| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-AOC H NO 670 SECTOR 10 PANCHKULA HRY 134115 | PANCHKULA | HARYANA | 134115 | L1 | Accepted-AOC AOC | |
| 2 | L2₹63.2 L+₹5.3 L (9.22%)Rejected-AOC | L2 | Rejected-AOC rejected | |
| 3 | L3₹64.9 L+₹7.0 L (12.1%)Rejected-AOC 34 RAJA ROAD DEHRADUN UTTARAKHAND 2480001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC rejected | |
| 4 | L4₹65.5 L+₹7.6 L (13.1%)Rejected-AOC 37 2 INDIRA COLONY CHUKHUWALA DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC rejected | |
| 5 | L5₹66.7 L+₹8.8 L (15.2%)Rejected-AOC 67 PATEL NAGAR NEW MANDI MUZAFFARNAGAR INDEX NO C 630 HQ CE WC | L5 | Rejected-AOC rejected |
Tender Value
₹77.2 L
EMD Value
₹1.4 L
Closing Date
12 Oct 2024, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
SPECIAL REPAIR TO BLDG NO P-117 AND P-119 OF TALWAR LINE UNDER GE DEHRADUN
2024_MES_672994_1
9953/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
GE Dehradun
₹1.4 L
Yes
4 Jan 2025
7 Sept 2024
14 Oct 2024
7 Sept 2024
12 Oct 2024
28 Sept 2024
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretebut excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 , using old size bricks, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (using old size bricks) complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth (without using extra cement) complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and smooth (without using extra cement) complete all as specified and directed.
M & L for 10 mm thick rendering on celing surface in cement mortar 1:3 mixed surface finished even and smooth including fixing of wire mesh wherever required complete all as specified and directed.
M&L for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 1-2 mm thick wall care putty finish wall surface even & smooth all as specified and directed.
M&L for two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint over applying of 1-2 mm thick wall care putty finish wall surface even and smooth including preparation of new plaster external surfaces of wall etc with scrap wire brush and washing with water complete all as specified and directed. (Note :- Cost of scaffolding upto 10m height of building is included in this item.
M&L for preparation of newly plastered surface on ceilings and applying three coats of white wash on ceiling, off sets, pillar etc. all as directed and specified.
M&L for complete removal of existing treatment of walls including corners and applying two coats of distemper oil emulsion over applying of 1-2 mm thick wall care putty finish wall surface even & smooth all as specified and directed.
M&L for complete removal of existing treatment of walls including corners and applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over applying of 1-2 mm thick wall care putty finish wall surface even and smooth complete all as specified and directed. (Note :- Cost of scaffolding upto 10m height of building is included in this item.
M&L for complete removal of existing treatment on ceiling and applying three coats of white wash on ceiling, off sets, pillar etc all as directed and specified.
Writing letters or figures (Block. Roman, Italic or Indian) nexc 30 cm high Writing bldg No complete all as specified and directed by Engr-in-Charge.
M & L applying two coats of Synthetic enamel paint on new or old wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
M&L for non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x 6-7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
All as per item No 17 here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4, complete all as directed and specified.
M&L for non skid/mat finish ceramic colour tiles of size 300 mm x 300 mm and 7 to 8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L glazed ceramic colour tiles size 300 mm x 450 mm/ 300 mm x 600mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as directed and specified.
Dismantling of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for 18-20 mm thick Granite, of any type, table rubbed and polished in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified including moulding complete all as specified and directed.
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames exc 1.50 sqm but n.exc 4.00 Sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F factory made 100 % solid wood plastic composite (WPC) door frame 125x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and directed by Engr-in-Charge. Make : ECHON/Sintex/Rajshree
S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified and directed by Engr-in-Charge. Make : ECHON/Sintex/Rajshree
S&F 30 mm thick moulded WPC factory made Glazed and skeleton shutter (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified and directed by Engr-in-Charge. Make : ECHON/Sintex/Rajshree
Supply and fix for Pressed steel door frame of size 105 x 60 mm, double rebated for doors made out of 1.25mm thick mild steel sheet including necessary fixing lugs, hinges lock strike plate etc, complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, designer with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges will be painted to match with prelam sheet, PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 24 to 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded both side prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing complete all as specified and directed.
S&F MS Butt Hinges medium weight, cold rolled mild steel 100 mm fixed to steel/wooden shutters complete all as specified and directed.
S&F for mild steel barrel tower bolts 150 mm size, stove enamelled black, with bright bolt fixed in repairs complete all as specified and directed.
S&F 150 mm size solid in one piece stainless steel handles, cast D type, fixed in stainless steel screws complete all as specified and directed by Engr-in-Charge.
S&F 300 mm long MS Helical door spring welded to steel frame or fixed to wooden door frame with screws including roller and roller plate etc complete all as specified and directed.
S&F floor door stopper of stainless steel double legged and tongue, 304 grade, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed.
S&F stainless steel sliding door bolts 204 grade, hasp and staple type with bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and directed.
S&F in repair aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one nos wire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass frosted glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mm Shutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36 mm Chowkhat bottom size : 50.30x26x1.20mm Chowkhat top & sides size: 50.30x26x1.00mm . Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F powder coated aluminium grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc. aluminium section 15 micron thick anodizing complete all as specified and directed including taking down old grill and removing from site.
S & F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc.complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F steel work in tubular section for stair case, railing at balconies, roof truss etc including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-179 grade St-240 complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of old sheets complete all as specified and directed.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
S&F Stainless steel 304 grade wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and directed.
Dismantling block board/ boarding of any description and in any position complete including iron mongries ,complete all as specified.
Supply & fix 18 mm thick PVC board one side prelaminated and other side plain white colour as in cup board shutters and frames, kitchen cabinet front shutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive complete all as specified and directed by the Engineer-in-Charge.
Supply & fix 18 mm thick PVC board both side plain white colour as in cup board shutters and frames, kitchen cabinet front shutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive complete all as specified and directed by the Engineer-in-Charge.
Supply & fix 6 mm thick PVC board both side plain white colour as in cub board selves etc fixed with screws, salvent cement/ adhessive , complete all as per specifications & directed by Engr-in-Charge.
S & F Continuous (Piano) hinges, mild steel, bright finished or stainless steel 304 grade, width of flaps (When open) 30 mm complete all as specified and directed.
S&F magnet catcher for cub board with brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets, decorative finished at both ends complete all as speccified and directed as per approved sample complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing including dismantling of old tubing complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing including dismantling of old tubing complete all as specified and directed.
Material & labour for demolition of existing sunken portion & taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish off the premises, cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00 Kilogram/Square metre and grouting 25mm thick cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (b) Material & labour for two coat of acrylic cementitious water proofing coating (Dr. FIXIT pidifin 2K manufactured by M/S Piditite Industries Ltd or equivalant) and followed by a overlay protective screed 15mm thick CM(1:3) alongwith liquid water proofing compound approved make on top surfaces of sunken slab after preparation as mentioned above method of application for acrylic cementitious water proofing coating is followed as per manufacturers instructions complete all as specified and as directed by Engr-in-Charge.
S&F in repair vitreous china squatting pan (orissa pattern) long pan size 580x440mm white with integral footrest with cast iron spun 600 mm long 'P' trap (SI 3989 1984), set in cement concrete type B-1 (1:2:4) complete (excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in-charge.
Supply and fix in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed.
S&F in repair vitreous china corner wash hand basin including brackets, white size 550 x 400 mm including cutting for and pinning in ends of brackets, including Waste fittings, brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
S&F in repair pillar taps, swan neck type, 15mm bore cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts, screwed to iron pipe & fixed complete all as specified and directed..
S&F CP brass bib tap 15mm bore screwed for iron pipe or for brass ferrule complete all as specified and directed. Make-Cera/Parryware/Hindware.
S&F in repairs CP stop/angle cock fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair CP brass shower rose 15mm dia,100mm dia complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450 mm long complete all as specified and directed.
S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified and directed by Engr-in-Charge.
S&F in repairs Soap dish 6 inches, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repair sink/waste coupling 32mm dia PTMT half or full threaded complete all as specified and directed by Engr-in-Charge.
S&F in repair CP steel Grating round with steel frame with hinge 100mm dia all complete all as specified and directed by Engr-in-Charge.
S&F in repairs 32mm bore heavy duty waste pipe not less than 60cm long with PVC coupler for kitchen sink, WHB, urinal, etc complete all as specified and directed by Engr-in-Charge.
S&F in repair plate rack 300mm and size 100 x 80 cm made out of 1.00 mm thick stainless steel complete all as specified and as directed.
S&F in repairs stainless steel kitchen sinks without draining board ISI marked made of stainless steel 1 mm thick, with plugs, washers and wastes, including bedding lime cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engr-in-Charge.
M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like including demolition of old RCC, complete all as specified and directed.
M&L for use waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, chajja and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for TMT MS bar 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as specified .
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
Taking down CI/AC/PVC pipes incl fittings upto 110mm dia and removing from site complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed.
S&F PVC (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed.
S&F PVC nahani trap of 75mm bore, with grating including jointing to waste pipe with solvent fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S&F in repairs for 75mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F in repairs for 110mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and demolition of existing old cement concrete of plinth protection in ground floor and paving below or above ground level complete all as specified and directed.
M&L for coloured pre-polished rubber moulded chequred cement concrete tile 300mm x 300mm x 20-22mm thick with anti skid properties set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L 20 to 22mm thick for Machine cut kota stone slab flooring in one colour over 20 mm thick over CM 1:4 screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as spd and directed
All as per item No 88 here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
Supply and fix rotational moulded polyethylene water storage tanks capacity of tank 500 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, including ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball complete all as specified and directed.
S&F in repairs Gun metal gate valve iron wheel head screwed both ends for iron pipe of 20 mm bore complete all as specified and directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
Taking out & removing existing roof treatment of any description completely upto concrete surface including racking out joints, hacking for key,sweeping clean and scrubbing down with water etc to remove dust etc,complete all as specified and directed.
M&L for brushing neat cement slurry @ 3 Kg of cement per Sqm on cleaned roof/wall surface complete all as specified.
M&L for rendering 10 mm thick in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement in roof surface , complete all as specified and as directed.(Note- WPC shall be measured and paid separetely.)
Supply only integral water proofing compound as per manufacturers instructions ,complete all as specified.
M&L for Water proofing roof treatment with Polymeric water proofing membrane of weight not less than 3Kg/sqm and minimum 3mm thick, five layers with center core as 90 micron high molesuvre, high density polythene film sand witched between two layers of polymeric (Static polythene based) between laminated on both sides with 20 micron HMDPF film over a coat of hot blown bitumen with 85/25 grade @ 1.20 Kg/Sqm after priming the surface with bituminous emulsion @ 0.30 Litre/Sqm on plastered surface. Water proofing membrane should be laid with over laps 150 mm at ends and 75 mm for sides and shall be bounded uniformity by LPG torch flame over the polymeric water proofing membranes apply semi hot blown bitumen 85/25 grade @ 1.20 Kg/ sqm dusted sand over the coat of the coat @0.5 Kg/Sqm, and applying aluminium reflective paint over it complete all as specified and as per manufacturers instructions.
M&L in repair PU magnum water proofing treatment on chajjas (max area nexc. 2.0 sqm) including cleaning of existing surface, applying smart care mortar to fill cracks and joints followed by application of smart care Epoxy Primer 2k on the cleaned surface for bonding of PU magnum with the existing concrete surface complete all as specified and directed.
S&F in repair factory made RCC manhole cover of required size and shape and including removal of old unserviceable covers from site complete all as specfied and directed by Engr-in-charge. Make: Tulip/Sagar tiles
M&L for cement concrete 1:2:4 type B-2 (40 mm graded aggregate ) as in surface channel and drain complete all as specified and directed by Engr-in-Charge.
M&L for extra forming fair finished drain or channel 45 cm inner grith in cement concrete using extra cement , including formwork, moulds, mitred/stopped ends etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded agg) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation ,complete all as specified and directed.
M&L for 60 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment, complete all as specified and directed.
Taking out old damaged SGSW pipes from existing lines including necessary excavation in trenches and getting out in any type of soil alongwith supply, laying and jointing of new SGSW pipe type 'A' 150mm dia in any length including packing under and haunching against the sides of pipes in PCC 1:4:8 type D-2 (using 40 mm graded aggregate) and returning, filling in disposal of surplus soil to a distance n.exc 50m, complete all as specified and directed by the Engr-in-Charge.
S&F in repair stainless steel peg sets (minimum 5 hooks each) secrewed to wall ,complete all as specified and directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) alongwith steel conduit complete including switches, ceiling rose lamp holder, light fitting any type and fan regulator etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge.
M&L point wiring with 1. 5 Sqmm PVC insulated unsheathed multistranded single core copper conductor cable in PVC consealed wiring with PVC conduit wiring and incl making good with factory made modular pressed terminal box (recessed) with 1.5 Sqmm PVC insulated copper conductor earth continuity wire for one light/fan point controlled by one switch.
All as per item No.109 above but for Ceiling fan Point
All as per item No.109 above but for Exhaust fan Point
All as per item No. 109 above but for one pin 5 A socket outlet on same board
All as per item No. 109 above but for one pin 5 A socket outlet independent point
All as per item No.2 above but with 4 Sqmm cable for one 6 pin 15A socket outlet point on independent board
S&F switch piano flush, button type 5 Amp SP 250V AC complete.
S&F switch piano flush button type 15 Amps SP 250V AC complete.
S&F socket outlet 2-in-1, 5 Pin 5 Amps 250V AC complete.
S&F socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm. complete .
S&F LED tube light along with fixture,20 W including taking down old & U/s light fitting complete all as specified and directed.
S&F LED Mirror light fitting mirror type with high out put diffuser 2 feet, 9/10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down old & U/s light fitting complete allas specified and directed
S&F LED flood/street light 30/35 Watt Powered by built-in, isolated electronic LED driver including taking down old & U/s light fitting all as specified and directed
S&F fans BLDC ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , and connecting up ceiling rose t and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (Aas per site requirement) and necessary nuts and bolts including taking down old & U/s fan and deposited to MES stores complete all as specified and directed.
S&F Exhaust fans Metallic AC single phase 230/ 240 V of size 300 mm sweep,50 Hz with louver of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
S&F Exhaust fans AC single phase 230/ 240 V , made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
S&F Water heater storage type, electric, capacity 25 litres AC single phase 230/ 240 V o and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
S&F Sheet metal enclosures with socket plug top and MCB' SPN enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB
S&F TPN DB VTPN 6 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement including and fixing of DPX3 MCCB 125 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Engr-in-charge,
S & F sheet metal enclosure DB SPN when MCB's to be used 12 way with 200 amps bus bar and double door complete all as specified and directed.
S&F MCB SPN 240 Volt 10 KA 40 Amp conforming to IS complete all as specified & directed.
S&F MCB SP 6 to 32A
M&L for submain wiring with 3 runs(N+P+E) of 1.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed/surface PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-3 runs of 1.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 25 but with 3 runs(N+P+E) of 2.5 Sqmm single core copper FRLS conductor . Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 25 but with 3 runs(N+P+E) of 4 Sqmm single core copper FRLS conductor .Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 25 but with 6 runs(3 runs P+N+ 2 run Earth) of 6 Sqmm single core copper FRLS conductor and PVC conduit not less than 24 mm dia. Note:-6 runs of 6 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI earth strip 4 Sqmm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed.
S&f electronic meters temper proof, single phase LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed
Supply and Laying XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 50 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unsv LT Cable for laying of cable and getting out.
Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed by Engr-In-Charge.
Removing excavated material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified.
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed
Cutting existing road/hardstand of any type by using crow bar chisel uprto a depthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
M&L for GI Tubing Light grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 50mm dia (make: prakash surya/jindal/TATA)
PARAMOUNT ENGINEERS (BID ID -3129040)
Shree Durgai Construction Co. (BID ID -3127728)
AYUSH CONSTRUCTION COMPANY (BID ID -3137352)
VERDHMAN ASSOCIATES (BID ID -3129904)
G.H. INFRASTRUCTURE PRIVATE LIMITED (BID ID -3129927)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .