DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
Renovation to Sump Panel & Compound Light at Govt. Engineering College, Sector-28, Gandhinagar.
296935
01/09 OF 2026/2027
Open
Electrical
Gandhinagar
7 documents required · 7 mandatory
₹900
DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
₹9,200
15 Apr 2026
15 Apr 2026
15 Apr 2026
28 Apr 2026
15 Apr 2026
Name of Work Renovation to Sump Panel & Compound Light at Govt. Engineering College, Sector-28, Gandhinagar.
Fund Head : Deposited Work
Sr. No. Item No. Particulars. Qty. Rate Amount
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Name Of Work :- Renovation to Sump Panel & Compound Light at Govt. Engineering College, Sector-28,
Item Estimated Rate in Rs.
Item Description Unit Amount in Rs.
No. Quantity in Figure In Word
Replacing old and u/s by Supplying and erecting Flexible
PVC insulated multi strand multi core 1.1 kv grade ISI Rupees Forty Six
1 150 mtrs marked copper wires of following size to be erected as 46.46 And Paise Forty mtr
directed. Six Only
(e) 1.50 Sq.mm 3 core round PVC sheathed
(k) 4.00Sq.mm 4 core round PVC sheathed
150 mtrs 176.75 Seventy Six And mtr
Providing and erecting Mains with ISI marked, 1.5KV
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms to
IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears,
motor starters & control wiring) with required size of
copper lugs, nuts and bolts if required.
(f) One wire 10.00 sq. mm
47 mtrs 91.91 One And Paise mtr
Ninety One Only
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall Rupees Twenty
or ceiling erected with necessary PVC fittings & Junction Four And Paise
3 255 mtrs 24.24 mtr
boxes fixed with adhesive solution & Clamps with following Twenty Four
dia of pipes, in approved manner as directed (a)20 mm Only
Replacing old and u/s by Supplying and erecting LED
street light / Flood light fittings with High power White
LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium
with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
4 4 nos 3,345.12 Hundred Forty Each
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges
shown.) (A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply with
over-voltage protection. (i) above 36 to 48 watts Cat-lll
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
5 40 nos 7,266.95 Hundred Sixty Each
lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
Ninety Five Only
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (B) Flood
Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage
protection. (iv) above 90 to 120 watts Cat-lll
Replacing old Burntout 63A Metal Clad Switch by New
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 25 Rupees Six
KA. at 415 V,having normal current rating up to 25 A to Thousand One
100A. with Fixed thermal & magnetic release suitable to Hundred
6 5 nos 6,173.12 Each
work on A.C. supply 50 c/s. with all internal connections, Seventy Three
spreader tinned copper & complete erected in existing 16 And Paise
G.M.S. housing. ICS=100% of ICU only Twelve Only
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of
KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to
work on A.C. supply 50 c/s. with all internal connections, Rupees Six
spreader tinned copper & complete erected in existing 16 Thousand Seven
7 1 nos G.M.S. housing. ICS=100% of ICU only 6,790.43 Hundred Ninety Each
Cat III And Paise Forty
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB Three Only
for Item No 3-4-1 to 3-4-12 (The Enclosures should be
used of same company of MCCBs to be used)
Replacing old Burntout 125A Metal Clad Switch by New
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of
KA. at 415 V. having normal current rating 125A. with
8 1 nos Fixed thermal & magnetic release suitable to work on 8,055.76 Each
A.C.supply 50 c/s. with all internal connections, spreader
Seventy Six Only
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only
Replacing old Burntout 200A Metal Clad Switch by New
Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of
KA. and above at 415 V . having normal current rating
250A. with variable thermal & magnetic release suitable to
9 1 nos 20,946.39 Hundred Forty Each
work on A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing
Thirty Nine Only
G.M.S. housing. ICS=100% of
ICU only Cat III
Providing and erecting Approved make Earth fault Relay
suitable to mount with inter connection suitable to
following size of moulded case circuit breaker having CT
10 4 nos ratio & MCCB rating as following along with shunt trip 4,687.41 Each
220V AC. with all internal connections & complete erected
Paise Forty One
in existing M.S.housing.. (1) 15 A -100 A , CT Ratio 1/100
1 nos 5,415.62 Hundred Fifteen Each
And Paise Sixty
Supplying & erecting approved make Four Pole 415V
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for
11 3 nos 7,790.13 Hundred Ninety Each
(C)100-125A Cat. III
Supplying and erecting triple pole & neutral 440V / 500V
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
12 3.5 Rn. Mtr. 1,961.42 Hundred Sixty Rn. Mtr.
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each
bar, erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity
(C) Suitable for 300 Amp. capacity Rupees Four
1 Rn. Mtr. 4,909.61 Hundred Nine Rn. Mtr.
And Paise Sixty
Replacing old and u/s by providing and erecting Miniature
circuit breaker single pole 6A to 25A suitable to operate Rupees One
on 240 V A.C. system and having breaking capacity 10 Hundred Twelve
13 10 nos 112.11 Each
KA to be erected in existing box. confirming to IS And Paise
8828/1996 with ISI Mark Cat.III Eleven Only
Replacing old and u/s by Providing & erecting 240 V MCB Rupees Three
double pole switch for motor & inductive load (C Curve) Hundred Thirty
14 5 nos having 10 KA breaking capacity & confirms to IS : 8828 in 330.27 And Paise Each
existing box having following capacity (B) 40 Amp. Twenty Seven
Providing & erecting 415 V MCB Four Pole for Motor & Rupees Five
Inductive Load (C Curve) having 10KA breaking capacity Hundred Ninety
15 12 nos 595.90 Each
& confirms to IS :8828 in existing box having following Five And Paise
capacity (a) 6 to 32 Amp. Cat III Ninety Only
(c)63 Amp. Cat III
14 nos 737.30 Each
Paise Thirty Only
Replacing old and u/s by Sheets steel powder coated
enclosure suitable for incorporating One/Two nos. MCB.
16 5 nos 176.75 Seventy Six And Each
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
17 12 nos appropriate nos. of MCBs.(The DBs should be used of 355.52 Each
same company of MCB to be used) suitable for (A)
single phase incoming and horizontal single phase
outgoing (a) single door (IP-30) (i)4 way
providing and erecting Approved make RCCBs
conforming to IS: 12640 and having sensitivity of 30 mA
and Short Circuit withstand capacity of 10 KA and suitable
for operation on single phase 240 V,50Hz. having
18 5 nos 2,235.13 Hundred Thirty Each
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component. for
following Max. rating erected as directed (ii) 40Amps. DP
Providing and erecting HOT deep Galvanised iron strip
wire 8 to 16 SWG.
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test Rupees Four
certificate including value of earth resistance of installation Thousand Five
20 6 nos duly stamped and signed by agency and officer Incharge 4,591.46 Hundred Ninety Each
has to ensure the value of earthing resistane mentioned in One And Paise
test Certificate) & having back filling compound of (B) Forty Six Only
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency. (a) For Electrical Installation up
to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Replacing Old Rusted Cup Board By New Providing &
erecting weather proof, dust & vermin proof, floor mounted
front operated outdoor type double door cubical panel
board necessary IP-54 and above protection as per
approval from engineer incharge made from 14 SWG thick
CRC M.S. sheet for outer body & doors, 16 SWG thick
CRC M.S.sheet for internal partitions with necessary
accesories , supporting angles/ flats channel including
cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction
of engineer-in-charge with erection of supplied switch
gears, BUSBARS, suitable size of inter connecting PVC
copper wire / copper-aluminium strips, rubber grommets, Rupees Eleven
rib, bakelite control fuses/MCB for measuring Thousand Four
21 7.980 Sq. Mtr. instruments, earth bus & earth bolts, foundation flange - 11,466.53 Hundred Sixty Sq. Mtr.
bolts-base Plates, sufficient nos. of hinged doors, handles Six And Paise
with locking arrangement and rubber gasket,heavy duty Fifty Three Only
end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be
painted with epoxy powder coating. (The rates excludes
the cost of switchgears, bus bars, inter connecting mains
& Copper Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding base beams) The
panel shall be supplied with following approved
manufacturers with following size. (A) locally fabricated
panel board (i) with 350 mm depth
Providing , erecting , fabricating the M.S. structure as per
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections Rupees Seventy
complete with cutting, welding, grinding & finishing duly Seven And
painted with one coat of red oxide with erection on site as Paise Seventy
per direction of engineer in charge with necessary Seven Only
grouting, cementing, plastering & finishing complete.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be
23 10 mtrs laid on wall with necessary clamps or in existing trench / 540.35 mtr
And Paise Thirty
pipe of following size of cables (F) 3 1/2 core 120 Sq.
mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
cable multistrand / Solid Aluminium conductor for 1.1 KV.
24 120 mtrs to be laid on wall with necessary clamps or in existing 140.39 mtr
And Paise Thirty
trench / pipe of following size of cables (C) 4 core 10 Sq.
Replacing old and u/s by Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
25 180 mtrs conductor for 1.1 KV. to be laid on wall with necessary 153.52 mtr
Three And Paise
clamps or in existing trench / pipe of following size of
cables (A) 4 core 16 Sq. Mm
Making trench in soft soil of suitable width of 90 cm deep
for laying cable or locating the fault all over the run and
26 250 mtrs 55.55 Five And Paise mtr
back filling the same and making the surface as normal
Fifty Five Only
Making trench in Hard Murrum / Tar Road of suitable Rupees Four
width of 90 cm or required depth for laying any size of Hundred Thirty
27 15 mtrs cable or locating the fault all over the run and back filling 432.28 Two And Paise mtr
the same and making the surface as normal ground. Twenty Eight
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply by
28 10 mtrs making up to following size of holes at both ends 492.88 mtr
complete. (A) Up to 100 mm bore dia
Eighty Eight Only
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
29 210 mtrs 62.62 Two And Paise mtr
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable
(A)50 mm outer dia
Replacing old and u/s by Providing and, fixing heavy duty
flange type brass cable gland with rubber ring for PVC Rupees Thirty
30 10 nos insulated armoured cable complete with out going tails, 38.38 Eight And Paise Each
insulating tape etc for following size of cables. (C) 2 to 4 Thirty Eight Only
(D) 2 to 4 core 16 Sq. Mm Rupees Forty
10 nos 47.47 Each
Replacing old and u/s by Solder less crimping type
Aluminium lugs conforming to IS suitable for cable of
Rupees Thirteen
following size evenly crimped with high pressure tool &
31 32 nos 13.13 And Paise Each
connected to switchgear terminals with brass/cadmium
plated nut bolts in an approved manner. (B) 10 Sq.mm
(C) 16/25 Sq.mm. Rupees Fifteen
32 nos 15.15 And Paise Each
(D) 35/50 Sq.mm. Rupees Twenty
8 nos 20.20 And Paise Each
(E) 70 Sq.mm. Rupees Twenty
8 nos 25.25 Each
Disconnecting the cable connection and Providing straight
joint with PVC mould using heat shrink /cast resin type
epoxy compound Insulating material and making the joint
Thousand Eighty
complete using necessary in line connectors, hardener,
32 3 nos 1,083.73 Three And Paise Each
earth continuity connection, spacers etc. and reconnecting
the same & ensure the joint resistance within the limits as
per IS. (A) up to 25 Sq mm Cable
(C) 120 to 300 Sq. mm cable. Rupees Two
2 nos 2,654.28 Each
Replacing Old u/s by new Supplying & erecting IP
grade following size section pillar fabricated from joint less
M.S. Sheet with angle iron legs made from jointless M.S.
Angle with cable clamps to be buried in ground to have
appropriate erection to work uniform until erected with
cement concrete foundation and 45 cm high bricks work
finishing with plaster etc. hinged double door internally
supported on both side, Rupees Three
with internal and outside looking arrangement with look Thousand Five
33 1 nos and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two 3,595.60 Hundred Ninety Each
Nos. one is welded and other with nut and bolt for erecting Five And Paise
Bakelite sheet. Painting the Section Pillar inside and out Sixty Only
side with three tank powder coated paint. section pillar
roof should be without joint with water leakage proof &
tested as per IP 55 test & followed by IS 2147 of 1962 (B)
75 X 60 X 45 cm section pillar fabricated from 16 Gauge
MS Sheet with angle iron legs 45 cm long made from 35 X
35 X 5 mm thick MS angle.
Supplying and erecting HYLAM sheet on existing angle
iron frame.for following thickness (E) 10mm
34 0.7 Sq. Mtr. 1,927.08 Hundred Twenty Sq. Mtr.
Paise Eight Only
Replacing Old u/s by new Supplying & erecting approved
make SMC press moulded composite FRP. loop-in, loop-
out approx. 2mm thick box complete with Bakelite
connector strip 5way(3P+N+E),DIN rail for mounting mob Rupees Eight
& hinged doors as per requirement having locking Hundred Ninety
35 10 nos 898.90 Each
arrangements with mounting clamp with nuts, bolts & Eight And Paise
washers suitable for erection on pole with cable clamps& Ninety Only
earth bolt of following size of box.
(A) 300mm x 200mm x 100mm [deep]
Replacing Old u/s by new Supplying & erecting approved
make Digital time switch having lithium cell 6 years
operative and operate battery backup 1 channel day clock
with 14 memory programme, suitable to operate on 240V
+ 5%, 16A with, floating contacts Minimum switching
36 2 nos setup time 1 minimum & LCD display. Also comprised 3,168.37 Each
Eight And Paise
permanent ON/OFF switching. Programming switches &
housed in fire proof thermoplastic enclosure & transparent
cover erected as required with necessary connection
erected as directed.
Replacing Old u/s by new Supplying & erecting power
contactor ,AC3 duty for time switch complete erected as
per direction Cat III (D) 4 pole 440V 40 Amp.
37 2 nos 2,782.55 Hundred Eighty Each
Fifty Five Only
Supplying and erecting approved make panel mounting Rupees One
type Digital Voltmeter having 3 digits LED display, 0 to Thousand Two
750 AC Volts range erected on existing panel board with Hundred
38 4 nos 1,275.63 Each
all connection, wiring etc .with manufacturers calibration Seventy Five
certificate. And Paise Sixty
Supplying and erecting approved make panel mounting
type Digital Ammeter having 3 digits LED display,
external CT operated, calibrated for 0 to 1000 Amps
39 4 nos 1,558.43 Hundred Fifty Each
suitable to operate on 500 Volt AC , erected on existing
Eight And Paise
panel board with all connection, wiring etc .with
Forty Three Only
manufacturers calibration certificate.
Supplying and erecting Ammeter / Voltmeter selector Rupees Three
switch for 3 phase AC Supply 500 V on existing panel Hundred
40 8 nos board with necessary connections. 317.14 Seventeen And Each
Providing & erecting L.T. Current Transformer with bar Rupees Two
primary 50/5 to 1000/5 ratio 15 VA burden erected in Hundred
existing CRCA box duly secured with insulating materials Seventy Four
41 12 nos 274.72 Each
connected to the meter And Paise
Supplying and erecting approved make suitable panel
indicator LED type lamp, lens cover, complete erected
42 12 nos 43.43 Three And Paise Each
with necessary connections.
Forty Three Only
Replacing Old U/s Bu New Supplying & erecting approved
make 3 phase motor control cubical panel ( Star - Delta)
made from16 G. CRCA sheet duly painted with epoxy
powder painted inside and outside with hinged doors and
locking arrangement, consisting of suitable size of ON-
OFF isolator (AC - 3/23 duty) main fuses, single phasing
preventer cum water level. Guard (Complete unit), Toggle
switch to by pass Single phase preventer cum WLG,
indicating lamps for R- Y- B phases, over load relay,
Automatic water level controller, Ammeter & Voltmeter
43 6 nos 12,993.65 Hundred Ninety Each
each with two way selector switch incoming wires duly
Three And Paise
socket Crimped, Panel to be erected on angle iron frame
Sixty Five Only
grouted on wall as directed. Star Delta & main contactor,
overload relay, thermal / Electronic Star delta cutoff timer,
start - stop push buttons. The isolator overload relay &
contactors of L& T, Siemens or Cuttler Hamer make only.
Panel to be erected on angle iron frame ground on wall.
Replacing Old U/s Bu New Providing and erecting ISI Rupees One
marked PVC insulated PVC Sheathed Flat flexible Hundred Forty
44 360 mtrs 146.45 Mtr
Submersible copper cable approved make of following Six And Paise
Size. (C) 3 Core x 4 Sq. Mm Forty Five Only
Providing Water proof straight Joint in PVC insulated flat
flexible copper cable by using insulating material, water
45 6 nos proofing material, & making the joint complete. (A) Up to 189.88 Each
Eighty Eight Only
RUPEES IN WORDS : Rupees Nine Lakh(s) Fourteen Thousand Eight Hundred Ninety One And Paise Seven Only
I/We am/are willing to carry out the work at(No above rates allowed) ____________% below ___________________________________
__________________percent (Should be written in figures and words) below the tendered rates mentioned above.
Amount of my/our tender works out as under :
Put to Tender Rs. 914,891.07 Put to Tender Rs.
Deduct ______ % below Rs.
(Please strike out whichever is not applicable)
1 I/We hereby declare that I/We have visited the site, fully exquisite myself/ourselves with the local situation regarding materials and other factors
pertaining to the work before submitting this tender.
2 I/we hereby declare that I/We carefully studied the conditions of specifications and other tender documents of this work and agree to execute the
same accordingly.
3 A tender with any overwriting in percentage (should both in word and figures) rejected out right.
4 Insertions and/or corrections in the percentage quoted ( both in word and figures) resulting into increase in the value of the work shall be rejected
outright unless it is authenticated by the office opening the tender at the time of opening of tender.
5 Dismentaling the existing material taken by contractor as mention rates.
Deputy executive Engineer
Signature of Contractor C.P Electrical R & B Sub Dn
Less for the D.M
Name of work:-Renovation to Sump Panel & Compound Light at Govt. Engineering College, Sector-28,
Sr.no Item Qty. Per DM rate Total
1 Cost Of Old & u/s 3X1.5 Round Wire 50 Mtr. 3.96
2 Cost Of Old & u/s 36W St.light Fitting 4 Nos. 127.36
3 Cost Of Old & u/s 90W Floodlight Fitting 20 Nos. 281.00
4 Cost Of Old & u/s 63A Metal Clad Switch 5 Nos. 161.45
5 Cost Of Old & u/s 125A Metal Clad Switch 1 Nos. 287.75
6 Cost Of Old & u/s 200A Metal Clad Switch 1 Nos. 307.25
7 Cost Of Old & u/s MCB SP 10 Nos. 4.90
8 Cost Of Old & u/s MCB DP 5 Nos. 15.70
9 Cost Of Old & u/s MCB DP Enclosure 5 Nos. 8.10
10 Cost Of Old & u/s Cup Board 7.98 Sq. Mtr. 207.68
11 Cost Of Old & u/s 4x16 Sq.mm Al. Cable 40 Mtr. 6.90
12 Cost Of Old & u/s Gland & Lugs 1 Lot. 200.00
13 Cost Of Old & u/s Section Pillar 1 Nos. 220.35
14 Cost Of Old & u/s SMC Box 10 Nos. 54.54
15 Cost Of Old & u/s Timer 2 Nos. 123.76
16 Cost Of Old & u/s Contactor 2 Nos. 109.16
17 Cost Of Old & u/s Starter 6 Nos. 629.25
18 Cost Of Old & u/s 3x4 Sq.mm Flat Cable 50 Nos. 12.69
Dy.Executive Engineer Exe.Engineer
Sign of Contractor Cap.Proj. Elect.sub.Div-21 C.P.Electrical Division
Gandhinagar Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
Notice No. 1 of 2026-27 online.pdf
PQ.pdf
SCHEDULE A B AND DMEngineering COllege (2).pdf
STANDARD BIDDING DOCUMENT.pdf
Download all tender documents and submit your bid