85182.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .