Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.2 L+₹22,465 (1.50%)Rejected-AOC 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹15.5 L+₹51,965 (3.47%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹15.9 L+₹94,421 (6.30%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹16.8 L+₹1.8 L (11.8%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
5 Aug 2022, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2022_MES_537175_1
8681
Open Tender
Civil Works
Item Rate
330 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹40,000
Yes
24 Sept 2022
11 Jul 2022
9 Aug 2022
11 Jul 2022
5 Aug 2022
23 Jul 2022
12 Jul 2022 - 22 Jul 2022
Amount
M & L for wiring for circuit /sub main wiring with earth wire, of size 2x 4.0sqmm + 1 x4.0sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten etc,making good disturbed surfaces of walls/ceiling with CM 1:3 and matching surfaces with existing colour. Note :- Two runs of main wire and one run of earh wire and conduit shall be measured as one length.
M & L for wiring for circuit /sub main wiring with earth wire, of size 2x 6.0sqmm + 1 x6.0 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten etc,making good disturbed surfaces of walls/ceiling with CM 1:3 and matching surfaces with existing colour. Note :- Two runs of main wire and one run of earh wire and conduit shall be measured as one length.
M & L for wiring for circuit /sub main wiring with earth wire, of size 2x 10.0sqmm + 1 x 10.0 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten etc,making good disturbed surfaces of walls/ceiling with CM 1:3 and matching surfaces with existing colour. Note :- Two runs of main wire and one run of earh wire and conduit shall be measured as one length.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used triple pole and neutral 4 way 415 V with rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 12 way 240 V with 200 amps rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 amps rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 4 way 240 V with 200 amps rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site.
Supply and fix CRCA sheet metal enclosures distribution board double door,TPN vertical DB 4 way suitable for fixing of Four pole MCCB as in commer & MCBs SP as out going and duly fitted with Bus bar, neutral link, blanking plates, conforms IS 8623-1 & 3, IEC 61439-1 & 3, IK 09 etc complete.The DB shall be included with one No MCCB, 4 pole, 415/430 Volt, 50 Hz, Ics=100% of Icu, having rupturing capacity 16 kA on 415 V icu of capacity 100 Amps complete all as specified and directed. Encloser & MCCB shall preferably of same make. ( MCB s required for out going shall be measured and paid seperately)
BLANK
S & F incl connecting MCB single pole, having rupturing capacity 10kA, 6 amps to 32 amps as ordered 240 Volts complete all as specified and directed
S & F MCB Single pole and neutral (SPN), having rupturing capacity 10kA, 240 V 20 Amps to 32 amps as ordered complete all as specified and directed
S & F MCB triple pole and neutral (TPN), having rupturing capacity 10kA, 240 V 63 amps as ordered complete all as specified and directed
Dismantling existing earthing and M & L Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel including excavation and earth work in any strata all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Taking down carefully existing unserviceable copper/aluminium point wiring (light, fan, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), removing materials for taking credit and making good disturbed surface of wall, floors, etc complete all as directed by Eng-in-Charge.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FR) and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC Conduit 20 mm dia and all accessories Concealed in walls / roofs / floors / ceiling etc.including necessary cutting chases and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: -
(a) One light / ceiling fan / exhaust fan / call bell point controlled by one switch
(b) One 3 pin socket outlet 5 Amps independent board.
(c) One 3 pin socket outlet 5 Amps on the same board with other switch.
All as per item No.15 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 1.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket.
All as per item No 15 here-in-before but for one light point controlled by two 2 way switches , with cable 1.5 sqmm.
M & L for point wiring with 1.5 sqmm PVC insulated (FR) multistranded fiexible unsheathed copper conductor drawn in and including 1.2mm thick PVC casing capping inclusive of one PVC insulated stranded copper conductor of size 1.5 sqmm as earth continuity conductor and terminated in common earth dolly incl provn of pressed steel boxes (fixed flush to wall) for mounting switches, sockets, regulator etc along with 2.8mm thick bakelite sheet duly making opening for fixtures for the following points:-
One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 6 Amp socket outlet point independent
All as per item No 18 here-in-before but one 3 pin socket out let 6 Amps on same board with other switches, with cable 1.5 sqmm.
All as per item No 18 here-in-before but for one light point controlled by two 2 way switches , with cable 1.5 sqmm.
All as per item No.18 here-inbefore but with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 1.5 sqmm PVC insulated flexible copper conductor as in continious earth for one independent 6 pin 16 Amp socket.
S & F switch piano flush type SP one way 6 Amp.
S & F switch piano flush type 2 way 6 Amp.
S & F for switch socket combination 2 in 1, 3 pin, 6 and 16 amp flush type universal.
M & L for switch Socket combination outlet 2 in 1 , 5 pin, 6 Amps flush type.
M & L for Socket outlet 2 in 1 , 3 pin, 6 Amps flush type.
S & F lamp holder, PVC/ Polycarbonate type with back plate for batten angle fitting including 9 watt LED lamp retrofit complete all as specified and directed
S & F Bell Push, flush type, 6 Amps complete all as specified and directed
S & F Ding Dong call bell AC, 230 Volt, single Pole complete all as specified and directed
S & F electronic fan regulator 230 volts flush mounted 200/300 watt stepped type complete all as specified and directed
S & F ceiling rose surface polycarbonate body three terminal complete all as specified and directed
Taking down old existing fitting any type and S & F LED batten tube light fitting of capacity 18 Watt, 4' long a indoor decorative LED engineering plastic batten with opal diffuser, IP20 protection complete all as specified and directed.
Taking down old existing fitting any type and S & F of LED batten tube light fitting of capacity 10 Watt, 2' long a indoor decorative LED engineering plastic batten with opal diffuser, IP20 protection complete all as specified and directed.
Taking down old existing fitting any type and S & F of recess / surface mounting LED flat panel 2'X2' made of sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffiuser, IP20 of capacity 36 watt complete all as specified and directed.
Taking down old existing fitting any type and Supply, fixing and Connecting of LED building security light fitting in top opening LED, highly efficient LED light made of pressure die cast aluminium housing with low power LED's, direct modular IP lens, IP66 complete of capacity 20 wattage complete all as specified and directed
Taking down old existing fitting any type and S & F of energy efficient wall mounted LED bulk head luminaire made of engineering plastic with opal diffuser, IP 65 of capacity 10 watt complete all as specified and directed.
Taking out damaged sunken box from its position by cutting Brick wall and supply and fixing of new pressed steel (galvanised ) sunken box of following sizes including 2.8 mm thick bakelite sheet cover for housing switch/sockets/regulator etc duly cutting grooves, making good disturbed surfaces of wall with CM 1:3 and finaly finishing the wall with colour wash as per existing tint complete all as specified and directed Note:- All fixtures such as switches,sockets,regulator etc shall be measured and paid seperately.
Sunken box of size 100mm x 100mm x 60mm.
Sunken box of size 150mm x 150 mm x 60mm.
Sunken box of size 175mm x 100 mm x 60mm.
Sunken box of size 200mm x 150 mm x 60mm.
Sunken box of size 200mm x 250 mm x 60mm.
Taking down old existing any type of lamp & Supply and fix of 7W LED lamp suitable for B22 capacity all as specified and directed.
Taking down old existing any type of lamp & Supply and fix of 9W LED lamp suitable for B22 capacity all as specified and directed.
Taking down old existing any type of capacitor & supply and fixing of Capacitor electronic type suitable for ceiling fan complete 2.5 mfd capacity all as specified and directed .
Taking down old existing any type of capacitor & supply and fix of Capacitor electronic type suitable for ceiling fan complete 3.15 / 4 mfd capacity all as specified and directed .
S & F for 18 W LED Tube rod on replacing existing 36/40 watt tube rod, electronic ballast as per site requirement , 230V 50 Hz. The LED tube light conforms to applicatble IS 10322/EN 60598, Complete all as specified and directed.
M & L, for opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200mm/1400 sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5mfd and making connection with fan capacitor and connector block, transoporting back after repair, assembling the blades, painting and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. Note : Quoted rate deems to inclusive of labour charges and material/jobs of fan rewinding, capacitor, fan bearing, servicing, painting, wire and transporatation charges.
M & L for opening covers of Exhaust fan 225/250/300mm, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armature coil with complete shaft, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan and making connections, transoporting back after repair, assembling the blades, painting and fixing the E/ fan in its own position with existing clamp with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. Note : 1. Quoted rate deems to inclusive of labour charges and materials/jobs of fan rewinding, fan bearing, servicing, painting, wire and transporatation charges.
M & L for opening covers of air circulating fan / wall mounting cabin fan 400mm/600mm, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armature coil with complete shaft, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan and making connections, transoporting back after repair, assembling the blades, painting and fixing the E/ fan in its own position with existing clamp with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. Note : 1. Quoted rate deems to inclusive of labour charges and materials/jobs of fan rewinding, fan bearing, servicing, painting,wire and transporatation charges.
Supply & fix of exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 250mm including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed. Note : Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard
Supply & fix of exhaust fan steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed. Note : Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard
Supply & fix of ceiling fan complete with blades, down rod from existing roof / trus to fall ceiling, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed. Note : Old ceiling fans shall be deposited to AGE E/M store yard
Taking down and refixing storage type water heater (geyser) of following capacity (any type & Make) from wall by disconnecting the electric connection and water inlet/outlet connection from supply end checking the serviceability of all parts such as inner vessel ,rubber gasket non return valve , heating element , thermostat etc. and refixing the same after replacing unserviceable parts and reassembling complete:-. Note :- Spare parts required to be replaced against unserviceable parts shall be measured & paid separately as supply only
25/35 Litres capactity
50 litres capacity
Supply only heating elements, 1.5 KW 230 volts of existing type & make (Round/triangular) complete.
Supply only heating elements, 2 KW of existing type (Round/triangular)complete.
Supply only thermostat of existing type & make 230/250 volts AC ISI marked complete .
Supply only safety valve as per existing make and type, ISI marked complete
Supply only PVC flexible conneciton pipe with two brass check nuts & two plastic washers complete.
Supply only indicator lamp assembly LED type RED/GREEN for geyser complete
Supply & fix for replacement of metal clad box with plug and socket 20 Amps with one MCB SPN of 20 Amps complete all as specified and directed
Supply and fixing for replacement of Modular type switch 1 way 6A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as all as specified and directed
Supply and fixing for replacement of Modular type switch 1 way 20A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as all as specified and directed
Supply and fixing for replacement of Modular type socket outlet multipurpose having provision for 3 pin 16A and 3 pin 6A, 2 module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as specified and directed
Supply and fixing for replacement of Modular type Fan step regulator electronic type, 230V,120W - 2 module ISI marked with suitable CML No and connecting upto complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 1 module complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 2 module complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 3 module complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 4 module complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 6 module complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 8 module complete all as specified and directed
Supply & Fix for replacement of modular White cover plate with frame, 12 module complete all as specified and directed
Supply & Fix for replacement of modular Metal flush box 1/2 module complete all as specified and directed
Supply & Fix for replacement of modular Metal flush box 3 module complete all as specified and directed
Supply & Fix for replacement of modular Metal flush box 4 module complete all as specified and directed
Supply & Fix for replacement of modular Metal flush box 6 module complete all as specified and directed
Supply & Fix for replacement of modular Metal flush box 8 module complete all as specified and directed
Supply & Fix for replacement of modular Metal flush box 12 module complete all as specified and directed
S & F of electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and directed Note : 1) Old water heater shall be deposited to AGE E/M store yard
Supply & Fix for replacement of MCCB 3 / 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA, make & model as per site requirement complete all as specified and directed
Supply & Fix for replacement of MCCB 3 / 4 Pole, 415 V, fixed type, 200 Amps with breaking capacity 16 KA make & model as per site requirement complete all as specified and directed
Chanda Construction Co.
Shiv Projects
Badri Electricals
Shiv Kripa Tradimg
Harsh Infrastructure
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .