Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L1 | Accepted-AOC lowest | |
| 2 | L2₹9.5 L+₹78,520 (8.96%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹9.6 L+₹84,365 (9.63%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
3 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
REPAIRS TO ALL TYPES OF FANS DESERT COOLARS WATER COOLARS AIRCONDITIONERS AND REFRIGIRATORS AT MIL STN SAMBA
2020_MES_350100_1
GE/SMB/T-02/2020-21
Open Tender
Civil Works
Item Rate
180 days
SAMBA
CLASS E CAT b i
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹20,000
Yes
13 Jul 2020
5 Jun 2020
6 Jul 2020
5 Jun 2020
3 Jul 2020
19 Jun 2020
5 Jun 2020 - 8 Jun 2020
60 days
Amount
Taking down carefully 1200/1400mm sweep ceiling fan of any make from the hook and carry to the wksp including rehanging after repair the same at existing position after cleaning dirt,oiling, greasing of fan complete all as specified and directed by Engr-in-Charge . NOTE :- Total service time from taking down to rehanging must not exceed 3 Days. APenalty of Rs 200.00 per fan per day ( or part there of) upto a maximum of Rs 2000.00 shall be imposed in case work not excueted within specified time.
All as per serial item No-1.00 above but for Exhaust fan 225mm to 450mm sweep.
All as per serial item No-1.00 above but for pedestall/wall mounting fan of any type and any description.
M&L for Strip opening of ceiling fan 1200 sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM including replacement of rubber real ,nut bolt,clamp as required and reasembling etc complete all as specified and directed by Engr-in-Charge. Note :- RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
All as per srl item No.4 above but ceiling fan of 1400mm sweep. Note :- RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
All as per serial item No-4.00 above but for wall mounting/pedestal fan of any type and any description.
Material and labour for re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 225mm to 300 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring so as to achieve original specifications i.e current rating and RPM including all insulating materials, bushes etc re-assembling complete all as specified and directed by Engr-in-Charge. Note :-RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
Material and labour for re-winding of exhaust fan/bracket fans/wall mounting fans/pedestal fans 301 to 450 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring so as to achieve original specifications i.e current rating and RPM including all insulating materials, bushes etc re-assembling complete all as specified and directed by Engr-in-Charge. Note :-RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge.
Supply & fixing ball bearings suitable for ceiling fans of size 6201 complete all as specified and directed by Engr-in-Charge complete ,Make:SKF or technocommerically equivalent make of NBC/URB.
All as per srl item no 9 but of size 6202 complete,Make:SKF or technocommerically equivalent make of NBC/URB.
All as per srl item no 9 but of size 6203 complete,Make:SKF or technocommerically equivalent make of NBC/URB.
All as per srl item no 9 but of size 6204 complete,Make:SKF or technocommerically equivalent make of NBC/URB.
Taking out existing worn out /defective gun metal bush and material & labour for new gun-metal bush to the ceiling fans of any size/make incl reassembling and testing etc complete all as specified and directed by Engr-in-Charge.
Taking out existing defective/worn out condenser any size/make and material and labour for condensor of capacity 2.5 mfd ,220 Volts including making connections etc complete all as specified and directed by Engr-in-Charge, Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
All as per srl item No.14 here-in-before but of capacity 3.15 mfd capacity,Make: USHA or technocommerically equivalent of make BAJAJ/HAVELLS.
Taking out defective fan regulator any type and make and supply & fix electronic step type fan regulator 5 stage speed variation ISI marked including making connection etc and cutting to the required size of 3 mm thick bakelite sheet where required complete all as specified and directed, Make :Havells or technocommerically equivalent of make Cona/ Plaza.
M&L for Replacement of old damaged/ un-serviceable metallic blades of ceiling fan with metallic blade of 1200mm/1400mm sweep size, complete all as specified and directed
M&L for Replacement of old warn out bush with new bush as per sample suitable for 1200/1400 mm sweep ceiling fan , complete all as specified and directed
Taking down worn out/defective metalic blades of exhaust fan/wall mounting/padestal fan off size 225mm to 300mm sweep and supply and fixing new blades as per sample and make to the exhaust fan refixing in existing position etc complete all as specified and directed.
Taking down worn out/defective metalic blades of exhaust fan/wall mounting/padestal fan off size 301mm to 450mm sweep and supply and fixing new blades as per sample and make to the exhaust fan refixing in existing position etc complete all as specified and directed.
M&L for Replacement old damaged/ unserviceable connection wire with new flexible, PVC insulated, multi-stranded, copper wire, 0.75 Sqmm, twine core, FRLS, complete all as specified and directed.
Taking out worn out/cracked canopy and supply & fixing canopy with screws to the ceiling fans of any size/make etc complete. (Set of 2 pieces)
M&L for Replacement old damaged/ unserviceable/ rusted nut, bolt with new nut, bolt of 10mm dia and 50mm long, mild steel including spilt mild steel safety pin, complete all as specified and directed
M&L for Replacement old damaged/ unserviceable ceiling fan hanging clamp/ assembly with new hanging clamp/ assembly, mild steel including rubber reel, complete all as specified and directed
Opening up of existing water cooler for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning the tank, and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit(Compressor) with new hermatic sealed unit, for water cooler of 40 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hematic sealed unit, for water cooler of 41 - 80 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hermatic sealed unit, for water cooler of 81-120 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for water cooler of 150 liters capacity, complete all as specified and as directed
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for water cooler of up to 80 liters capacity including testing against any leakage, complete all as specified and as directed
All as per serial item No-30 above but for water cooler of 81 - 120 liters capacity.
All as per serial item No-30 above but for water cooler of 150 liters capacity.
M and L for Replacement of old unserviceable/ damaged starting relay with new starting relay for water cooler of 40, 60 120 and 150 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged over load protection relay with new over load protection relay for water cooler of any capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 40-60mfd, for water cooler, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 60-80mfd for water cooler, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 80-100mfd for water cooler, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged starting condenser with new starting condenser of 100-120mfd for water cooler, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 10mfd, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 25mfd complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged running condenser with new running condenser of water cooler 36mfd complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged thermostat of any size for water cooler complete all as specified and as directed.
M and L for Replacement of fan motor 1/35 HP for water coolers any capacity complete all as specified and directed
M and L for Replacement of fan motor 1/10 HP for water coolers any capacity complete all as specified and directed
M and L for Replacement old damaged/ unserviceable PVC hose pipe with new PVC hose pipe, suitable for water cooler of any type and any capacity, complete all as specified and directed
M and L for Replacement old damaged/ unserviceable push cock with new push cock, chromium plated, for 15mm bore pipe, suitable for water cooler of any type and any capacity, complete all as specified and directed
M and L for Replacement of old unserviceable/ damaged ball valve with new ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed
M and L for Replacement of PVC plug top 6 Amp, 240Volts (ISI marked) complete all as specified and directed make Anchor /SSK /Plaza /Havells
Opening up of existing Refrigerator for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning tinside and outside , and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermetic sealed unit with new hermatic sealed unit of 1/8 HP (Compressor), for refrigerator of 165-175 liters and 180-200 liters capacity, complete all as specified and as directed.
M and L for Replacement of old unserviceable/ damaged hermetic sealed unit with new hermatic sealed unit of 1/6 HP (Compressor), for refrigerator of 210-320 liters capacity, complete all as specified and as directed
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for refrigerator of 165-175 litres capacity including testing against any leakage, complete all as specified and as directed
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for refrigerator of 210-320 litres capacity including testing against any leakage, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged over load protection relay with new over load protection relay, 1/8 HP for refrigerator of 165 to 320 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged starting relay with new starting relay for refrigerator of 1/8 HP and 1/6 HP, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged thermostate with new thermostate for refrigerator of any size and any descriptions, complete all as specified and as directed .
M and L for Replacement of old unserviceable/ damaged freezer door with new freezer door including proper insulation and rubber seal, for refrigerator of 165/175 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged freezer door with new freezer door including proper insulation and rubber seal, for refrigerator of 210/320 liters capacity, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged PCB with new PCB for refrigerator of any capacity and any description, complete all as specified and as directed
M and L for Replacement of old unserviceable evaporator of referigerator of any capacity complete all as specified and directed
M and L for Replacement of old unserviceable condensing coil of referigerator of any capacity complete all as specified and directed
Opening up of existing deep freezer for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning tinside and outside , and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit for deep freezer 120 to 600 liters capacity, complete all as specified and as directed
M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for deep freezer 320 liters capacity including testing against any leakage, complete all as specified and as directed.
Inspection of air conditioner window type 1.5/ 2.0 T cap , at the site and complete servicing as per manufacturers instructions incl , cleaning/ removing the dust and filter, blower, fan motor, washing/ cleaning the outer surface and testing including making necessary connection to the power point and presenting before MES rep to ascertain repair/replacement if any , complete all as specified and as directed by Engineer-In-Charge. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
Inspection of air conditioner spilt type1.5/ 2.0 T cap , at the site and complete servicing as per manufacturers instructions incl , cleaning/ removing the dust and filter, blower, fan motor, washing/ cleaning the outer surface and testing including making necessary connection to the power point and presenting before MES rep to ascertain repair/replacement if any , complete all as specified and as directed by Engineer-In-Charge. Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item
M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for air conditioner window 1.5 T, complete all as specified and as directed
M and L for Replacement/ filling of refrigerant (R-134a), suitable for air conditioner 1.5 T window type and any specifications including testing against any leakage, complete all as specified and as directed
M and L for Replacement/ filling of refrigerant (R-134a), suitable for air conditioner spilt type 2.0 T and any specifications including testing against any leakage, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged condensing coil with new condensing coil for air conditioner of 1.50 Ton capacity, window type complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged blower motor with new blower motor for air conditioner of 1.50 Ton capacity, window type, complete all as specified and as directed
M and L for Replacement of old unserviceable/ damaged PCB with new PCB, for split air conditioner of any capacity and any specifications, complete all as specified and as directed.
Repair to voltage stabilizer of 5 KVA capacity, 240 Volts, single phase including M and L for Replacement of old burnt transformer winding with new copper winding wire of existing specifications for air conditioner of any capacity, complete all as specified and as directed
All as per serial item No-73 above but for voltage stabilizer 4.0 KVA capacity complete all as specified and as directed
All as per serial item No-73 above but for voltage stabilizer 2.0 to 3.0 KVA capacity.complete all as specified and as directed
All as per serial item No-73 above but for voltage stabilizer 0.50 to 1.0 KVA capacity.complete all as specified and as directed
M and L for Replacement old damaged/ unserviceable connection wire with new PVC insulated, multi-stranded, copper wire, 1.50 Sqmm, 3 core, FRLS, complete all as specified and directed
M and L for Replacement old damaged/ unserviceable connection wire with new PVC insulated, multi-stranded, copper wire, 2.50 Sqmm, 3 core, FRLS, complete all as specified and directed
Rewinding for deser water cooler motor with super enameled copper winding wire of same guage and weight including varnishing and heating, inter connection etc complete all as directed ( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged wooden wool pad with new wooden wool pad for three sides, for desert cooler of required specifications, complete all as specified and as directed( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged submersible water pump with new submersible water pump, AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler, complete all as specified and as directed( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged Capacitors, 4.0 mfd, 50Hz, 230 Volts complete all as specified and as directed ( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged fan motor with new fan motor, AC operated, single phase, capacity 1.70 HP, 240 volts suitable for desert cooler and making necessary connection to power supply, complete all as specified and as directed( Cooler of iron body , standard size )
M and L for Replacement of old unserviceable/ damaged front grill with new front grill for desert cooler of any descriptions, complete all as specified and as directed ( Cooler of iron body , standard size )
M/S GUPTA TRADING CO
AGGARWAL ASSOCIATES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .