CWE AHMEDABAD
CWE AHMEDABAD
SPECIAL REPAIR OF BLDG NO P-302/2,3 (COOK HOUSE AND DINNING HALL) OF BN NO 3 AT INF LINES JAMNAGAR.
2020_MES_365212_2
86717
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA JAMNAGAR
REFER TENDER
6 documents required · 6 mandatory
₹500
AGE I JAMNAGAR
₹77,800
Yes
10 Oct 2020
20 Aug 2020
8 Sept 2020
20 Aug 2020
7 Sept 2020
26 Aug 2020
20 Aug 2020 - 21 Aug 2020
Amount
Taking down chowkhat with not excceding 1.5 Sqm each (without taking off shutters from the frames.).
Taking down chowkhat with shuter excceding 1.5 Sqm but not exceeding 4sqm each.
Taking down steel windows frame & shuttes of any description not exc.1.5 sq.m each complete all as specified and as directed
Taking down steel windows frame & shuttes of any description exc.1.5 sq.m but n. exc.4 sq.m each complete all as specified and as directed
S&F Anodised Alum powder coated of any colour deco grill of 6 mm dia (powder coating not less than 50 micron) all as specified and directed at site.
S&F Aluminium anodised powder coated (powder coating not less than 50 micron) frame for doors, window & ventilators with shutter ,side hung type with out sash bars, including frames necessary joining cleats, glazing clips, anodised aluminium snap beading, screws, bronze anodised alumuminium fittigs such as stays, hinges type B-21 100 mm long suitable handle and locking system etc. glazing cleats, neoprene rubber beading fixed in frames (Neoprene rubber beading/Glazing will be measured and paid separately) complete all as directed by Engr in charge.Make :- Hindalco,indal,jindal,AP&Alumium ltd
S&F Neoprene rubber beading/packing complte all as directed by Engineer in Charge.
S&F Sheet glass, ordinary quality in square exc 0.50 Sqm each pane, 5.5mm thick fixed to Alumn section.complete.Make :- Saint Gobin,Asahi works,Modi
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers Make :- Saint Gobin ,Modiguard,Modi Float
S & F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood complete all as specified and directed.
S&F 30 mm thick Flush shutters, solid core constuction, with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats complete all as specified and directed. Make :-Goel Brothers,Raipur,Poineer Timber ,Goyal Industries ,Jain Doors,Inda Wood &Wood pdts
S&F 35 mm thick 2nd class hardwood factory made glazed & skeleton door shutter open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.20 (a) complete all as specified and directed.Make :-Goel Brothers,Raipur,Poineer Timber ,Goyal Industries ,Jain Doors,Inda Wood &Wood pdts
S&F Factory made solid panel PVC door shutter 30 mm thick (style) with wood free EPS , with 2,4 or 6 raised panel design with 2 mm thick PVC sheet on the front face and 2 mm plain colour PVC sheet on back face supplaying & fixing in the frame at site as per specification & drawing complete all as specified and directed.Make Rajshree Plstiwood,Sintex,Accucell,Dura Plast
Door Frame of size 50mm x 47mm made out of 5mm PVC sheet reinforced with M.S. Square tube wood colour PVC sheet & edges will be painted to match with printed sheet , suppling & fixing in opening as per specification & drawing complete all as specified and directed.Make Rajshree Plstiwood,Sintex,Accucell,Dura Plast
S & F 25MM thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specifed and directed. Make :-Goel Brothers,Raipur,Poineer Timber ,Goyal Industries ,Jain Doors,Inda Wood &Wood pdts
S & F in repairs 100mm Hasp and staple, safety type, alum with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples or with second class hard wood beadings all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 100mm long all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 250 mm long coplete all as specified and directed.
S&F Aluminium handles, cast type, anodised 100mm long.
S&F Stainless steel butt hinges 100 mm long all as specified and directed.
S&F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor
M&L Mild steel small articles such as clamps, hold fast etc conforming to Fe-410-0 or Fe-310-0.
M&L Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . Clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it . Core of concrete shall be firm, dust free and clean , laitance should be remove by etching with brushing. The surface shall be washed throughly with water and dryed before the application of boanding agent. Thereafter boanding agent shall be applied by the brush on the core of concrete structure as per manufacturars instruction. The bounding agent shall be Nitobound EP of FOSROC (or equalent chemical from SICA/MC BAUCHEMIE/DOCTOR BECK. The coverage area for the bonding agent shall be approximatly 2.6 Sqm/Litrs, and making good with CM 1:3 or PCC 1:1.5:3 type B0 (in and iclusive mix with waterproofing compound as per manufacturer instruction) as required thickness and match the finishing of the existing surface in ground floor.The thickness of slab up to 120 mm and depth of cutting not exc 200 mm, for chajja/projection in ground floor (thickness in to width measured) including scafolding and formwork as required..
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water , etc.
M&L for Rendering 10 mm thick in CM (1:6) on fair faces of brick/concrete wall surfaces, finished even and smooth without using extra cement.
M&L for rendering 15 mm thick in CM 1:4 on the external surfaces of brick work/Strone or concrete surface finishing fair and @ 3% of water proofing copound, even without using extra cement all as specified and directed.
M&L for rendering 5 mm thick in CM 1:4 on ceiling to be finished even and smooth without using extra cement.
M&L preparation of newly plastered surfaces of walls and applying two of oil bond distemper , onecoat of primer and birla white putty all as directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of Exterior emulsion paint 0n 0ne coat of primer and birla white putty all as directed..
M&L preparation of newly plastered surfaces of ceiling and applying two of oil bond distemper ,over one coat of primer all as directed.
M & L Complete romoval of existing treatment on wall and priming plastered and other surface with alkali resistant and applying two coats of exterior emulsion paint over one coat of priming and birla white putty all as directed.
M&L Complete Removal of existing treatment on ceiling rubbing and washing down and applying two coats of oil bound distemper over one coat of primer complete all as directed.
M & L Complete romoval of existing treatment on wall rubbing and washing down surface with two coats of oil bond distemper and on onecoat of primer and birla white putty all as directed.
M&L preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L Preparation of old plastered/unplastered surfaces of walls including cornices, pilasters etc and applying two coat of white wash on walls.
Preparation of old plastered/unplastered surfaces of ceiling including cornices, pilasters etc and applying one coat of white wash on ceiling.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&Lfor coloured Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors. set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 15 mm thick screed bed in CM 1:6 and make design pattern in floor complete all as directed by Engineer in Charge.Make Kajariya,somany,AGL Tiles,Johnson ,RAK Ceramic ltd
M&L for Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. Set over 10 mm thick cement plaster in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match Make Kajariya,somany,AGL Tiles,Johnson ,RAK Ceramic ltd
M&L 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, incl 15 mm thick screed bed in CM 1:6 all as specified and directed.
Moulding to granite (single or double) slab including rounding off edges for 18 to 20 mm thick slabs including grinding and polishing
M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver 10mm thick plaster in cement mortar (1:4).Make :- Make Kajariya,somany,AGL Tiles,Johnson ,RAK Ceramic ltd
S&F Non-skid ceramic tiles 7 to 8mm thick (square / rectangular ) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thck screed bed in CM 1:6 complete all as specified and directed.Make Kajariya,somany,Johnson
M&L Machine cut kota stone slab mirror polished 20-25 mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to mach the shad of the slab including rubbing and mirror polishing complete, including 15mm thick screed bed in cement mortat 1:6.
M&L for Machine cut kota single stone slab mirror polished 20-25 mm thick in riser of step , dado etc, piece machine polished laid over and jointed in cement slurry and pointed in gery cement and pigment to match the colour of slab,10mm thick rendering as in backing coat for skirting/dado in CM (1:4) with on wall surfaces complete as specified .
Removal of dimolished/rubbish obtained and laying at different location within a radious of 5 Km to be shifted to a place as shown at a avg distance of 3 Km, spread and levelled all as specified and directed. (Measurment will be loose stacked made at depositing place)
Dimolation of reinforced cement concrete any desctiption and in any position otherwise specialy provided and complete all as specified and as directed by Engr in Charge.
S & F 100 mm Precast prestrussed concreate slab all as specified and as directed by Engineer in Charge.
Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins,arches, pillars,etc.
M&L Brick work with sub class 'B' bricks straight or curved on plan ex 6 m mean radius built in CM 1:6 all as specified and directed
S&F inrepairs Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including floor pivots made out of 25 mm dia square bar all as directed.
S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed by Engineer-in-Charge.
M&L two coat of synthetic enamel paint over one coat of Red oxide,zinc chrome surface of any description over 10 cm in width or girth,not otherwise described.
Dismantling Glass fibre sheet/asbestos cement ( corrugated, semicorrugated ,etc.) sheets in roof coverings
S & F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick and colour having tensile strength of 50 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. Make TATA/JINDAL/INDAL
Taking up or down steel tubing and connections, including cleaning for refixing or removal to stack bore of pipe 15mm all as directed by Engineer in charge
Ditto all as per item no above but bore of pipe 20mm
Ditto all as per item no above but bore of pipe 25mm
S&F for 15 mm dia Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed by Engineer in charge
Ditto all as per item no above but bore of pipe 20mm
Ditto all as per item no above but bore of pipe 25mm
S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors.
S&F in repairs PVC(SWR) bend any radius, 110 mm dia.
S&F in repairs PVC (SWR) junction single, (Single T) equal with access door 110mm dia etc complete all as specified and directed by EIC
S&F inrepairs PVC (SWR) pipe 75 mm dia, conforming to IS 13592-1992 type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floors.
S&F in repairs PVC(SWR) bend any radius, 75 mm dia.
S&F in repairs PVC (SWR)75mm floor trap, plan with frating including jointing with solvent etc complete all as specified and directed by EIC
S&F decorative type Mirror of size 900x600 mm all as directed by Engineer-In-Chagre
S&F inrepairs 15 mm bore stop valves, cast copper alloy, screwed soen, high pressure with crutch or butterfly handlem screwed both ends for iron pipe or for unions and fixed.Make:Soma,Jaquar,Leader,Zoloto)
S&F in repairs bib tap long body with flange for 15 mm bore pipe cast copper alloy chromium plated fancy type , screwed down for iron pipe or brass ferrule.Cat No:8308 Prayag (Make:Soma,Jaquar,Leader,Zoloto)
S&F in Repairs Towel ring .Make:Soma,Jaquar,Leader,Zoloto
S & F in repairs brass 15 mm bore piller taps cast copper alloy, eith capstan headsm chromium platedm screwed down high pressure, with or without letterd Hot or cold with long screwed shanks and fly nutsm screwed for iron.Make:Soma,Jaquar,Leader,Zoloto
S& F inrepair stainless steel towel rail 300 mm longMake:Soma,Jaquar,Leader,Zoloto
S&F in Repairs 450mm long PVC Connection. Prayag Make:Soma,Jaquar,Leader,Zoloto
S&F Waste fittings,32mm brass , chromium plated for glazed ware sinks , basins , etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed
S&F 40mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.
S & F Solitire Range SS (304) grade Kitchen sink with drainage board over all size 914x460x203mm and Bowel size 405x354x203 x 1 mm thick (Prayag CAT PART NO 1239-D) glossy/matt finished, fixed to wall or cantilever brackets (Make : Jayana,Nirali,Neelkanth,Parryware)
S F Sinks made of stainless steel 1mm thick kitchen or aboratory with plugsm wasers and wastes including bedding in cement mortar on to drarf wall or including ficing cantilever brackets and connecting union to pipe overall size 495 mmx420mm boel size 410mmx330mmx160mm all as specifie and directed.(Make : Jayana,Nirali,Neelkanth,Parryware)
S&F in repairs counter top Vitreous china wash basin, white , excluding taps, waste, chain and plug and porcelain stopper but including mounting on granite slab 20 mm thick and fixed with brackets complete all as specified and directed (Make : Cera Parryware Neyvell,Jaquar,Rak ceramic)
S&F in Repairs Curtain Rod Aluminium body Decorative pattern colour as approved by Engr in Charge
S&F in repairs curtain rod bracket decorative type as approved by Engr in Charge
S&F Vitreous china squatting pan, 'Orrisa' pattern , size 580x440 mm white, with integral foot rests ( excluding flushing cistern and flush pipe).Make Cera,Parryware,Jaquar,Hinware,Johnson,RAK ceramic
S/F in repairs PVC valveless syphonic action type ,flushing cistern Low level white,with,with inlet ball valve ,float and handle 10 Ltr capacity including brackets.Make Cera,Parryware,Jaquar,Hinware,Johnson,RAK ceramic
Dimolation of old RCC over head tank any description and demolised material laid MD land all as specified and directed.
S&F Rotational moulded polyethyene triple Layer White water storage tank of White colour 1000 ltrs capacity hoisted and fixed in position all as specifed & directed by engr in charge.Make:- Sintex ,Polycon,Rotex
S&F 25 mm bore Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brassferrule and fixed Makr Leader,Neta,Zoloto
Demolition of PCC in ground floors and pavings exc 15 cm thickness (below or above ground level)
M&L 75 mm thick Cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in plinth protection
M&L 40 mm thk Cement concrete type B-1 , 1:2:4 (20 mm graded aggregate) as in subbase.
M&L plain cement concrete type D2, 1:4:8 100mm thick finished even and fair to receive top layer complete.
M&L Machine pressed ruber mouled precast concrete interlocking paver block with colour pigment any shape and size conform to IS 15658-2006 of 60 mm thickness M-35 Grade including 50 mm sand cushioning complete all as spesified and directed. Make:-Mahtab,Nitco,Ultra,Navya,Patel Fur Mart
Demolition of concrete of any description & in any position not otherwise specifically provided and removing debris outside MD Land complete all as specified and directed.
M&L Average 50 mm thk Cement concrete type C2 , 1:3:6 (40 mm graded aggregate) as in levelling course/padding with slope 1:40 all as directed
M&L for Rendering 10 mm thick in CM (1:3) on padding course, with WPC @ 3% by wt of cement all as directed.
M & L for water proofing treatment to non-accessible roof slabs by applying one coat of bituminous primer conforming to IS-3384 @ 0.30 litre/sqm and laying Actitic Polypropylene (APP) modified membrance , reinforced with non woven ployester, of 3.50 Kg/sqm (minimum, 3mm thick (minimum), with minimum 75 mm side overlaps and 100mm end overlaps and applying one coat of bituminous aluminium paint over APP membrane all as specified and directed by Engineer-in-Charge.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
Supply of integral water proofing compound
S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steelheavy duty and fixed
S & F in repairs yellow brass pipe (ISI Marked) for gas line fixed with wall proper clamp all necessary fittings and all specified and directed by Engr incharge.
S&F in repair Vitreous China urinals, half stall urinal (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) Make_Cera,Parryware,Neyveli Ceramic,Hindware,Jaquar,Johnson
Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross sectional area, single core, pvc insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC Concealed conduit of dia not less than 20mm and conduit accessories concealed in wall, ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes (with earth dolly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick Hylam sheet cover for fixing of switches, sockets etc including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed at site for the following :
One light/ Fan point controlled by one way switch.
One 5 Amps socket on same board with other switches.
One 5 Amps switch socket combination on independent board.
All as per item No-103 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed and PVC insulated mutistarnded conductor 2.5 Sqmm earth connectivety.
S&F switch piano flush type single pole one way 5 Amps 230 V.
S&F socket out let 3 pin 5 Amps flush type 230 Volts multipurpose,
All as per item No-106 above but 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) .
S&F socket out let 3 pin, 5 Amps, 230 Volt multipurpose flush piano type. .
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 120W ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface backelet ISI marked 2 to 3 terminal all as specified.
S&F lamp holder insulated body with back plate for battern fittings.including 7 Watts LED Retrofit lamp Make WIPRO/Havells/Philips
Supply& Fixing LED batten fittings 4ft 20 Watt (Min 1900 lumens) with clamps incl PVC gutties and flexible wire and connecting to ceiling rose complete Cat part No D532065 of make Wipro pr equivalent Bajaj/Havells/Jaquar/Philips.
Supply& Fixing LED Batten fittings 2ft 10 Watt (min 800 lumens) with clamps incl PVC gutties and flexible wire and connecting to ceiling rose complete Cat Part No D531065 of make Wipro pr equivalent Bajaj/Havells/Jaquar/Philips
S&F DB sheet metal enclosure 4 way TPN 415 volts IP43 double door for mounting MCBs.
S&F DB sheet metal enclosure 8 way SPN for mounting MCB double door.
S&F In repires MCB single pole and neutral 16 to 40 Amp all as specified and repturing capacity 10 KA complete Make :- Havlles /legarand/ABB
Supply and Fix Isolator TPN 63 Amps 415 Volts rupturing capacity 10KA.
S&F in repair MCB single pole 5 to 32 Amps C series all as specified and rupturing capacity 10 KA,
M&L for sub main wiring with two runs of 4.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/Multi stranded copper conductor drawn through PVC conduit and accessories concealed in walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 4.00 Sqmm single core as earth continuity wire all as specified and directed. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor incl conduit will be messured and paid as one unit length only.
Taking down & Refixing Exhaust fan 450mm sweep AC, 240 volts,metal body ,in same location after cleaning , greasing and painting with synthetic enamel paint by spreying including filling cavities with filler, one coat after cleaning all dusts etc and connecting up including provision of flexible wire from ceiling rose/connector to fan all as specified and directed by Engr in charge.
Taking down & Refixing Ceiling fan 1200mm sweep AC, 240 volts,Metal body ,after cleaning , greasing and painting with synthetic enamel paint by spreying including filling cavities with filler, one coat after cleaning all dusts etc and connecting up including provision of flexible wire from ceiling rose/connector to fan all as specified and directed by Engr in charge
S& F sheet metal enclouser with sockets plug top with 20 Amp MCBDP enclouser with a two pin and earth plug and sockets complete with one single pole MCB of 240 Volts Make ,Havells/Legrand /ABB
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe (light grade) and watering pipe 20mm bore GI pipe(light grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. complete all as specified and directed by Engineer-in-Charge.Note :- GI earthing wire of same size upto 7.5m shall deemed to be included into quoted rate
Supply, fixing, testing and commissioning 30W LED security light fitting with system output of 3000 lumens & with dedicated street light optics, System efficacy of greater than 100lm/W luminarie should have pressure die cast aluminium LM6 housing. Luminaire should have dedicated street light optics for better uniformity & spacing. Luminarie should have air vents in housing for proper thermal management. Min IP preventation should be IP65. System power consumption (including driver losser) should not exceed 20W.Make:LSTS-30-CDL of CG and euivalent Havells/Bajaj/Jaquar/wipro
S& F security light bracket made out of GI pipe 25mm light grade ISI marked 1.5 Mtr long bend to shape as required for LED fittings at site including M S Clamp 2 Nos made out of flat iron 50 X 5mm with necessary nuts Bolts and two coats of alluminium paint over a coat of red oxide primer all as directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for trenches of pipe line in soft/loose soil all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in soft/loose soil etc complete as specified and directed
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point.
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed.Punning thikness shall be measured &paid.
Supply & Laying precast factory made PCC cable concrete cable cover LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete ISI marked
S&F GI Pipe light grade 50 mm for road crossing/ on pole/ on wall for protection of LT Cable.
Supply & Laying cable of 25 Sqmm x 3.5 core, only in trenches / poles / walls XLPE insulated,PVC sheated armoured, Heavy duty electric power cable with aluminium conductor 1100 volts grade with lugs including cable glands complete all as specified and directed by Engineer-in-Charge.
SURAJ ENTERPRISE
badri glass and construction
Rameshwar Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .