Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | ₹21.5 L | L1 | Accepted-AOC Being the lowest |
| 2 | L2₹22.3 LRejected-AOC | ₹22.3 L | L2 | Rejected-AOC Being the second lowest |
| 3 | L3₹23.1 LRejected-Finance | ₹23.1 L | L3 | Rejected-Finance Being the second lowest |
| Sl No | Description | Qty | Unit | M. NASEEM RASHEED L1 | SHANUS LAL M L2 | G S Engineering Works L3 |
|---|---|---|---|---|---|---|
| 1.00APPENDIX-A | ||||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. ( 2018 D S R , 2.8.1 ) | 2 | m3 | 300 ₹600 | 300 ₹600 | 298 ₹596 |
| 1.02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. ( D S R 2016 - 2.25 ) | 2 | m3 | 250 ₹500 | 250 ₹500 | 259 ₹518 |
| 1.03 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). ( 2018 D S R , 4.1.8. ) | 2 | m3 | 6,800 ₹13,600 | 6,800 ₹13,600 | 6,835 ₹13,670 |
| 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). ( 2018 D S R, 4.1.5 ) | 2 | m3 | 7,300 ₹14,600 | 7,300 ₹14,600 | 7,389 ₹14,778 |
| 1.05 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) ( 2018 D S R, 5.1.2 . ) | 1 | m3 | 9,000 ₹9,000 | 9,000 ₹9,000 | 9,112 ₹9,112 |
| 1.06 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of Grade Fe 500 D or more . ( 2018 D S R , 5.22.6. ) | 110 | Kg | 100 ₹11,000 | 100 ₹11,000 | 96 ₹10,560 |
| 1.07 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. ( 2018 D S R , 5.9.1. ) | 12 | m2 | 700 ₹8,400 | 700 ₹8,400 | 336 ₹4,032 |
| 1.08 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.1. ) | 2.5 | m3 | 6,500 ₹16,250 | 6,500 ₹16,250 | 7,377 ₹18,442.50 |
| 1.09 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.2. ) | 10 | m3 | 6,800 ₹68,000 | 6,800 ₹68,000 | 8,127 ₹81,270 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Oct 2025, 12:00 pmClosed
The Secretary
Kerala Khadi and Village Industries Board, Vanchiyoor, Thiruvananthapuram
Maintennanace of Karumalloor Panchayath Scheduled Tribe Village Industries Co-Operative Society Building at Karumalloor, Aluva in Eranakulam
2025_KKVIB_803929_1
KB.No.6202/2025/Vi/Plan
Open Tender
Civil Works - Buildings
90 days
Karumalloor in Eranakulam District
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Yes
₹50,000
Yes
28 Jan 2026
29 Sept 2025
10 Oct 2025
29 Sept 2025
8 Oct 2025
29 Sept 2025
Amount
APPENDIX-A
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. ( 2018 D S R , 2.8.1 )
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. ( D S R 2016 - 2.25 )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). ( 2018 D S R , 4.1.8. )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). ( 2018 D S R, 4.1.5 )
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) ( 2018 D S R, 5.1.2 . )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of Grade Fe 500 D or more . ( 2018 D S R , 5.22.6. )
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. ( 2018 D S R , 5.9.1. )
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.1. )
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.2. )
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. ( D S R 6.38 )
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) ( D S R 2018, 13.4.1. )
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 course sand). ( D S R 14.1.2. )
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in Charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) ( D S R 2018 , 15.2 . 1 )
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R 2018 , 15.7.4 )
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. ( D S R 2018, 15.56 )
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. ( 2018 D S R , 8.31 )
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. ( DS R 2018, 11.37 )
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( D S R 11.41 .2 )
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm ( D S R 11.48.2. )
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 0.1 mm), with wall thickness 2.0mm (0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm ( D S R 9.117.1 )
Providing and fixing to Door Frame 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). ( D S R 9. 118. 1 )
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ( DSR 2016 17.2.1)
Providing and fixing PTMT bib cock of approved quality and colour 15 mm nominal bore, 122mm long, weighing not less than 99 gms ( D S R 18.54.2 )
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating ( D S R 18.58.2.1. )
Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ( D S R 2016 18.76.1 )
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms ( D S R 17.73.2 )
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge ( OD BUILDINGS 50.17.1.1 )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 ( OD BUILDINGS 50.18.8.2.1 )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2 ( OD BUILDINGS 50.18.8.3.1 )
Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia 10 Kgf/cm2 ( OD BUILDINGS 50.18.9.4.1. )
Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia 6 Kgf/cm2 ( OD BUILDINGS 50.18.9.4.2. )
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall ( OD BUILDINGS 50.18.9.14.1. )
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 ( OD BUILDINGS 50.18.9.7.2 )
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall ( OD BUILDINGS 50.18.9.17.2 )
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 4 Kgf/cm2 - External work - Exposed on wall ( OD BUILDINGS 50.18.9.19.2 )
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x63x63 mm dia Door Tee
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Vent cowl
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550 X 400 mm with a single 15 mm C.P. brass pillar tap. ( D S R 17.7.4. )
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete ( D S R 17.31 )
Supplying and fixing CP Health Faucet superior quality (Jaguar or equivalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. ( OD BUILDINGS 50.17.1.5. )
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ( D S R 18.53.1 ) 15mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore ( D S R 18.52.1 )
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc For pipes 100 to 250 mm diameter ( D S R 2018 , 19.21.1 )
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 610x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 ( D S R 19.30.2.1. )
Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 15 to below 25 flush capacity ( APPROVED OD LSGD 51.19.ST 2 )
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete . ( 2018 D S R , 13.88 )
Providing and applying Plaster of paris Putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. ( D S R 13.26 )
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer ( D S R 13.43.1 )
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. ( 2018 D S R, 13.99.1 )
Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface ( 2018 D S R 13.111.1 )
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes ( D S R 10.16.1 )
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( D S R 12.50 )
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm). ( D S R 12.51.1 )
Engaging Labour for Repair / Maintenance works Beldar ( D S R 0115 )
Engaging Labour for Repair / Maintenance works Fitter ( D S R 0115 )
Supply and Fixing P V C Floor Trap 110 mm with Necessary cutting of Concrete or Masonry and making good the same ( od31116/2022_2023 )
ENGAGING LABOUR FOR REPAIR WORK CARPENTER GRADE 1 od31118/2022_2023
ENGAGING LABOUR FOR REPAIR WORK Plumber / Fitter od31119/2022_2023
Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of thickness 4 mm ( D S R 14.6.1 )
Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres lead Of area 3 sq. metres and below ( D S R 2018 , 15.12.1. )
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M. S. ANGLES 40X40X6 mm for diagonal braces and central cross piece. ( D S R 10.5.2 )
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35 x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. ( D S R 10.31 )
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.( D S R 9.48.2 )
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls, cutting masonry for cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1 : 3 : 6 ( 1 Cement : 3 Course Sand : 6 Graded Stone Aggregate 20 mm nominal size ), Painting two coats of approved wood preservative to sides of Chowkhats and making good the damages to walls and floors as required complete, includingdisposal of the rubbish to the dumping ground within 50 m lead Door chowkhats ( D S R 14.2.1. )
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. ( 2018 D S R , 13.61.1 . )
Providing and fixing Aluminium work for Doors, Windows, Ventilators and Partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.1.3 )
For Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) ( D S R 21.1.2.3 )
Supplying and Fixing 160 mm UPVC Rain Water Gutters of Approved Brand ( Euro Guard or Equivalent ) with Suitable GI Clamps Fixing to the roof with necessary welding , providing necessary Drops ( Corner , End, or Running ) , Center Joint, End Cap Etc for Rain Water Harvesting including all necessary screws for fixing the Gutters all as Directed By the Engineer in Charge
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R 2016 13.52.1 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4 mm thickness ( D S R 21.3.1. )
Providing and fixing 12 mm thick Prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides ( D S R 21.2.2. )
Providing and fixing DISPLAY SHELF , Horizontal Spacing 90 cm and vertical Spacing 45 cm with 40 MM AND 25 MM MS Hollow tubes, channels, plates etc., and 8 mm Glass , including welding, grinding, providing 2 coats of primer and 2 coat of Epoxy Paint ( SPRAY FINISH ) etc complete, including fixing the Shelf to the Wall / Columns with necessary accessories & stainless steel dash fasteners , Providing 8 mm Glass of of required size, including grinding and polishing the exposed edges , all as per the Drawing and approval of the Engineer-in-charge,
Supplying fabricating and fixing in position Sales counter with Granite / Glass top of 60 CM TOP WIDTH AND HEIGHT 80 CM ( AV ) ,made with frame work of 16 mm BWR ( IS 303 GRADE ) Plywood including covering the front and SIde , Providing inside Racks using 16 mm BWR ( IS 303 GRADE ) Ply wood, Covering all the exposed surface using 1.00 mm thickness decorative Laminated sheet with Texture Finish of approved brand with suitable adhesive ( HEATEX or equvqlent ), the inside of the counter being painted with synthetic enamel paint 2 coat over one coat of wood primer and putty leveling, filling etc. Providing 12 mm thic edge polished glass/ 18 mm thick egde polished Granite for the Top area with necessary glass caps or adhesives, providing 8 mm thick edge polished glass for the front vertical area with suitable D brackets , Finishing including polishing all the exposed area complete as per the approved drawings and direction of the Engineer in charge.. ( OBSEVED DATA od3_P100001/2019-2020 )
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: ( D S R 25.7. ) For Name Board
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. GROUP B ( D S R ELECTRICAL 1.10.2 )
Wiring for Twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 2 Way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( D S R ELECTRICAL 2016 1.11 )
SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS ( od15443/2021_2022 )
Supplying and fixing PVC batten/ angle holder including connection etc. as required. ( D S R ELECTRICAL 1. 58 )
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C ( OD ELECTRICAL 90.4.5.2. )
Supply and installation of suitable size MS fan clamp with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. ( OD ELECTRICALS 90.4.2 )
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. ( D S R ELECTRICAL 1.25 )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 MM ( D S R ELECTRICAL 1.21.1 )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 MM ( D S R ELECTRICAL 1.21.2 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm ( D S R ELECTRICAL 1.17.3 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm ( D S R ELECTRICAL 1.17.12 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm ( D S R ELECTRICAL 1.17.21 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) ( D S R ELECTRICAL 1.27.1 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) ( D S R ELECTRICAL 1.27.2 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 6 Module ( 200 mm X 75 mm ) ( D S R ELECTRICAL 1.27.4 )
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) ( D S R ELECTRICAL 1.27.6 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch ( D S R ELECTRICAL 1.24.1 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Two Way 5/6 amps switch ( D S R ELECTRICAL 1.24.2 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch ( D S R ELECTRICAL 1.24.3 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet ( D S R ELECTRICAL 1.24.4 )
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet ( D S R ELECTRICAL 1.24.5 )
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. ( D S R ELECTRICAL 1.26 )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). ( D S R ELECTRICAL 1.31 )
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43) ( OD ELECTRICAL 90.11.1.12 )
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole ( D S R ELECTRICAL 2.10.1 )
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required ( D S R ELECTRICAL 2.11 )
Supplying and fixing following rating, Four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps ( D S R ELECTRICAL 2.13.2 )
Supplying and fixing following rating, Four pole, ( Three phase and neutral), 415 volts, Residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps ( D S R ELECTRICAL 2.15.3. )
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. ( D S R ELECTRICAL 5.1. )
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) ( D S R ELECTRICAL 5.9. )
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. ( D S R ELECTRICAL 5.17 )
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. ( D S R ELECTRICAL 6.12 )
SUPPLY AND FIXING WEATHER PROOF ENCLOSURE FOR FIXING METER BOARD AND ACCESSORIES IN SURFACE OR IN RECESS INCLUDING CUTTING AND MAKING GOOD THE WALL . ( od15456/2021_2022 )
SUPPLY AND FIXING 32 A , 415 V TWO WAY NEUTRAL LINK IN THE METER BOARD AND GIVING CONNECTIONS ( od15440/2021_2022 )
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 4 x 6 sq. mm ( D S R ELECTRICAL 1.17.31 )
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator ( OD 90.10.3.15 )
Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 12 W , square or round, Cool or Warm , size 155 mm ( or nearest available size ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. ( od 33_P100001/2022_2023 )
Supplying installation testing and commissioning of 1 Ton Split Air conditioner ( INVERTOR AC ,FULL COPPER ) with remote control of make Voltas / Blue Star / L.G /.Carrier or equivalent make with 1 unit of Voltage stabilizer ( V Guard Stabiliser or Equivalent approved make suitable for 1 Ton invertor AC ) , providing angle iron / Wall Munting Bracket support to the out door and indoor unit , copper tube, cable etc complete. including cutting and making good of the masonry wall / concrete as directed by the Engineer in Charge .
Supplying installation testing and commissioning of 2 Ton Split Air conditioner ( INVERTOR AC ,FULL COPPER ) with remote control of make Voltas / Blue Star / L.G /.Carrier or equivalent make with 1 unit of Voltage stabilizer ( V Guard VG 500 Stabiliser or Equivalent approved make suitable for 2 Ton invertor AC ) , providing angle iron / Wall Munting Bracket support to the out door and indoor unit , copper tube, cable etc complete. including cutting and making good of the masonry wall / concrete as directed by the Engineer in Charge .
SHANUS LAL M (BID ID -2377606)
G S Engineering Works (BID ID -2378473)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid