Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹7.4 L+₹11,355 (1.55%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | - | Rejected-Technical CATEGORY NOT FULFIL |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
1 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur-342 011 (Raj)
REPAIR AND MAINT TO MES INSTALLATIONS AND CONNECTED MISC WORKS AT DEFENCE LAB JODHPUR
2022_MES_505547_1
8467/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹18,000
Yes
14 May 2022
3 Feb 2022
3 Mar 2022
3 Feb 2022
1 Mar 2022
15 Feb 2022
4 Feb 2022 - 11 Feb 2022
60 days
Amount
Servicing, Testing & Commissioning of Vacuum Circuit Breaker 11 KV by taking shut down and disconnecting electrical connections, removing of dust with blower cleaning of all movable/in movable parts, checking of all components, insulators/studs with megger and replacing unserviceale parts, adjusting the male/female bushings in proper spacing, greasing all parts, tightening nuts and bolts, reconnecting all electrical connections, testing, commissioning of VCB complete all as specified and directed by Engineer-in-charge. Note: Spares parts replaced with new paid saperately.
S&F Auxillary switch (6NO + 6NC) of VCB 630 Amps, 11KV including taking down unserviceable complete all as specified and directed by Engineer-in-charge.
S&F Power Pack with battery back up suitable to work on 110 volts supply for 33/11 KV VCB Panel including taking down old unsv complete all as specified and directed by Engineer-in-charge.
Supply and Fix Over Current and Earth fault protection relay suitable for 33/11 KV VCB Panel complete all as specified and directed by Engineer-in-charge.
Supply and Fix Master Trip Relay suitable for 33/11 KV VCB Panel complete all as specified and directed by Engineer-in-charge.
Supply and Fix in repair Digital Volt Meter for 33/11 KV alongwith control wiring suitable for complete all as specified and directed by Engineer-in-charge.
Supply and Fix in repair Digital Amp Meter for 33/11 KV alongwith wiring suitable for complete all as specified and directed by Engineer-in-charge.
S&F in repair LED indicator (R,Y,B) for 33/11 KV VCB, 110 Volt, with control wiring complete all as specified and dirceted by Engr-in-charge.
Servicing, Testing & commissioning the functioning of all existing LT ACB, and all others connected accessories and carrying out necessary maintenance such as applying grease, gel etc. including calibration of ACB, carrying out necessary repairs along with making suitable arrangements for testing of equipment and necessary instruments required for testing of relays installed in ACB at site complete all as specified and directed by Engineer-in-charge. Note: Spares parts replaced with new paid saperately.
Servicing, Testing & commisssioning the functioning of all existing Busbar connected from Transformers to VCBs and carrying out necessary maintenance such as applying grease, gel etc. at sitecomplete all as specified and directed by Engineer-in-charge. Note: Spares parts replaced with new paid saperately.
S&F in repair ACB 4 Pole, 415 volt with Thermal Magneticc Release (Manual Drawout Type) of Capacity 1250 Amp, complete all as specified and directed by Engr-in-Charge. Make:- Siemens, L&T, ABB, Schneider, Havells, IndoAsian or any other approved make.
Servicing/Repairing including fabricating, installing required aluminium busbar of suitable size at site and taking necessary color coding of sleeves inside busbar arrangements for ACB of 1250 Amp, 415 volt, 4 Pole complete all as specified and directed by Engr-in-Charge.
Supply & Fix Four pole contactor 25 to 30 Amp including taking down old unserviceable contactor complete all as specified and directed by Engineer-in-charge.
Supply & Fix Four pole contactor 35 to 40 Amp including taking down old unserviceable contactor complete all as specified and directed by Engineer-in-charge.
Supply & Fix MCB, Triple Pole, 32 Amp including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
Supply & Fix MCB, Triple Pole, 40 Amp including taking down old unserviceable complete all as specified and directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 1 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 3 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 4 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 7 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 10 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 12 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
M&L for Replacement of any defective capacitor of Rating 15 KVAR to meet the requirement for power factor complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement of unserviceable CT for LT with ratio (1000/5) all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
Supply and fix in replacement of unserviceable PT of 11 KV with similar existing size including control wiring all as per existing make complete all as specified and directed by Engineer-in charge.
Supply and fix in replacement of unserviceable CT for LT with ratio (1250/5) all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge.
Servicing, Testing & Commissionig of all existing APFC Panel including all others connected accessories and complete wiring required at site complete all as specified and directed by Engineer-in-charge. Note: Spares parts replaced with new paid saperately.
Supply and fix in replacement of unserviceable Power factor Control relay for 12 stage all as per existing make by commissioning and installing complete all as specified and directed by Engineer-in charge. Make:- Siemens, L&T, schneider, Epcos, Havells, IndoAsian, Legrand,ABB
Cleaning and necessary Repairing of broken Duct inside Power House Area by cement mortar (1:4) as per site reqmt after removing of cables from duct and relaying of cables as its original position complete all as specified and directed by Engr-in-Charge.
Supply and laying Synthetic Rubber insulating Mats 2.5mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes( 2m x 1m) complete all as specified and directed by engr-in-charge.
Supply and fixing Glow sign Board with size of (8 x 4)ft. on Fixing of MS square pipe including four LED tube light fitted inside board and making suitable connection to nearest point on the top of existing chajjas at site complete all as specified and directed by engr-in-charge. Note:- The Content marked on the Board is given by Engr-in-charge.
Supply and fixing Glow sign Board with size of (5 x 4)ft. on Fixing of MS square pipe on the top of existing RCC Pillar at site complete all as specified and directed by engr-in-charge. Note:- The Content marked on the Board is given by Engr-in-charge.
Material & Labour for marking the Pole Nos. on HT & LT pole with the use of ACP sheet of red color with size of 250mm x 300mm with writing font size min 5cm to 6cm long with the help of radium white color including fixing on pole with suitable clamp and nut bolt complete all as directed and given by Engr-in-charge. Note:- The content marked on the Sheet as per suitable design as per Qty is given by MES office.
Supply and fixing LED solar light fitting 24 watt, water proof, FRP body with integrated solar panel for outdoor purposes fixed on existing pole complete all as specified and directed by Engr-in-charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumiium conductor cable of size 120 sqmm to 185 sqmm complete all as specfied and directed by Engr-in-charge.
Repair/servicing of 11 KV breaker mechanically type 400 Amps, 36 KV, 3 phase, 50 HZ with shunt trip coil , 110 volt, motor single phase 230 volt with replacement of burnt items and testing complete all as specified and directed by Engr-in-charge.
S&F spring charge motor 230Volts AC for 33/11KV (ALSTOM VCB) including taking down old unserviceable spring charge motor complete all as specified & directed by Engineer-in-charge.
Supply & Fxing Trip coil 110 Volt suitable for 33/11 KV VCB panel complete all as specified and directed Engineer-in -Charge.
Supply & Fixing Closed coil 110 Volt suitable for 33/11 KV VCB panel complete all as specified and directed Engineer-in -Charge.
M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as specified and directed by Engineer-in-charge. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m for protection of earth strip and 32X6 mm GI strip up to 7.50 m length (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Anil Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .