Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance AT PO RAJRAPPA PROJECT DIST RAMGARH JHARKHAND 829150 | RAMGARH | RAMGARH | JHARKHAND | 829150 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance MAIN ROAD CHHATARPUR RAMGARH JHARKHAND | RAMGARH | RAMGARH | JHARKHAND | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance AT PO CHITARPUR RAMGARH JHARKHAND | CHITARPUR | RAMGARH | JHARKHAND | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹3.7 L
EMD Value
₹4,700
Closing Date
18 Dec 2023, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO W
SO W OFFICE
Removing dismantling the old existing damage wiring and doing new wiring and providing lighting accessories in all the rooms and sheds of Regional store of Rajrappa Washery
2023_CCL_295601_1
GM(R)/SO(W)/Rjp/23-24/Et/103 dt 08.12.23
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,700
19 Dec 2023
8 Dec 2023
19 Dec 2023
9 Dec 2023
18 Dec 2023
9 Dec 2023
9 Dec 2023 - 12 Dec 2023
Amount
Wiring for light/fan/exhaust fan/call bell point with 1.5sqmm FR PVC insulated Cu conductor single core cable in surface/ recessed PVC condict with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required.
Group A
Group B
Group C
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated Cu conductor, single core cable in surface/recessed medium class PVC conduict as required.
2 x 2.5 sqmm +1 x2.5 sqmm earth wire
2 x 4 sqmm +1 x 4 sqmm earth wire
Supplying and fixing following piano type switch / socket on existing switch box / cover including connections, etc as required.
5 /6 amp switch
5 / 6 Amp socket outlet
15 / 16 Amp switch
15 / 16 Amp socket outlet
Supplying of square batten (tube light) 20 W
Installation, testing and commissioning of pre wired fluorescent fitting/ compact fluoroscent fitting of all types complete with all accessories and tubes etc directly on ceiling/ wall including connections with 1.5 sqmm FRLS PVC insulated copper conductor single core cable for loop and earthing as required.
Supplying and fixing 3 pin, 5 Amp ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections, but excluding modular plate,etc as required.
Supplying and fixing 5A to 32A rating, 240/415V, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) double pole
Supply and fixing following rating double pole(single phase and neutral) 240 volts residual current circuit breaker (RCCB) having sensitivity current 30 miliamperes in the existing MCB DB complete with connections , testing and commissioning etc as required (a) 63 amperes
Supply and fixing following rating 4 pole (single phase and neutral) 415 volts residual current circuit breaker (RCCB) having sensitivity current 30 miliamperes in the existing MCB DB complete with connections , testing and commissioning etc as required (a) 63 amperes
Supply and fixing following way single pole and neutral ,sheet steel MCB distribution board ,240 Volt on surface /recess compltete with tinned copper bus bar ,neutral bus bar ,earth bar ,din bar ,interconnection ,powder painted including earthing etc. as required (but with out MCB/RCCB/Isolator)
8 way double door
4 way (4+12) double door
Supplying and fixing following size/modules, GI Box alongwith modular base and cover plate for modular switchesin recess etc as required 3 module (100mm*75 mm)
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc s required (a) 75 mm * 75 mm * 60 mm deep
LED LAMP 12 W
Total impact of GST for the purpose of CTC
Coalfield Construction
M/s. Balajee Construction
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .