Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.2 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹38.0 L+₹5.2 L (15.7%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹39.7 L+₹6.9 L (21.0%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹41.7 L+₹8.9 L (27.0%)Rejected-AOC PLOT NO 26 1ST FLOOR PRATAP NAGAR NEAR JAIL ROAD NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L-4 | Rejected-AOC L-4 | |
| 5 | Rejected-Technical B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | - | Rejected-Technical No, 10 Nos CA Cancelled vide HQ CEWC letter No 37940 oblick WLR Oblic D to S oblick QE Jun 2025 oblick 36 oblick E8 dated 01 Sep 2025 |
| Sl No | Description | Qty | Unit | SNOWY ENGINEERING INC L2 | RUCHIKA ENGG.WORKS L1 | Shivam Firetech Engineers L4 | national engineering L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M & L for Servicing of VRF inverter split type 3 phase ac of capacity 14 TR. of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Any u/s items need to be replaced/gas charging etc shall be paid seperately under respective items. | 1 | Each | 7,500 ₹7,500 | 5,000 ₹5,000 Lowest | 5,772 ₹5,772 | 5,535 ₹5,535 |
| 2.00 | Isolating/Disconnecting and dismantling of UNSV compressor 14 TR capacity from VRF type AC unit and supply and fixing with new hermatically sealed scroll compressor of 8 HP cpacity including leak tesing and pressure testing for 24 hours and gas changing with R-22 refrigarent including testing with Nitrogen gas etc, complete all as specified and directed by Engr-in-Charge. | 1 | Each | 78,900 ₹78,900 | 30,000 ₹30,000 Lowest | 38,080 ₹38,080 | 36,520 ₹36,520 |
| 3.00 | Taking down the existing UNSV expansion valve supply and fixing new thermostatic expansion valve for 8 HPcapacity compressor complete all as specified and directed by the Engr-in-Charge. | 1 | Each | 2,200 ₹2,200 | 15,000 ₹15,000 | 85 ₹85 Lowest | 800 ₹800 |
| 4.00 | S&F in replacement vaccume filter of VRF 14 TR including taking out unserviceable complete all as specifed and directed. | 1 | Each | 4,130 ₹4,130 | 12,000 ₹12,000 | 1,615 ₹1,615 | 1,550 ₹1,550 Lowest |
| 5.00 | S&F in replacement contactor 40 A 3 phase sutable for VRF Unit 14 TR including taking out unserviceable complete all as specified and directed. | 1 | Each | 6,340 ₹6,340 | 14,250 ₹14,250 | 3,800 ₹3,800 | 3,650 ₹3,650 Lowest |
| 6.00 | M&L in replacement PCB for VRF unit 14 Ton capacity including taking out unserviceable PCB complete all as specified and directed . | 1 | Each | 74,850 ₹74,850 | 40,000 ₹40,000 Lowest | 51,050 ₹51,050 | 48,960 ₹48,960 |
| 7.00 | M&L in replacement Fan Motor of VFR unit 14 TR Capacity of approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and as directed. | 1 | Each | 15,000 ₹15,000 Lowest | 45,000 ₹45,000 | 17,850 ₹17,850 | 17,120 ₹17,120 |
| 8.00 | S&F in replacement compressor for VRF unit 14 TR capacity including bracing the sunction and discharge lines complete all specified and dircted. | 1 | Each | 89,300 ₹89,300 | 1,20,000 ₹1,20,000 | 69,735 ₹69,735 | 66,880 ₹66,880 Lowest |
| 9.00 | M&L in replacement Remote with ful kit of VRF unit 14 TR capacity (As per sample or as per site requirement) complete all as specified and as directed. | 1 | Each | 85,300 ₹85,300 | 30,000 ₹30,000 Lowest | 66,375 ₹66,375 | 63,660 ₹63,660 |
| 10.00 | M&L for MCB single pole 6-40 Amps C Curve 240 Volt complete all as specified and as directed. | 5 | Each | 185 ₹925 | 150 ₹750 Lowest | 220 ₹1,100 | 210 ₹1,050 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
21 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RnD Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
REPAIR MAINT OF SUMMER COOLING APPLIANCES SYSTEMS AND ALLIED WORKS IN ZONE B AT KWC AREA UNDER GE I RnD DELHI
2025_MES_732782_1
GE/RND/T-75/DLI/2025-26
Open Tender
Civil Works
Item Rate
240 days
Delhi
Class-D, Cat- c(i)
2 documents required · 2 mandatory
₹500
Yes
GE I RnD Delhi
₹82,000
31 Jan 2026
26 Sept 2025
23 Oct 2025
26 Sept 2025
21 Oct 2025
14 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TDR.pdf
Tender Documents • 1.50 MB
BOQ_820458.xls
BOQ • 1.05 MB
corrigendum01t.pdf
PDF • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .