| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹18.0 L+₹1.6 L (9.96%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance Being not L1 bidder | |
| 3 | L3₹19.3 L+₹3.0 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Being not L1 bidder | |
| 4 | L4₹20.0 L+₹3.6 L (22.1%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L4 | Rejected-Finance Being not L1 bidder | |
| 5 | L5₹21.5 L+₹5.2 L (31.8%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-Finance Being not L1 bidder |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
20 Mar 2023, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
CERTAIN MISCELLANEOUS REPAIRS / REPLACEMENT OF UG CABLE, GARDEN LIGHTS AND CALIBRATION OF RELAYS AT NSB, NCS, MES PERSONNEL ACCN INCLUDING MMT AREA UNDER AGE E/M NO-I OF GE(U-I) VISAKHAPATNAM.
2023_MES_583086_1
8514/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer Utility-I
₹68,000
Yes
28 Mar 2023
25 Feb 2023
22 Mar 2023
25 Feb 2023
20 Mar 2023
13 Mar 2023
Amount
S&F danger notice plate of size 25 x 20 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT including dismantling old one complete all as specified and as directed.
S&F danger notice plate of size 20 x 15 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for LT including dismantling old one complete all as specified and as directed.
M&L straight through joint, heat shrinkable type complete with jointing materials and accessories, suitable for 1.1 KV, 3.5 core XLPE aluminium conductor cable of size 400 Sqmm including taking down old joint complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl Item No. 3.00 but suitable for cable of size of 3.5 core 185 to 300 Sqmm
All as per Sl Item No. 3.00 but suitable for cable of size of 3.5 core 90 to 150 Sqmm
All as per Sl Item No. 3.00 but suitable for cable of size of 3.5/4 core 25 to 70 Sqmm
S&F MCCB 4 pole 250 Amp, breaking capacity 36 kA, Ics = 100% Icu, microprocessor release type with adjustable overload setting (0.4-1.0 ln), adjustable short circuit setting (1.5-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand / Indo Asian (Optipower)
All as per Sl item No. 7.00 above but 400 Amp
S&F MCCB 4 pole 63 to 100 Amp, breaking capacity 36 kA, Ics = 100% Icu, thermal megnatic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing MCCB complete all as specified and as directed. Make :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand / Indo Asian (Optipower)
All as per Sl item No. 9.00 above but 200 to 250 Amps
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 185 Sqmm, 3 core, laid in trenches / duct / on pole including taking down existing cable complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
All as per Sl. Item No. 11.00 above but for cable of size 120 sqmm x 3 Core
All as per Sl. Item No. 11.00 above but for cable of size 95 sqmm x 3 Core
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 400 Sqmm x 3.5 Core, laid in trenches / duct / on pole including taking down existing cable complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
All as per Sl. Item No. 14.00 above but for cable of size 300 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 240 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 185 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 95 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 70 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 50 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 35 sqmm x 3.5 Core
All as per Sl. Item No. 14.00 above but for cable of size 25 sqmm x 4 Core
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, of size 250mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Boring holes horizontally under road, manually, in soft / loose soil, without cutting / disturbing the existing road surface, suitable for inserting pipe of n exc. 100 mm bore at a depth 0.75 m to 1.0 m from road surface for passing of UG cable, getting out and disposal of soil to a distance not exceeding 50 m complete all as specified and as directed. Note:- GI Pipe shall be measured and paid separately.
M&L for cable route indicator for LT UG cable, 1100 Volt grade made out of 4mm thick MS sheet in round shape of dia not less than 200mm, embossed with LT Cable on it, bolted with 2 nut of suitable size at top of 40 x 6 mm MS flat iron of length not less than 1 meter, complete metal surfaces painted with 2 coats of synthetic enamel paint over a coat of primer & bottom of flat iron embedded in PCC 1:3:6 type C2 of size 200mm x 200mm x 500mm (400mm below ground level an 100mm above ground level), exposed surface of concrete painted with 3 coats of white wash including necessary earth work complete all as specified and directed.
S&F100 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection including taking down complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
All as per Sl Item No. 31.00 but 80 mm bore .
All as per Sl Item No. 31.00 but 50 mm bore .
M&L for taking out / jointing / cutting / welding work to loose or separated door / canopy / front & back sheet covers etc of existing LT panel and refixing the same to make opening and closing of door smooth including providing new nut-bolts, hinges, locking arrangement etc as required at site, fixing earth connections properly complete all as specefied and directed.
M&L for decarburizing / cleaning existing LT panel of various sizes consisting of bus bar & circuit chamber, metering chamber, CTs and relay chambers, cleaning with CTC and ensure proper decarburizing,checking the bus bar joints, bus bar and circuit spouts, current transformer, all connections, tightening of nut-bolts, thimbles, joints, cleaning and applying busbar Insulation tape to the bus bars, applying monoplast compound at the bus bar joints, supply & replacing defective / burnt nut-bolts, lugs and wire with new nut-bolts, lugs & wire of suitable size and reassembling & refixing the same complete all as specefied and directed. Note:- Cost of cleaning agents, insulating solution, bolts, nuts, washers, lugs, wire etc. shall deemed to be included in the unit rate quoted against this item.
M&L preparation of old painted surfaces of LT panels etc. by scraping rusted surface by sand paper & steel brush, rubbing, cleaning, brooming and making the surface smooth including spray painting with one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
S&F phase indicator lamps (Red, Yellow and blue) suitable for fitting in existing panel including taking down old one complete all as specified and directed. Make:- L&T / Siemens / GE / RR Micro / BCH / Schneider
S&F programmable numerical inverse time over current / earth fault relay suitable for VCB of capacity 11/12 KV including taking down old one complete all as specified and directed. Make:- ABB / Scheneider / Areva
M&L for calibration and testing of combined inverse time over current and instantaneous relay, checking and cleaning / decarburizing its moving and fixed contacts and ensure physical healthiness with visual check for healthy tripping of over current and earth fault, adjusting tripping time, flag setting, ratio setting, instantaneous time setting etc as per installed capacity of transformer to be saved on maximum, short circuit current in accordance with percentage impedance of transformer with artificial current injection on primary side with current injection machine of HT VCBs complete all as specified and directed by Engineer-in charge. Note : (i) Contractor shall provide all testing equipment, T&P and injection kit for testing and creating the artificial fault for testing the proper functionality of relays and instruments on designed settings & unit rate quoted against this item shall be considered to include all these aspects. (ii) Necessary test report of calibration shall be submitted by the contractor to Engr-in-Charge before claiming any payment against this item.
S&F in repair 1 x 8 watt LED bollard light fitting, bamboo shape, IP-65, including hot dip galvanized pole, driver, all fixing arrangement etc. & electrically connecting complete all as specified and directed. Make:- Crompton / HPL / Havells / Bajaj
S&F 25 watt LED post top lantern with clear acrylic diffuser, pressure die cast aluminium housing, IP-65 (minimum), high efficient constant current electronic driver including electrically connecting and taking down old one complete all as specified and directed. Make :- Crompton / HPL / Havells / Bajaj
S&F weather proof cable junction box of size not less than 130 mm x 130 mm x 77 mm with terminals, IP 66 (minimum), suitable for outdoor installation, suitable for 25 to 16 sqmm cable, including fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers & taking down complete all as specified and directed. Make :- Hensel / Sintex Industries Ltd. / C&S electric Ltd.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling existing old earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm for outdoor end termination, heat shrink type joint complete with jointing material and accessories including taking down old one complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl. Item No. 46.00 above but suitable for cable of size 95 sqmm x 3 Core
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 95 sqmm for straight through, heat shrink type joint with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
All as per Sl. Item No. 48.00 above but for cable of size 120 to 180 sqmm
SRI SRK ENGINEERS
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
SAMPATH ENTERPRISES
M/S CHANDRA ENGINEERS AND CONTRACTORS
jyothi constructions
MSN ENGINEERING WORKS
SRIESWARI ENTERPRISES
VENKATESWARA ENGINEERS AND CONTRACTORS
SVG SUPPLIES
MONITOR ENGINEERING WORKS
CHINNI ELECTRICAL ENGINEERING WORKS
REAL ENGINEERING WORKS
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .