AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103 PH 01902255014
SPECIAL REPAIR TO BLDG NO. T-50 AT TRANSIT CAMP UNDER AGE I R AND D MANALI
2022_MES_556043_2
AGE(I)/MNL-57/2022-23
Open Tender
Civil Works
Item Rate
240 days
palchan
As per NIT and Tender Documents
5 documents required · 5 mandatory
₹500
AGE I R AND D MANALI
₹27,740
Yes
17 Feb 2023
2 Dec 2022
28 Dec 2022
2 Dec 2022
26 Dec 2022
8 Dec 2022
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
S&F mild steel in Joist, channel, angle, or tee sections, Hollow or round steel tubes, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe 410 -W (GdeE- 250) quality-A, complete all as specified and directed by Engineer-in-charge.
S & F mild steel Windows Chajja / wind ties for roof covering including screwing bolts, etc complete all as specified and directed by Engineer-in-charge.
S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying 2 coats of Synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-charge.
Dismantling of wall/ceilng boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets, complete all as specified and directed by Engineer-in-charge.
S&F Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in subbase of floor complete all as specified and directed by Engineer-in-charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and incl 20mm thick screed bed or bedding layer of cement mortar 1:6, all as specified and directed by Engr -in- Charge.
M&L for 50mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection , all as specified and directed by Engr -in-Charge.
M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws frame work as in wall panelling complete all as specified and as directed by Engr-in-charge.
M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws frame work as in ceiling complete all as specified and as directed by Engr-in-charge.
M&L for Plain fillets,square,rectangular or triangular in section, clean sawn, secured with nails or brads of size exc 3sq cm and n exc 6 sq cm of second class softwood complete all as specified and directed by Engineer-in-charge.
M&L for Second class softwood timber framed and fixed, Clean sawn in scantling, complete all as specified and directed by Engineer-in-charge.
S&F in repairs 4.0mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5sq.m in each pane including hacking out from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed by Engineer-in-charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-charge.
M&L for Pre-cast cement concrete block 1:3:6 type C1 (using 20mm graded aggregate) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed by Engineer-in-charge.
M&L for Rendering 15mm thick on brickwork or concrete surfaces or surface other than fair face of brickwork in CM (1:4) finished even & smooth (without using extra cement) complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surface of wall and applying two coats of cement base paint, white or tinted complete all as specified and directed by engr-in-charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc. 1.5 Sqm and n. exc 4 Sqm each.complete all as specified and directed by Engineer-in-charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) not exc. 1.5 Sqm complete all as specified and directed by Engineer-in-charge.
Supply and fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-charge.
S & F, pressed steel door frames with one or more rebates including necessary fixing lungs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed by Engineer - in - Charge .
S & F, Flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides as per SSR Part – I all as specified.
S & F Mild Steel butt hinges, medium weight cold rolled 100mm size all as specified and directed by Engineer - in - Charge .
S & F Extruded aluminium alloy handles, fabricated type, 150mm size all as specified and directed by Engr - in - Charge .
S & F Aluminium anodised, barrel tower bolts of extruded section and fixed length of bolt 150mm long, all as specified and directed by Engineer - in – Charge
S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified and directed by Engineer - in - Charge .
M&L for preparing new wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-charge.
M&L preparing old steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-charge.
S&F, Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engineer-in-charge.
M&L for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, all as specified and directed by engineer-in-charge.
S&F for 25mm dia MS curtain rod with PVC coating (decorative type) fixed with MS hooks incl side brackets (both side) complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M & L for point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core stranded copper conductor for one light/fan and including metallic rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) MAKE:Plaza, finolex,polycab,havells,gloster.
All as per Sl item No 37 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.MAKE:Plazafinolex,polycab,havells,gloster.
All as per Sl item No 37 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.MAKE:Plaza, finolex,polycab,havells,gloster.
All as per Sl item No 37 above herein before but one socket out let 3 pin 15 Amp Independent with 2.5 sqmm wire including 1.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete all as specified and directed.MAKE:Plaza, finolex,polycab,havells,gloster.
S& F, switch piano 1 way, 6 Amps, complete all as specified.
S & F ,switch 1 way, 16 Amps complete all as specified.
S & F, socket piano 5 pin 6 Amps complete all as specified.
S & F ,socket piano 5 pin 6/16 Amps, combination type complete all as specified.
S&F, ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed.Make:Plaza,Havells,SSK.
S & F, Lamp holder incl flexible wire 0.5 Sqmm copper cable all as specified & directed. Make:Havells,Plaza
Supply and fix ,tube light fitting LED type retrofit T-8,20 watt,4 ft long incl LED tube rod and incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed.
S&F, MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 12 ways with IP42 protection complete all as specefied and directed.
S&F, MCB TPN,4 Pole,415 volts,40 amp, 16 KA rupturing capacity for fixing in DBs of including proper thimble connections complete all as specefied and directed. Make:Schenider,Seimens,Legrand
S&F MCB, single pole 240 volts 6 to 32 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. Make:- Indo Asian,standard, havells.Make:Schenider,Seimens,Legrand
S & F, LED security light fitting 30-35 watt,complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as pecified and directed.Make:Havells,Philips,C&S
Supply and fix ,LED bulb 12 watt complete all as specified and directed
Supply, laying and testing cable XLPE 16 sqmm 4 core Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft/diseintegrated soil.
Returning ,fillling in trenches,spreading ,levelling,watering and well ramming in layers not exceeding 25cm thick.
Removing excavated material/ surplus soil and depositing where directed at a distence not exceeding 50mtr.at a level not exceeding 1.5 mtr from starting point.
Supply lay/spread in trenches, river sand ,clean ,including spreading ,levelling ,punning for laying /cushioning of cables complete all as specified and as directed by Engineer-in-charge.
Supply lay in trenches fly ash bricks, old size sub class “B” for cable protection. complete all as specified and as directed by Engineer-in-charge.
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed :-50 mm dia
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less 2.25 meters deep below ground level) with top edge of the plate not less than1.5 meter below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 connected to earthing test point including earth pit and CI cover complete all as directed and specified including testing on completion.complete all as specified and as directed by Engineer-in-charge.
NATHU RAM AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .