| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹29.1 L+₹1.4 L (5.24%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L2 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 3 | L3₹31.7 L+₹4.1 L (14.7%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 4 | L4₹33.1 L+₹5.5 L (19.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Rejected for acceptance being not lowest. | |
| 5 | L5₹36.8 L+₹9.1 L (33.1%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L5 | Rejected-Finance Rejected for acceptance being not lowest. |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
6 Jul 2020, 6:00 pmClosed
GE (AF) Jamnagar No.2
GE (AF) Jamnagar No 2, Air Force-II, Udhyog Nagar, Jamnagar-361004
OUTSOURCING OF RESOURCES FOR MGT AND OPERATION OF E/M INSTALLATIONS AT TECHNICAL AREA AND REPAIR/MAINT WORK FOR PUMP SET AND MOTOR CONTROL PANEL AND CONTROL VALVES INCLUDING REPAIR TO DUAL MEDIA FILTER AT AFS UNDER GE (AF) JAMNAGAR NO 2
2020_MES_348654_2
8250/E8
Open Tender
Miscellaneous Works
Works
335 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹73,000
Yes
27 Aug 2020
19 Jun 2020
7 Jul 2020
20 Jun 2020
6 Jul 2020
20 Jun 2020
Amount
General Notes: - (i) Contractor’s special attention is invited that Estimated cost for Management & Operation of E/M Installations at Technical Area and repair/maintenance work for pump set & Motor, Motor Control panel and control valves including repair to dual media filter Rs.29,96000.00 based on prevailing rate of Schedule of Minimum fair wages. If the quoted amount is less than the amount the work, then the lowest bidder will have to deposit FDR/BGB in favour of Accepting Officer within 07 days of opening of Financial Bid for the difference in estimated cost & quoted amount. (ii) In case the said FDR/BGB is not submitted within stipulated period as mentioned above, the contractor shall be banned for 06 months & their bid will be rejected and finance bid will not be opened. FDR/BGB submitted shall be released only after satisfactory completion of work on submission of proof of payment that all the person deployed under this contract has been paid not less than Schedule of Minimum fair wages as mentioned under Note No.4.2 here in after.
Outsourcing of resources for Manning and Operation of water supply installation located at 12 End Open Well Technical area at air force station Jamnagar for continous operation (as per schedule) of various assests such as Pumps, motors, chemical dozing plant , dual media filter by back washing on daily basis and water supply headers to provide water supply to various users inside technical area by providing one fitter general mechanic (FGM), with minimum 2 years experience for operation of pumping and distribution system , per shift of 8 hours for 2 shifts per day (including sunday and National holiday).
The water supply installation comprising of following components (a) Submersible multi stage pump set directly coupled with 30HP 3 phase electric motors- 2Nos. (b) NRV 100mm = 02 No. (c) Sluice Valve/ Butterfly valve 100mm = 02 No. (d) Dual Media filter = 01 No. (e) Motor control starter panels = 02 Nos. (f) Sumersible pump set 7.5 HP = 01 No. ( g ) Sluice valve/Gate valve/Non return valve = 11 Nos.
The Contractor will be responsible for routine/preventive maintenance of eqipments as mentioned avove , cleaning of surrounding area of the installation and the building, valve pits , earth pits , minor repair for leakage like providing gland packing, replacement of flange gasket and maintenace of control panel pumping set/LT panel and tightening of loose connections in panels etc. and routine/periodic maintenance of all installed equipment/components by following the maintenance schedule as per particular specification. The contractor and his opeartor must adhered to all instructions contained in Notes and Particular specification . Nothing extra has been admissible for routine/preventive maintenance as mentioned above.Non compliance of instructions contained in Notes and Particular specification may leads to recovery as deemed fit at the discretion of accepting officer.
Outsourcing of resources for Manning and Operation of water supply installation located at 06 End Open Well Technical area at air force station Jamnagar for continous operation (as per schedule) of various assests such as Pumps, motors, chemical dozing plant , dual media filter by back washing on daily basis and water supply headers to provide water supply to various users inside technical area by providing one fitter general mechanic (FGM), with minimum 2 years of experience for operation of pumping and distribution system , per shift of 8 hours for 2 shifts per day (including sunday and National holiday).
The water supply installation comprising of following components (a) Submersible multi stage pump set directly coupled with 30HP 3 phase electric motors- 2Nos. (b) NRV 100mm = 02 No. (c) Sluice Valve/ Butterfly valve 100mm = 02 No. (d) Dual Media filter = 01 No. (e) Motor control starter panels = 02 Nos.(f) Sumersible pump set 7.5 HP = 01 No. (g ) Sluice valve/Gate valve/Non return valve = 11 Nos.
The Contractor will be responsible for routine/preventive maintenance of eqipments as mentioned avove , cleaning of surrounding area of the installation and the building, valve pits , earth pits , minor repair for leakage like providing gland packing, replacement of flange gasket and maintenace of control panel pumping set/LT panel and tightening of loose connections in panels etc. and routine/periodic maintenance of all installed equipment/components by following the maintenance schedule as per particular specification. The contractor and his opeartor must adhered to all instructions contained in Notes and Particular specification . Nothing extra has been admissible for routine/preventive maintenance as mentioned above.Non compliance of instructions contained in Notes and Particular specification may leads to recovery as deemed fit at the discretion of accepting officer.
Outsourcing of resources for Manning and Operation of water supply installation located at Vijay well pump house, Open Well and bore well inside technical area at air force station Jamnagar for continous operation (as per schedule) of various assests such as Pumps, motors, chemical dozing plant ,dual media filter by back washing on daily basis and water supply headers to provide water supply to various users inside technical area by providing one fitter general mechanic (FGM), with minimum 2 years of experience for operation of pumping and distribution system , per shift of 8 hours for 3 shifts per day (including sunday and National holiday).
The water supply installation comprising of following components (a) Centrifugal multi stage pump set directly coupled with 22 KW 3 phase electric motors- 2Nos. (b) NRV 100mm = 02 No. (c) Sluice Valve/ Butterfly valve 100mm = 02 No. (d) Dual Media filter = 01 No. (e) Motor control starter panels = 04Nos. (f) Sumersible pump set 7.5 HP = 01 No. (g ) Sluice valve/Gate valve/Non return valve = 24 Nos.(h) Sumersible pump set 20 HP = 02 No.(j) FRP pressure vessel -01nos.(k) Pressure gauge -05 nos.
The Contractor will also be responsible for routine/preventive maintenance of eqipments and accessories , cleaning of surrounding area of the installation and the building, valve pits , earth pits , minor repair for leakage like providing gland packing, replacement of flange gasket and maintenace of control panel pumping set/LT panel and tightening of loose connections in panels etc. and routine/periodic maintenance of all installed equipment/components by following the maintenance schedule as per particular specification. The contractor and his opeartor must adhered to all instructions contained in Particular specification.
Outsourcing for Manning and Operation of Fire Fighting system located at WWR FIRE FIGHTING PUMP HOUSE Technical area at air force station Jamnagar for operation (as per schedule) of various assests such as centrifugal pumps, jockey pump, diesel engine driven pump including control valves(Hydrant and Sluice valve) by providing one fitter general mechanic (FGM), with minimum 2 years of experience for operation of fire hydrants, pumping and distribution system , for shift of 8 hours with 3 shifts per day (including sunday and National holiday)
The fire fighting installation comprising of following components (a) Centrifugal multi stage pump set directly coupled with 75HP 3 phase electric motor- 1Nos. (b) NRV 150mm = 02 No. (c) Sluice Valve/ Butterfly valve 150mm = 02 No (d) Jockey pump set directly coupled with 15 KW motor = 01 No. (e) Motor control starter panels = 02 Nos. (f) Diesel engine driven pump directly coupled with 92 HP motor = 01 No.(g ) Sluice valve/Gate valve/Non return valve =06 Nos.(h) Battery 180 AH -02 nos with charger (j) Fuel tank -01nos.
The Contractor will also be responsible for routine/preventive maintenance of eqipments and accessories , cleaning of surrounding area of the installation and the building, valve pits , earth pits , minor repair for leakage like providing gland packing, replacement of flange gasket and maintenace of control panel pumping set/LT panel and tightening of loose connections in panels etc. and routine/periodic maintenance of all installed equipment/components by following the maintenance schedule as per particular specification. The contractor and his opeartor must adhered to all instructions contained in Particular specification.
Notes for Item no.1 to 4: 1. Wage paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State/Central Government from time to time whichever is higher. The payment shall be made to the workers through a nationalised bank and the bank statement of fair wages as per minimum labour wages as mentioned above shall be submitted along with the RARs/FB for payments. 2. The contractor shall be responsible for the EPF, ESI, bonus, Safety etc. and insurance of all trademen employed by him as per existing Labour Rules/Acts/Regulations. 3. Contractor special attention is invited that payment of operator / labour shall be made only through Account payee cheque and same shall be deposited in Adhar link account of operator / labour. Documentary evidence for the same shall be submitted to Engineer -in-Charge before payment of RAR / Final bill.
Notes Contd ......../ 4. Contractor and his personnel detailed for manning of Pump house and Fire Fighting Pump House shall be responsible for serviceability of Pumpset,Diesel engine generating set, Valves. In case of any major fault occurs in above mentioned items, he will be report directly to concerned JE E/M / AGE E/M. Person deputed for operation will be responsible for minor maintenance such as checking of oil, checking of Diesel, oiling and greasing of Valves,Drawing disinfectant from MES and pouring it to dozing system to maintained required PPM level as per IS norms, informing MES and maintaing sufficient balance in storage tank for DG set as and when required, checking of battery terminal and cleaning of DG Sets,Pumpset,Valves cleaning of Pump house room and surrounding areas complete. 5. Necessary weekly off will be given to all the manpower employed for this schedule as per existing rules and regulation of state /central govt. and necessary replacement or reliver shall be provided by the contractor. Rates quoted for this schedule shall deemed to be include the payment of reliever also.nothing extra shall be admissible on this account.
Notes Contd ......../ 6. In case absence of any operator / workmen from any shift will be penalized with a penalty of double the rate quoted by the contractor in addition to the shift not taken in to consideration for payment. Attendant / Operator wanting leave will get it sanctioned before proceeding on leave along with the name of individual who will be performing his duty/shift in his absence. No replacement of operator/workmen without the knowledge of department will be allowed. 7. Safety equipment's, tools and first aid kit ,sanitization kit and hand gloves must be provided by the contractor to all tradesman without adding any extra cost to government.Initimation regarding this must be conveyed to Engr-in-charge and GE by the contractor in writing within 08 days from the date of commencement. 8.Log book (Sheet), Muster roll, duty roster, fuel consumption register, daily breakdown register, attendance register and other requisite registers shall be maintained by operator and get it signed by concerned JE, Engineer-in-charge and contractor on daily basis and same shall be submitted monthly to accepting officer for inspection and other details as specified in PS.
Notes Contd ......../ 9.Operator should posses ITI certificate in respective trade with minimum 02 years experience for running of installation and well conversant with the Pump set equipment's with connected panel and opeartion of DG set and must produce qualification and experience certificates duly attested by gazetted officer. The attested certificate shall be submitted to accepting officer at the time of commencement of work. 10. Contractor should be responsible for maintaining parameter such as TDS & PH as per IS standard. Any deviation of results in comparision to IS standard may attract penalty @ 500/- per day per report. Contractor must keep daily record of various parameter ( TDS & PH) and put up to AGE E/M weekly for correctness . Any measuring instrument/kit required for measurement of parameters must be provided by the contractor to the operator. 11. Contractor / his operator will be responsible for continous running of the installations any failure due to negligence of operator may attract penalty @ Rs. 500/- per hour till restoration. 12. The routine/preventive measures as per Appx "A" of above equipment /plant deemed to be included in the unit rates quoted against this item.
Notes Contd ......../ 13. Contractor should provide proper dressing to all the operator as directed by Engr-in- charge.Non compliance of instructions with respect to dressing may attract penalty @ Rs.200/- per day per operator. Initimation regarding this must be conveyed to Engr-in-charge and GE by the contractor in writing within 15 days from the date of commencement. 14.Operator must inform JE/AGE concerned within half an hour in the event of breakdown or failure of Pumpset/motor and electrical panel and even leakage of pipeline.Delay on this part will be treated as negligence of operator , which can attract penalty and per note 13. 15. All necessary stationery required shall be provided by contractor as per sample , cost of this is included in the cost of item. Contractor must be responsible to maintain stock of chemicals for water treatment at all the times and must intimate to concerned JE/AGE three days in advance whenever active stock is about to finish.
Notes Contd ......../ 16.Contractor or his operator ensure handing/taking over of assest during change of shift , any part/component at installation found missing/damaged due to negligence will be treated as wilful damage and for this cost of replacement shall be recovered from contractor payment due.as per direction of Engr-in-charge. 17.Contractor is fully responsible for any kind of mishaps/accident occurred due to ignorance/mishandling /misfunction/negligence while on duty by contractor operator.at the installations. Necessary insurance,for all operator, as per ESI rules must be obtain by the contractor.Initimation regarding this must be conveyed to Engr-in-charge and GE by the contractor in writing within 15 days from the date of commencement. 18. Contractor is responsible for maintaining daily records for water distributed to users.Record should be put up to AGE E/M duly signed by contractor and JE E/M.Non -maintenance of records will attract penalty at @ Rs. 300/- per day. 19. The contractor and his workmen shall comply existing labour laws , IE Rules ,Factory act in totally.
Deployment of man power for Collecting the sample of water, on monthly basis, from different point such as under ground sump , open well, bore well for chemical testing of water from reputed Govt Laboratory or any Laboratory authorized by Government for iron content in water , PH value, Hardness, turbidity, chloride, fluoride and other parameters as per IS standard. Submitting the test report to Engineer-in-Charge on 5th day of every month complete all as specified and as directed
Deployment of man power for Collecting the sample of water , on monthly basis, from different point such as under ground sump , open well, bore well for bacteriological testing of water rom reputed Govt Laboratory or any Laboratory authorized by Government including arsenic test from reputed Govt laboratory .Submitting the test report to Engineer-in-Charge on 11th day of every month complete all as specified and as directed.
Supply only calcium hypo chlorite high strength chlorination chemical (65% - 70%) for water disinfectant in granular from in factory sealed HDPE Container 45 to 50 Kg Make :- M/S Sree Rayalaseema Hi-strength Hypo Ltd. Note: (i)Contractor must submit/produce test report with hologram for the each lot/batch supplied by M/S Sree Rayalaseema Hi-strength Hypo Ltd to Engr-in-charge (iii) Each drum must be affix with Hologram (ii) Contractor must submit in writing about the ordered qty, date of packing of each drum , batch no and nos of drums and date of dispatch either on his letter head or from authorised dealer letter head. to Engr-in-charge.(iii) Non submission and non availability of above information leads to rejection of drum/ entire lot for which contractor is wholly responsible.
Taking out existing sand filter media /gravel /sludge of filter media from filter beds at 10 LGPD Filteration plant ,stacking properly for reuse(depending on density ), depositing at site, as directed, at a distance not less than 50 m apart from the starting point complete all as speicifed and as directed.
Taking out existing stone pabbles of any size from filter bed at Filteration plant and stack at side for resue after cleaning/washing and regradation complete all as specified and as directed.
Supplying and laying filter media, sand mesh of following sizes laid dry in layers all as specified and directed by Engr in charge for following sizes :-
sillica quartz sand 1 mm size
sillica quartz sand 0.8 mm size
sillica quartz sand 0.6 mm size
Labour only for relaying of stone gravells /pebbles suitable for filter bed of filteration plant laid dry in layers all as specified and as directed by Engr in charge for following sizes :-
10mm to 25mm size
4 mm to 10 mm size
S & F in repair motor/pump protection relay din rail mounted suitable for AC 440V for protection against phase to phase balance,overload and phase failure complete as per existing rating all as specified and as directed by engr-in-charge.Make: Minilec cat part no D2 MPR3 or equivalent in siemens/L&T
S & F in repair din rail mounted current sensor relay 32-80 amps 6 pole suitable for AC 440/230 volts complete all as specified and as directed by Engr-in-chargeMake: Minilec cat part no. S2CTS 80 or equivalent in siemens/L&T
S & F in repair din rail mounted current sensor relay 16-40 amps 6 pole suitable for AC 440/230 volts complete all as specified and as directed by Engr-in-charge Make: Minilec cat part no. S2 CTS 40 or equivalent in siemens/L&T
S & F in repair din rail mounted current sensor relay 2-5 amps for AC 440/230 volts complete all as specified and as directed by Engr-in-charge Make: Minilec cat part no. S2 CTS 5 or equivalent in siemens/L&T
S & F in repair monitoring relays suitable for AC 230/440V, din rail mounted as per as per existing rating all as specified and as directed by engr-in-charge.Make: Minilec S2 CMR2 or equivalent in siemens/L&T
S & F in repair phase failure 1 C/O output relay suitable for AC 230/440V , din rail mounted as per existing rating all as specified and as directed by engr-in-charge.Make: Minilec VSP D1 or equivalent in siemens/L&T
S & F in repair 3 pole contactors, AC 3 rating power contactor , 415 volts capacity 32A/15.0KW 1NC aux. contacts - 24 V AC coil suitable for motor operation complete all as specified and as directed by Engr-in-charge. Make:ABB code no:A30-30-01 or equivalent in L&T/Schneider/Siemens
S & F in repair 3 pole contactors, AC 3 rating power contactor , 415 volts capacity 37A/18.5KW or 40A/18.5KW 1NO aux. contacts - 24 V AC coil suitable for motor operation complete all as specified and as directed by Engr-in-charge. Make:ABB code no:A40-30-10 or equivalent in L&T/Schneider/Siemens
S & F in repair 3 pole contactors, MN X 40 power contactor , 415 volts capacity 40A/18.5KW 1NC aux. contacts - 24 V AC coil suitable for motor operation complete all as specified and as directed by Engr-in-charge. Make:ABB code no:A40-30-01 or equivalent in L&T/Schneider/Siemens
S & F in repair 3 pole contactors, AC 3 rating power contactor , 415 volts capacity 26A/11KW 1NC aux. contacts - 24 V AC coil suitable for motor operation complete all as specified and as directed by Engr-in-charge. Make:ABB code no:A26-30-10 or equivalent in L&T/Schneider/Siemens
S & F in repair 3 pole contactors, AC 3 rating power contactor , 415 volts capacity 65A/37KW 1NC aux. contacts - 24 V AC coil suitable for motor operation complete all as specified and as directed by Engr-in-charge. Make:ABB code no:A63-30-00 or equivalent in L&T/Schneider/Siemens
S & F in repair LED multi function meter with accuracy class 1.0 , flush mounting of size 96x96mm having function with provision of various parameter display for VOLT/AMPS/KW/KVAR/KWH/RUN HOURS /ON HOURS /Maximum demand (KW & KVA) and connectinf complete all as specified and as directed by Engr-in-charge. Make: L&T cat no WL442010OOOO or equivalent in Selec/ABB
S&F in repair stainless steel bourdon type pressure gauge dial type 0 -25 Kg/cm2 range with a stainless steel body complete including all necessary GI pipe connection fittings / cutting / jointing all as specified and directed by Engr In charge. Make: Guru/Feibeg/omega
S & F in repair HRC fuse link , DIN mounted of current capacity 63 amps confirming to IEC-60269-2 complete all as specified and as directed by Engr-in-charge . Make: HPL/Havells/ABB/L&T
S & F in repair HRC fuse link , DIN mounted of current capacity 100 amps confirming to IEC-60269-2 complete all as specified and as directed by Engr-in-charge . Make: HPL/Havells/ABB/L&T
S & F in repair HRC fuse link , DIN mounted of current capacity 125 amps confirming to IEC-60269-2 complete all as specified and as directed by Engr-in-charge . Make: HPL/Havells/ABB/L&T
S & F in repair MCCB 250 amp 4 pole,35 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator to be fitted in existing panel complete all as specified and as directed by Engr-in-charge . Make: Schneider/Legrand/ABB/L&T
S & F in repair MCCB 200 amp 4 pole,35 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator to be fitted in existing panel complete all as specified and as directed by Engr-in-charge. Make: Schneider/Legrand/ABB/L&T
S & F in repair MCCB 125 amp 3 pole,35 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator to be fitted in existing panel complete all as specified and as directed by Engr-in-charge . Make: Schneider/Legrand/ABB/L&T
S & F in repair MCCB 100 amp 3 pole,35 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator to be fitted in existing panel complete all as specified and as directed by Engr-in-charge . Make: Schneider/Legrand/ABB/L&T
S & F in repair MCCB 160 amp 3 pole,35 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator to be fitted in existing panel complete all as specified and as directed by Engr-in-charge . Make: Schneider/Legrand/ABB/L&T
S & F in repair rubber coupling bush suitable for centrifugal pump set 75HP/40 HP/30HP as per existing dimension complete all as specified and directed by engr-in-charge
S &F in repair rigid shaft coupling made out of steel material,corrosion resistant , rated for maximum drive horse power suitable for Pump set coupled with 75 HP electric motor
S &F in repair rigid shaft coupling made out of steel material,corrosion resistant , rated for maximum drive horse power suitable for Pump set coupled with 20/30 HP electric motor
M & L for preparation of old painted exposed surface of Centrifugal pump/monobloc set of capacity 20HP, with suction line of any size from UG sump to Pump set & delivery line from pump set to wall/pit as observed inside plant room , operating valves(Non return valve/Sluice valve/Gate Valve ) any size by removing dust, dirt, oil, grease etc & and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as approved colour using spray gun and writing SM/ MES No to pump sets with white paint complete all as specified and directed by Engr-in-Charge.
M & L for preparation of old painted exposed surface of Centrifugal pump/monobloc set of capacity 75HP, with suction line of any size from UG sump to Pump set & delivery line from pump set to wall/pit as observed inside plant room , operating valves(Non return valve/Sluice valve/Gate Valve ) any size by removing dust, dirt, oil, grease etc & and painting with two coats of synthetic enamel paint of superior quality as per existing colour or as approved colour using spray gun and writing SM/ MES No to pump sets with white paint complete all as specified and directed by Engr-in-Charge.
Supply only Bleaching Powder Gde-I quality contains 20 to 25 % active chlorined ISI marked all as specified and directed by Engr-in-Charge
Supply only Potash Alum crystal type or Water Soluble Alum Crystals as a flocculant for water purification cpmplete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6.3mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge
M&L for repair to Diesel engine opearted at 1800 RPM of cap 92HP/68KW Make: Kirloskar installed at WWR fire fighting pump house Make: Mather & Platt with taking out and repair/replacement of defective parts as under:
Diesel filter element with gasket
Inhibitor corrosion,tube water bypass & water outlet
Air cleaner element
Engine oil filter element complete
Air filter(inner & outer)
Fuel filter bowl,pre element & micro element
Solenoid switch with wiring complete
Governor cable both inner and outer including RPM adjustment assembly
Set of ring set,dowel for connecting rod,bolt for connecting rod,conneting rod assembly and joint for gear assembly
Taking out choked radiator from engine ,drain out coolant and descaling and cleaning with cleaning agent,cleaning of fins by applying pressuried air using blower including replacement of rubber housing set complete
Taking out nozzles (06 nos) from engine, transporting to auth workshop and overhauling of nozzles complete incl replacement of nozzle kit,caliberation with pump and plunger,reassembling and refixing complete
Taking out old/unsv engine belt and replacement of grooved belt complete
Coolant oil Make:Castrol/Valvoline/Servo
Draining out old unsv engine oil from chamber , cleaning of oil sump complete and filling of new oil 15W40CH4 confirming to specification. Make:Castrol/Valvoline/Servo
Taking out all leaked/deterioted rubber hoses of engine and replacement of hose pipes including clamps complete
Taking out old unsv fuel pipes and replacement of new nylon reinforced PVC fuel pipes with threaded sockets complete set, oil seal, seal O ring, screw captive washer cap
Scraping of old existing paint, oil from body of alternator ,radiator, engine ,base frame including exhaust pipe/silencer, preparation of surface and filling of cavity using filler material and spray painting to complete pump set and motor set alongwith all accessories including fuel tank with two coats of super enamelled paint of superior quality as approved by AGE E/M and writing of MES/SM No. using black paint of suitable font of letters in background of white paint complete all as specified and as directed by Engr-in-charge
Servicing/reparing of diesel engine driven pumping set with discharge cap 160m3/hr, Head:70mtr with replacement of bearing(DE/NDE),worn out gland packing ,replacement of oil,gasket,water seal, gland bush and painting of pump set complete all as specified and as directed by Engr-in-Charge
M&L for fabrication & fixing in position mild steel work for covers, supporting clamps of pipe, ladders, railing of over head water tank, under ground sump , Open well & water supply installation fabricated with mild steel section such as angle, flat, Tee, nut & bolt etc etc, cutting, welding cold or hot drilling holes in any shape or size and fixing arrangement, including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete using steel section of Fe 290 Grade -165 including dismantling of old steel work all as specified and directed by Engr-in-charge.
MADHAV ENTERPRISE
Hirachand Sunderji and co
jagdish machinery stores
Ravi enterprise
M/S Badri Electicals
M/s Balaji Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .