| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹99.9 L+₹6.3 L (6.75%)Rejected-Finance | L2 | Rejected-Finance second lowest |
Tender Value
₹87.6 L
EMD Value
₹50,000
Closing Date
23 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical Division Harbour
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
Electrification of 120 tons/day capacity Tube Ice Plant at Sakthikulangara Fishing Harbour
2022_HED_503695_1
28/HEED/2022-23/S
Open Tender
Electrical Works
Item Rate
120 days
kollam
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
₹50,000
14 Dec 2022
16 Aug 2022
25 Aug 2022
16 Aug 2022
23 Aug 2022
16 Aug 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
Supplying and fixing IP65 thermoplastic circuit breaker boxes with metric knock out for cable entry , 1 rows 12 modules size 295x333x129 KV 9112 M with PE+N terminals. HENSEL or equivalent make
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supply and filling HSD oil
Supply and providing laminated drawings of electrical layout,schematic drawing etc on good frame work and placed in a conspicuous location for clear vision
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 15652/2006
Supply and providing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/wall bracket fillled with fine sand, painting the frame work/floor stand including making good the damages, colour washing etc.as required.
Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Supplying and fixing Cat 6 RJ 45 Frame on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supplying and fixing Cat 6 RJ 45 computer socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
Labour for making HT cable joints and end terminations. Beldar
Labour for making HT cable joints and end terminations. Cable jointer
Making thermal insulation on exhaust piping 100mm thick (using glass wool & Aluminium cladding)
Supply of 3 core 185 sq mm 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard.
Supply of the standard outdoor end termination kit comprising stress cum semi conducting pad,cap,rain shield,self bonding Insulating tape, sliding case, leakage current collector, protective corrugated hose pipe, boot, earth continuity connection (with 3 cores only)earthing lug (with 1core kit over lay) adhesive cum solvent PVC (NA) tape,Silicon grease,Aluminium crimping lug, Aluminium oxide cloth,nylon string, copper binding wire, hose clamp and bi-metallic washer
Supply of the standard Indoor end termination kit comprising stress cum semi conducting pad, sliding core,self bonding insulating tape, boot (with 3 core kit), earth continuity connection (with 3 core kit),earthing lug (with 1 core kit), adhesive-cum-solvent, PVC (NA) tape,Silicon grease, Aluminium crimping lug,Aluminium oxide cloth, nylon string,copper binding wire, hose clamp and bi-metallic washer
Providing and fixing 10.00 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 400 sq mm
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 240 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle MAIN panel board of size 1900x1700x800mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over a coat of epoxy primer, having vertical bus bar chamber, vertical cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x4.4mm MS channel provided at the bottom as support and comprising the following. Incomer: 1.KSEB Supply- 1250 A, 4 pole, manual draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA-1No , 2. 630 A 50 KA 4 pole manual draw out type micro processor based over load instantaneous SC ,delayed SC and ground fault protection with mechanical inter lock - 1 No. Stand by Low Set E/ F Relay- 1 Nos Neutral CT Extra current limiting - 1 No Outgoings:- 1000 A, 4 pole, manual draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50 kA-1No 200A TPN MCCB 35 KA -2 No with 230V shunt release - 400A TPN MCCB 50 KA-1 No 100A Neutral Link - 4 Nos Busbar chamber:- 1250A busbar chamber with 1250A TPN copper Bus Bar fitted on epoxy insulator. Switch interconnections to be done with suitably rated solid copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the MCCB and bus bar is also to be carried out using same size and materials used as bus bar. Internal Earth Bus shall be 50x5 mm copper strip Metering and Indication:- Smart demand controller (make Schnider or equivalent), RS 485 to Ethernet converter and SMP power supply PM7230 + EGX300 Integrated Gateway Server with port, accuracy class 1 - 1 No, Panel surface mounting 96 Sq.mm, LED Multi-function meter with RS 485 communication port having three line display to read Voltage,Amps,kVA,kVAr,PF and frequency of make SCHNEIDER or equivalent suitable for 415V,50Hz- 2Nos, 1000/5 A Epoxy wound CT 3 Nos , 650/5 A Epoxy wound CT 3 Nos,160/5A Bus bar mounting type tape wound C.T class1 for low set earth fault relay and 4A SP MCB C Curve (Cat B)- 12 Nos.LED phase indication lamps for KSEB and DG RYB-2Set. 32A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters for ACB / MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 50x5 mm copper strip with two earthing points at bottom side.
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle SUB panel board of size 1250 x 1450 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over two coats of epoxy primer, having one vertical bus bar chamber, three vertical and one horizontal cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following. Incomer:-200A, 25kA FP MCCB setted to 160A and rotory drive kit including BUC handle and shunt release with auxiliary contact- 1No Outgoings:- 63 A TP MCCB 25 KA setted to 50A -4Nos with rotary handle and 63 A two way disconnectable type neutral link suitably connected 40 A FP MCCB 16 KA setted to 32A - 1No with rotary handle and 32 A two way disconnectable type neutral link suitably connected. All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) Busbar Chamber: Busbar chamber with40 X5mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using insulated solid Copper strips of suitable size supported using epoxy insulators and outgoing with suitable rated solid copper conductor as required. Protection :- ELR with CBCT current setting 0.03A to 1A with time setting - 1 No Metering and Indication:- Panel surface mounting 96 Sq.mm, LED Multi-function meter with RS 485 communication port having three line display to read V,A,kVA,kVAr,PF and frequency of make SCHNEIDER or equivalent suitable for 415V,50Hz- 1Nos, 200/5 A Tape wound CT 3 Nos , and 2A SP MCB C Curve -7Nos ,Phase indication lamp - 3 Nos 63A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters and quarterturn key lock for MCCB cubicles,meter chamber and front openable bolted type bus bar covers, cable chamber and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 38x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule) ,
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supply, conveyance and fixing 40 A, 25 kA (Ics=100%Icu), 3 pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required
Supplying 20 W LED Tube with box type fixtures Essential LED tube 1200 mm 20W 865 T8 API Philips or equivalent
Supplying LED luminaire Philips WT 401 C LED 40S - 6500 PSU L 120 IP 65 or equivalent
Supply and fixing 5W/ 9 W LED ,BC, lamp OSRAM or equivalent
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply of single phase heavy duty exhaust fan dia 450mm,1400 rpm ALMONARD OR Equivalent in metal frame
Supply of Exhaust fan 305mm sweep single phase, heavy duty 1400 RPM, Almonard or Equivalent in metal frame
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supply of Keselec Schreder make SID or equivalent Street light luminaire, 20W LED, IP66 optical & control gear compartment, die cast aluminium painted housing,anti UV Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 105 Lumen/W at Ta 25C. Lifetime residual flux @ Tq 35C @ 50,000 hours = 70%, Ta = 50C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700K).
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing tinned 25x3mm copper strips having sufficient number of holes of 3/6mm dia as required on surface of wall using nuts & bolts as earth bus
Supply and fixing IP 65 Thermoplastic circuit breaker boxes 3 row 36 module 295 x 583 x 129 mm MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.4way (4+12) Double door
Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429 / 1969.
Supply installation,testing and commissioning including getting approval from KSEI of 3 phase,415 V 400kVA/320 KW Diesel Generator set with standard control panel AND AMF, radiator cooled diesel engine 1500 rpm with CPCBII approved acoustic enclousure and standard accessories coupled to brushless self excited Alternator rated 400 KVA at 415 volts conforing to IS/IEC 60034-1mounted on Channel Iron Base Frame complete with Fuel Tank (Prefe rred make: Engine CUMMINS, KIRLOSKAR,CATERPILLER; Alternator : BHEL EML, KIRLOSKAR, STAMFORD. Include charges for transportation of 3PH,415V AC 50Hz 320KW/400 KVA, Diesel generator set to Sakthikulangara ,erection and commissioning of Diesel Generator set including installation over plinth, positioning,testing and commissioning including documentation and getting approval from Electrical Inspectorate .
Supply,installation,testing and commissioning of 750 KVA UNITISED SUB STATION 11000/440V, 3 phase, 50 Hz, vector Dyn11 Transformer with offcircuit tappings from +5% to -10% in steps of 2.5%, changeable on offcircuit by tap links provided ,HT& LT cable,12kv Load break switch panel,Cast resin air cooled transformer with associated protection,Electronic meter with TOD metering facility, terminal box suitable for 4 runs of PVCA cable including the base channel and steel fabricated housing. Make - INTRANS/ABB/SCHNEIDER or equivalent
Exhaust piping with 150mm MS Class B pipe , heavy duty bend and flexible connector, MS support etc.including 2 coat heat resistant painting.
Supplying metal shutters suitable for 305/405 mm sweep heavy duty exhaust fan
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size
Supply of 1 pair 11 kv rubber hand gloves of approved make
Preparation of all drawings, submitting and getting approval from electrical inspectrate,submitting of completion certificates,arranging inspection,getting sanctions and energisation certificate,test reports etc.All statutory payments will be reimbursed on production of original receipts
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In lime mortar
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80m dia but not exceeding 300 mm dia
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
gnarakkal brothers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_721480.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .