Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC 47 5 DURGA MANDIR WARD BARADWAR JANJGIR CHAMPA CG 495687 | JANJGIR CHAMPA | CHHATTISGARH | 495687 | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED BID | |
| 2 | L2₹23.2 L+₹2.8 L (13.5%)Rejected-Finance AT PO GOPALPUR DIST SUNDARGARH ODISHA | GOPALPUR | SUNDARGARH | ODISHA | L2 | Rejected-Finance AS PER TCR | |
| 3 | L3₹23.3 L+₹2.8 L (13.7%)Rejected-Finance CAMPUS CHOWK LAMBIBAHAL BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L3 | Rejected-Finance AS PER TCR | |
| 4 | L4₹26.8 L+₹6.4 L (31.1%)Rejected-Finance AT B L 228 BASATI COLONY ROURKELA SUNDARGARH 769041 ODISHA | ROURKELA | SUNDARGARH | ODISHA | 769041 | L4 | Rejected-Finance AS PER TCR |
Tender Value
₹32.0 L
EMD Value
₹40,000
Closing Date
27 Jan 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Electrical Repairing work of welfare building at township Basundhara Area.
2025_MCL_325898_1
MCL/GM/ BA/EM/e-Proc/2024-25/34 Date- 15/01/2025
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
BASUNDHARA AREA
AS PER NIT AND TC
4 documents required · 4 mandatory
₹40,000
7 Mar 2025
16 Jan 2025
28 Jan 2025
16 Jan 2025
27 Jan 2025
17 Jan 2025
16 Jan 2025 - 20 Jan 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(GROUP "B" )
Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 2.5 sq.mm. + 1x 2.5 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (Suitable for the BLDC type fans)
` Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required(5/6 amps switch)
` Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (3 pin 5/6 A socket outlet)
Supplying and fixing suitable size GI box with modular plate and coverin front on surface or inrecess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240V, onsurface/ recess, complete with tinned copper busbar, neutral busbar, earthbar, din bar, inter connections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator (8 way , Double door)
Supplying and fixing following rating,double pole,240V, isolator inthe existing MCB DB complete with connections, testing and commissioning etc. as required..(40 A)
Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C"-series Miniature Circuit Breaker suitable for inductive load of single pole in the existing MCB-DB complete with connections, testing & commissioning etc. as reqd.
Providing and fixing of 12-15 Watt, LED Ceiling light, 230 volts, Round shape, Natural white colour, polycarbonate material, with min. 70lumen/watt, size: min. 6 inch(size will be as suitable for the place of fixing as per direction of EIC), with integrated driver & anti glare diffuser; as per directioon of EIC
Providing and fixing of Decorative wall lamp, 230 Volts, with lamp/ light LED 5-10Watt, material: mild steel, warm golden light, with suitable diffuser, CCT-5000-6000K, suitable for bedroom, enhancing the asthetic look of the room, as per direction of the EIC
Providing and fixing of Decorative Table lamp, 230 volts, height: min. 12inch, with suitable diffuser type robust and elegent shade ,material, with LED light golden colour, Sturdy and Durable, with wooden base, as per direction of EIC
Wireless & Waterproof door bell Kit, Over 1000 feet Range, 5 Levels Volume, with LED Flash, the push button and receiver should be of elegent design, the push button and receiver should be bettery operated, the doorbell kit should be of reputed make, as per direction of the EIC
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
GOURI BIDYUT CONSTRUCTION (BID ID -1121246)
VAISHALI ELECTRICALS (BID ID -1121627)
Shree Radhe Krishna Electrical Works (BID ID -1121752)
techsummary_337810.pdf
PDF • 2.97 MB
finsummary_337810.pdf
PDF • 2.97 MB
LOA34.pdf
PDF • 2.00 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .