Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.5 L+₹3.9 L (16.7%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹30.0 L+₹6.4 L (27.2%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹30.3 L+₹6.7 L (28.6%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹33.1 L+₹9.5 L (40.5%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance Rejected |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehu Road, Pune
GE Dehu Road, Pune
REPAIRS AND COMP MAINT OF ST LIGHT AND ST LIGHT DSTR FOR CQSAV DEMPSY ROAD UNIT 147 AND STATION HEAD QTR AND ADJACENT AND REPAIRS AND COMP MAINT OF ST LIGHT AND STLIGHT DIST FOR COD AND FAD PERMTR ASHOK NGR GARDEN CITY AND ADJACENT GE DEHU ROAD
2023_MES_600679_1
8782
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Dehu Road, Pune
Pl refer tender documents
8 documents required · 8 mandatory
₹500
GE Dehu Road, Pune
₹92,000
Yes
24 May 2024
3 Jun 2023
30 Jun 2023
3 Jun 2023
28 Jun 2023
16 Jun 2023
Amount
Comprehensive maintanence to functioning street light on street light poles, flood light on highmust, including the repair/replacement unsreviceable light fitting.Maintanence the unserviceable control panel,cable, junction box, over head /under ground distribution system complete all as directed. with the following location :- (i) ODTD Perimeter.(ii) ODTD depot inside (iii) ODTD unit line(iv)Sivaji Nagar (v) ODTD officer mess.(vi) Napal Line (vii) Sarvarta Nagar (viii) Indrani Darshan (ix) A-II,A-I, C-I,-II Pump house. Note: (a)Necessary spare,fitting,excavation other related work will be measured in respective items. (b) Necessary hairing tools,ladder ,hydralic ladder ,safty equiptment for electrician and helper for repair/maintanence street light,security light, highmust light arrange by the contractor and cost of heairing is deem to be included in above work.. (c) Taking down and refixing the fitting and fixture is also including the cost .
Comprehensive maintanence to functioning the Gate lights/ post top lantern lights /Garden light/ building security light including the repair/replacement unsreviceable light fitting.Maintanence the unserviceable control panel,cable, junction box, over head /under ground distribution system complete all as directed. with the following location :- (i) ODTD Perimeter.(ii) ODTD depot inside (iii) ODTD unit line(iv)Sivaji Nagar (v) ODTD officer mess.(vi) Napal Line (vii) Sarvarta Nagar (viii) Indrani Darshan (ix) A-II,A-I, C-I,-II Pump house. Note: (a)Necessary spare,fitting,excavation other related work will be measured in respective items. (b) Necessary hairing tools,ladder ,hydralic ladder ,safty equiptment for electrician and helper for repair/maintanence street light,security light, highmust light arrange by the contractor and cost of heairing is deem to be included in above work.. (c) Taking down and refixing the fitting and fixture is also including the cost .
Comprehensive maintanence to functioning street light on street light poles, flood light on highmust, including the repair/replacement unsreviceable light fitting.Maintanence the unserviceable control panel,cable, junction box, over head /under ground distribution system complete all as directed. with the following location :- (i) COD Perimeter.(i) FAD Perimeter..(ii) COD&FAD depot inside (iii) COD&FAD unit line(iv)Ashok Nagar (v) Garden city. Note: (a)Necessary spare,fitting,excavation other related work will be measured in respective items. (b) Necessary hairing tools,ladder ,hydralic ladder ,safty equiptment for electrician and helper for repair/maintanence street light,security light, highmust light arrange by the contractor and cost of heairing is deem to be included in above work.. (c) Taking down and refixing the fitting and fixture is also including the cost .
Comprehensive maintanence to functioning the Gate lights/ post top lantern lights /Garden light/ building security light including the repair/replacement unsreviceable light fitting.Maintanence the unserviceable control panel,cable, junction box, over head /under ground distribution system complete all as directed. with the following location :- (i) COD Perimeter.(i) FAD Perimeter.. (ii) COD&FAD depot inside (iii) COD&FAD unit line(iv)Ashok Nagar (v) Garden city. Note: (a)Necessary spare,fitting,excavation other related work will be measured in respective items. (b) Necessary hairing tools,ladder ,hydralic ladder ,safty equiptment for electrician and helper for repair/maintanence street light,security light, highmust light arrange by the contractor and cost of heairing is deem to be included in above work.. (c) Taking down and refixing the fitting and fixture is also including the cost .
Supply for repairing the following spares parts/accesories for functioning the light fitting of any type all as directed,.
Constant Voltage 30 DRIVER as per Havells part No-LSSCRX2118.Make : Havells ,Shakti,Philips
Constant Voltage 20 w LED DRIVER as per Havells part NoLSSCRX1837Make : Havells ,Shakti,,Philips
Constant Voltage 24 V 2 A DRIVER as per Havells part NoLSSLNW0151Make : Havells ,Shakti,,Philips
Constant Voltage Led Driver up to 60Was per Havells part NoLSSLNW0252Make : Havells ,Shakti,,Philips
Integral decorative LED post-top 25W 5700K energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire all as directed. Make Havells,Philips,wipro
Flood light lumunaire 120W 5700K (WB) with high pressure die cast housing with IP66,surge protection light 100 watt netural warm white, all as directed. Make Havells,Philips,Shakti,
LED fittings 60W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.Make Havells,Philips,Shakti,
LED fittings 70W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.Make Havells,Philips,Shakti,
LED fittings 30W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.Make Havells,Philips,Shakti,
LED fittings 20W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.Make Havells,Philips,Shakti,
LED fittings 20W 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.Make Havells,Philips,wipro
LED fittings120W Neo N 5700K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.Make:Havells, Shakti,Philips
S&F inreplacement of rigid non metalic PVC conduit 20mm dia exclsive of boxes (junction/terminal) but inclusive of all Tees / bends /elbowes/reducer/bell mouth tubes ends and fixing accessoeriers coupler , lock nuts , sddles , pipe hook etc
Supply of fibre looping box with connector and MCB SP 2 to 6 Amps of size 150x150x100 mm including making connections all as specified and directed by . Make - United / National / Sintex
Supply only PVC insulated and unsheathed cable of size 1.5 Sqmm single core multistranded copper conductor FR cable 1100 V grade confirming to IS 694
Supply Reflector adhishive tape 25 mm with suitable for fixing in street light pole of colour red all as directe.
Aluminium cable lug 10/16/25/35 sqmm and supply with fixing the same all as directed.Make:-Dewel,M-Seal
Excavation in trenches Soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed .
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
Taking out LT Cable of any size(10 sqmm 2/4 core to 35 sqmm 3.5 core) for reuse or under Schedule of credit to contractor. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
Relaying of LT Cable of any size obtained from item no 5 as per site requirment and making connections as specified and directed by Eng in charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
supply ,Laying ,commossionong,testing in repair UG cable XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with stranded aluminum conducter of following sizes:- Make :- Havells/ Polycab/ Gloster
All as per item no 11 here in before but size of cable 10 Sqmm x 2 Core
All as per item no 11 here in before but size of cable 16 Sqmm x 2 Core
All as per item no 11 here in before but size of cable 10 Sqmm x 4 Core
All as per item no 11 here in before but size of cable 16 Sqmm x 4 Core
All as per item no 11 here in before but size of cable 25 Sqmm x 4 Core
All as per item no 11 here in before but size of cable 35 Sq mm x 3.5 core
Taking out HDPE DWC Pipe of any size for reuse or under Schedule of credit to contractor. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
Relaying of HDPE DWC pipe of any size obtained from item no 8 as per site requirment as specified and directed by Eng in charge. Note:- Excavation is not included in quoted rate and will be measured & paid separately.
M & L in repair HDPE DWC pipe40 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :- Make:-Infra/Supreme/Prince
Dismentaling and Restringing OH line of ACSR conductors of any description which includes replacement 22 SWG aluminium binding wire,removing jumper connections, reconnection of binding wire & jumper connections after restringing complete upto the satisfaction of Engr-in-Charge. NOTE :- Each conductor span shall be measured & paid as one RM length.
Dismantling and taking down insulators of any size from dismantled/existing LT poles of any type or description complete all as specified and directed.
M & L for LT insulator, PIN type 1100 volts as per IS 1445, grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent.
Fixing only LT insulator, PIN type, 1100 volts grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent.
Fixing only shackle type insulator as per IS 1445 working pressure in 1100 volts, 100mm height, 115mm dia porcelain, vitreous, white or brown insulator including galvanised mild steel straps of size 31x5mm, washers, insulator bolts of size 14mm dia, washers and nuts, including taking down of u/s shackle insulators complete all as directed by Engr-in-charge.
M & L for shackle type insulator as per IS 1445 working pressure in 1100 volts, 100mm height, 115mm dia porcelain, vitreous, white or brown insulator including galvanised mild steel straps of size 31x5mm, washers, insulator bolts of size 14mm dia, washers and nuts, including taking down of u/s shackle insulators complete all as directed by Engr-in-charge.
Dismantling and taking down MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
Fixing only MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
M&L cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete.
Taking down unserviceable MCCB and Supply & fix in repair MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 10 KA ,Ics=100% Icu. Make : LEGREND/ BENLO/Sncheider/HPL
Taking down unserviceable MCCB and Supply & fix in repair MCCB 125 Amp, 4pole, 415 V,with breaking capacity 10 KA ,Ics=100% Icu. Make : LEGREND/ ABB/Sncheider/HPL
Taking down unserviceable MCCB and Supply & fix in repair MCCB 100 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ BENLO/Sncheider/HPL
Taking down unserviceable MCCB and Supply & fix in repair MCCB 63 Amp, 4 pole, 415 V,with breaking capacity 10 KA ,Ics=100% Icu. Make : LEGREND/ BENLO/Sncheider/HPL
S&F in repair Smart Integrated Solar All In One with > 140Lum/W, 09 Watt power Rating, MPPT Charge Controller, Tiltable LED panel,Including Lithinim battery Adjustable AIO mounting angle, MonoCrystalline Solar Panel, PIR motion Sensor, easy to install. MAKE :- Crompton,Havells,Bajaj,Jaquar
Taking down unserviceable GI pipe street light pole ,supply and installed hot dip Galvanized octagonal pole of height 7 mtr, top70 mm, and bottom 135 mm ,Top 70 mm made with 3mm thick Mounting base plate 250x Plate,fix on PCC foundation with foundation bolt 700mm long 250x12 mm with four nos foundation bolts with washer of size 16mm dia and 600mm long mm bolt,including street light bracket single arm minimum expoe lenght 1.5 mtrr length from poles withe pole cape complete as per manufacturer design.(PCC for foundation measured and paid in respected sch a"A" items)
Supply & fix cable jointing kit for 1100V XLPE grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 2 core 10/16 sqmm XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in-Charge. Make :- M-Seal/ Densons/ Dowells
All as item no 26 here in before but size of cable 25 to 30 sqmm,3.5/4 core
M & L to find out fault location in 11000 V /415 V UG Cable of any size by using cable fault locator directed by all as specified and directed by Eng in charge. Note:-Contractor must bring cable fault locator at site within 24 hours of intimation otherwise recovery @ Rs 1000/Hr will be charged after 24 hours.
M&L for repair of LT distrobution panel that includes welding to panel doors,reconnection of defective electrical connections(incoming and outgoing cables),cleaning of inner and outer surfaces,painting of inner and outer surfaces,reconnection of cables coming from transformers ,Replacement of defective voltmeters&ammeters ,Providing of Cable glands, spraying of Pesticides to remove gross, and cleaning & well surfacing of Transformer sorroundings all as specified and directed by Eng in Charge.
Material and labour for repair time switch 24 hrs for functioning street light including supply and fixing time awitch all as directed.Make Havells,L&T
Om Sai Enterprises
PREETI ENTERPRISES
metro electrical services
ONKAR ELECTRIC AND GENERAL STORE
Mahindra Electric Stores
N D ELECTRICAL
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .