Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 11 492 IRIMPANAM TRIPUNITHURA ERNAKULAM KERALA 682309 | ERNAKULAM | KERALA | 682309 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Finance | Not Admitted-Finance Others-Technical Evaluation not qualified |
Tender Value
₹16.3 L
EMD Value
₹32,700
Closing Date
5 Nov 2022, 6:00 pmClosed
Director
NIT Calicut ,673601
Replacing the existing SV lamp street lights pole with New LED street pole at rajpath area providing additional LED street lights pole at various locations at Main campus
2022_NITC_719112_1
ENGG/EMU/AE/153/Rajpathstreets
Open Tender
Electrical Works
Item Rate
30 days
NIT Calicut
please refer tender documents
9 documents required · 9 mandatory
₹590
Director, NITC
₹32,700
Yes
16 Feb 2023
20 Oct 2022
7 Nov 2022
20 Oct 2022
5 Nov 2022
20 Oct 2022
Amount
Supplying and fixing of Hot dipped Galvanised tubular pole made from 3 mm thick sheet of overall length 23 Feet (7 mtr) with decorative arm bracket of 1 m length, ( Lamp inclination at 15° ) (Model is attached with estimate), 48mm dia x 3.25mm thick with standard arm cap. The bottom dia of the pole shall be minimum 139 mm and top 89 mm with inbuilt cable loop in loop out box with flush door and locking facility. The pole shall be with base plate minimum of 200x200x12mm and 4 Nos M20 x 750 mm size of foundation bolt. The pole shall be mounted on suitable size foundation and provided with 6A SP C curve MCB, loop in loop out 3 phase terminals block, required dia DWC pipe in the foundation for taking cable in & out from the pole, 3Cx1.5 sqmm unarmoured PVC insulated round copper cable from loop in loop out box to light fixture etc with all required accessories. (The cost of the civil foundation is not considered in this item. )(T lite- Onleo Steppo OLP-A4D/Equivalent)- Double Arm
Supplying and fixing of Hot dipped Galvanised continously tapered octagonal pole made from 3 mm thick sheet of overall length 6 Metre with decorative arm bracket of 1 m length, ( Lamp inclination at 15° ), 48mm dia x 3.25mm thick with standard arm cap. The bottom dia of the pole shall be minimum 130 mm and top 70 mm with inbuilt cable loop in loop out box with flush door and locking facility. The pole shall be with base plate of 200x200x12mm and 4 Nos M20 x 600 mm size of foundation bolt. The pole shall be mounted on suitable size foundation and provided with 6A SP C curve MCB, loop in loop out 3 phase terminals block, required dia DWC HDPE pipe in the foundation for taking cable in & out from the pole, 3Cx1.5 sqmm unarmoured PVC insulated round copper cable from loop in loop out to light fixture etc with all required accessories. (The cost of the civil foundation is not considered in this item. )- Single Arm
Charges for concreting with 45 x 45 x 100 cm up to ground level and 40 cm above ground level using 8 mm steel reinforcement as per drawing with cement concrete of 1:2:4, after excavation and plastering the sides including a neat cement flushing coat, painting with cement paint etc, as required.
Supply, installation, testing and commissioning of high quality integrated LED street light fitting of 72 W , The housing should be of non-corrosive high pressure die cast aluminium with heat resistant toughened clear glass fixed with SS screws for with standing extreme environments . It should have corrosion resistant powder coating to pass NSS of 500 Hrs with PF > 0.95. Lifetime of 50K hours @ L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The ingress protection should be minimum IP 66 with an IK rating of 07 for LED and control gear compartments. The LED used in the luminaire should be SMD type only of make - CREE LED / LGIT / Lumileds / Equivalent, colour temp-5700K ± 300K with SDCM of <5 and CRI : 70, Lens make- Led link/equivalent, Efficacy = 120 Lm / watt or higher, THD < 20%, Driver with protection against over voltage & short circuit. The luminaire should have a 20 KV/10KA SPD duly bolted in the luminaire. The input AC voltage range 140-310V AC, side entry mounting for 50 to 65 mm OD bracket, maintenance access to driver from the top, The LED Luminaire should be tested and approved by NITC before commissioning, etc as required. (Philips BRP062 LED 84 CW SLC S1 PSU / Equivalent)
Supplying of one number 2C x 6 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed Armoured power cable of 1.1 kV grade etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 2C x 6 / 4C x 16sq.mm in the existing DWC HDPE pipe as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supplying of one number 4 x 16 sq mm Aluminium condutor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 x 16 sq.mm in the existing masonry open duct as required.
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of 4 x 16 Sq.mm, direct in ground, including excavation of trench, sand cushioning, protective covering with country burnt bricks, laid breadth wise and refilling the trench etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4C x 16 sq.mm in the existing GI pipe as required.
Supply and laying of 3 inch 80 NB GI pipe (medium class B) on ground with all accessories like socket, bend, couplers with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., and making good the damages of road with concrete mixture of 1 : 2 : 4 including watering & ramming etc. as required.
Supply and laying of one number of 12 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.
Supply and laying of one number of 8 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.
Supply and providing GI pipe earthing with 2.5 m long 40 mm GI pipe, drilling of 20 nos 12 mm dia holes on GI pipe, providing masonry enclosure with CI/MS cover plate hinged to frame having locking arrangement, providing funnel, with all materials and labour etc. as required.
Supply and providing "Excel" Earthing Compound including mixing with excavated fine soil and water to make it as slurry and filling around the earth plate etc. as required.
Supply and making end termination with brass compression gland and aluminium lugs for 2C x 6 sq mm XLPE insulated and PVC sheathed aluminium conductor Armoured cable of 1.1 kV grade as required.
Supply and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq mm size XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 kV grade as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Charges for removing the existing cable from the trench and conveyance of the materials to the godown without any damage.
Dismantling of street light pole structure embedded in cement concrete foundation etc. as required.
Charges for conveyance of the dismantled street light pole to the godown without any damage.
Fabrication, supplying and fixing of outdoor, cubical type water proof box (70 x 60 x 30 cm) with rain cap at the top, made out of 2mm thick M.S sheet, powder coated in suitable colour over a coat of primer with provision for fixing 8 way Single phase MCB Horizontal type DB with sufficient clearance detachable gland plate at bottom, having single door with lockable knob, providing danger notice board on the front door, fixing using suitable size 'C' channel, including all minor civil works etc, as required.
Supplying and fixing 12 way, single pole and neutral, sheet steel,double door, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 6 - 32 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25A rating, 240 V, 'C' curve miniature circuit breaker suitable for inductive load of double pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25 A rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of high quality integrated LED spot light fitting of 8 W (Warm white) with spiker for installation, tempered glass material for enhancing the durability of the fixture and accurate lens design for proper light effects . The housing should be of non-corrosive high pressure die cast aluminium with polymethyl methacrylate optical cover. Product should be suitable for continuous operation (10-12 Hrs. per day). The ingress protection should be minimum IP 65 with an IK rating of 06 for LED and control gear compartments. Efficacy must be 60 Lm / watt or higher, Driver with protection against over voltage & short circuit. The input AC voltage range 100-240V AC. The Light should be fixed on foundation made by concreting with 15 x 15 x 20 cm up to ground level and 20 cm above ground level using 8 mm steel reinforcement as per drawing with cement concrete of 1:2:4, after excavation and plastering the sides including a neat cement flushing coat, painting with white cement, paint etc, as required. (Philips BGP150 LED520/WW 8W 45D GM / Equivalent)
Supplying and fixing 210 x 155 x 92 mm or nearest size water proof rigid polycarbonate loop in loop out weather proof box (IP 67) with detachable front cover, including supply & fixing 4 way busbar connector with base insulator, fixing on the wall using suitable size metal clamps and giving connections etc, as required.
Supplying and fixing of 20 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supply and drawing 3C x 2.5 sq mm flat submersible cable with bare bunched copper conductor in the existing steel conduit etc, as required.
NATIONAL ENGINEERING COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .