| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-Finance 2ND FLOOR SHAHEEN BAGH F 207 ABUL FAZAL ENCLAVE II JAMIA NAGAR OKHLA SOUTH DELHI 110025 | SOUTH EAST | DELHI | 110025 | L1 | Accepted-Finance Selected | |
| 2 | L2₹15.6 L+₹12,313.94 (0.80%)Accepted-Finance BASEMENT B 724 SADARJUNG ENCLAVE NEW DELHI 110029 | SOUTH | DELHI | 110029 | L2 | Accepted-Finance Selected | |
| 3 | L3₹15.6 L+₹14,827 (0.96%)Accepted-Finance H 123 GYAN MANDIR ROAD GALI NO 3 JAITPUR EXTENSION BADARPUR NEW DELHI 110044 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110044 | L3 | Accepted-Finance Selected | |
| 4 | L4₹17.1 L+₹1.7 L (10.8%)Accepted-Finance 50 3 S F ARJUN NAGAR NEW DELHI 110029 | SOUTH | DELHI | 110029 | L4 | Accepted-Finance Selected | |
| 5 | L5₹17.3 L+₹1.9 L (12.3%)Accepted-Finance NONE | L5 | Accepted-Finance Selected |
Tender Value
₹25.1 L
EMD Value
₹50,261
Closing Date
11 Feb 2026, 3:00 pmClosed
The Executive Engineer (E)
The Executive Engineer (E) EMD South East, Thyagraj Stadium, New Delhi-110003
(SH -Upgradation and Renovation of Electrical Wiring, Rewiring and Worn-out Electrical Fittings in the Various Flats in Block No. 1, 2, 3 at GK-1)
2026_PWD_286276_1
133/EE(E)/EMD South East/PWD/2025-26
Open Tender
Miscellaneous Services
Works
90 days
At Site
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹50,261
13 Feb 2026
5 Feb 2026
11 Feb 2026
5 Feb 2026
11 Feb 2026
5 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group B
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
Group B
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq mm
3 x 6 sq. mm
3 x 10 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 A socket outlet
6 pin 15/16 amp socket outlet
Bell Push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 module (75mm x 75mm)
3 Module (100 mmX75 mm)
6 module (200mm x 75mm)
8 Module (125 mmX125 mm)
12 Module (200m x 150mm)
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single Pole
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply, Installation, Testing and Commissioning of 1200mm ceiling fan class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supplying, installation, testing and commissioning of 6 Pole heavy duty 300 mm sweep 900 rpm metallic body Exhaust Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required.
Supplying, installation, testing and commissioning of 150 mm sweeep plastic body Fresh Air Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required.
Supplying, installation, testing and commissioning of 200 mm sweeep plastic body Fresh Air Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required.
Supplying ,installation & testing & commissioning of 10W 2ft. LED Mirror Light (6500K) luminarie having integrated LED Driver with high transitivity opal diffuser for direct lighting i/c wiring and making connections with 1.5sq.mm. PVC insulated FRLS, copper conductor single core cable including loop earthing suitable for operation on 230 volt 50 Hz AC supply complete with all accessories/attachments etc. as reqd.
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
Supplying, installation & testing & commissioning of decorative wall mounting fixture with Opal Glass diffuser suitable for 9-20 W LED Lamp i/c wiring and making connections with 1.5sq.mm. PVC insulated FRLS, copper conductor single core cable including loop earthing complete etc. as required, suitable for 230 volt 50 Hz AC supply complete with all accessories/attachments etc. as reqd.
Supplying and fixing 63 A rating double pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 63 A rating double pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 9-12 W LED Bollard fitting made with extruded aluminium profiles die cast aluminium base / components, U.V. resistance diamond shape polycarbonate diffuser, primer coated and painted with polyurethane paint having IP66 protection and 800 mm to 900 mm overall length suitable for single phase 230V, 50Hz electric supply complete with testing and commissioning etc. as required.
Providing and fixing of Hot Press Sheet Molding Compound (Fiber) sheet (thickness-3 mm) to cover upto 2.5 mtr. height around electric Pole from the bottom of pole and permanent fixed it in round shape on the existing electric light pole with the help of Epoxy Resin Molding Compound and raw fiber at site to protection from electric shock and having arrangement of hanging of round cover sheet upto window of pole with the help of 2 nos. nuts support for maintenance purpose i/c painting of Red/Black/Steel Gray colour on protection round cover sheet on the existing poles as per direction of Engineer-in-Charge. (NOTE: Sample must approve before installation at Site).
Providing and laying in position specified grade of reinforced cement concrete ,excluding the cost of centering ,shuttering ,finishing and reinforcement -All work upto plinth level. (a) 1:2:4 (1 cement:2 coarse sand(zone-III) derived from natural sources:4 graded stone aggregate 20mm nominal size derieved from natural sources.)
Dismantling manually /by mechanical means including stacking of serviceable matrial and disposal of unserviceable material within 50 meters lead as per direction of Engineer -in-charge: Bituminous road
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Credit for dismantle materials
Assorted Ceiling Fans
Assorted Fresh air Fan
Assorted Exhaust fans
Assorted Switch /sockets/Regulators/Sheet
Assorted all type indoor fittings
Assorted MCB
Assorted MCB DB
Assorted wire with insulation copper
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
tender.pdf
Tender Documents • 2.50 MB
BOQ_378937.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .