Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.4 L+₹1.6 L (8.89%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical SREEDHAREEYAM PAPPALA KILIMANOOR 695601 | KILIMANOOR | THIRUVANANTHAPURAM | KERALA | 695601 | - | Rejected-Technical L3 | |
| 4 | Rejected-Technical KALLIYOOR P O THIRUVANANTHAPURAM 42 | 42 | - | Rejected-Technical L6 | |
| 5 | Rejected-Technical ALANKARATHIL KALLAMBALAM PO THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | - | Rejected-Technical L4 |
Tender Value
₹22.3 L
EMD Value
₹50,000
Closing Date
23 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, LSGD Dn, thiruvananthapuram DP, Pattom
O/o EE, LSGD Division, thiruvananthapuram DP, Pattom, Pincode - 695004
Please refer tender documents
2020_LSGD_384897_24
e-11/LAC-ADS/EELSGDTVM/2020-21
Open Tender
Civil Works - Roads
Item Rate
180 days
Karavaram GP
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
Yes
online
₹50,000
Yes
8 Nov 2020
14 Sept 2020
25 Sept 2020
14 Sept 2020
23 Sept 2020
14 Sept 2020
60 days
Amount
ROAD CONCRETING.
3.5.1 : Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
3.14 : Construction of Subgrade and Earthen Shoulders<br> Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
od778827/2020_2021 : Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade.
od778830/2020_2021 : Construction of plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 30 (grade),coarse and fine aggregates conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork(steel channel, laying and fixing of 125 micron thick polythene film, wedges,steel plates including levelling the formwork as per drawing),spreading the concrete with showels,rakes,compacted using needle vibrator and finished in continuous operation including provision of contraction and expansion , construction joints, curing of concrete slabs for 14 days,using curing compound(where specified) and water finishing to lines and grade as per drawing and Technical Specifications clause 1501.
SIDE PROTECTION
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
od778828/2020_2021 : Supplying and fixing information board 75x60cm size using GI pipe as post and 1mm MS sheet surrounded by MS angles including Painting, Lettering and fixing in Concrete etc. complete.
od778829/2020_2021 : S/F Name board of size 75*60 cm . Installed in the Appropriate place visible to public made of Brick wall with Granite plaque should be inserted and Engraving Letters etc .complete as per the direction of deptl officers at site .
B UDAYAKUMAR
laldinga
sunilkumar s
Surendran B
Neelambaran.K
Bidder Name
Surendran B
sunilkumar s
laldinga
B UDAYAKUMAR
Chinduprasad
Neelambaran.K
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_546631.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .