Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
20 Oct 2021, 6:00 pmClosed
GE SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
SPECIAL REPAIR TO BLDG NO T-41,T-42, S-21 AND CERTAIN MINOR WORK AT MASIMPUR MIL STN UNDER GE SILCHAR
2021_MES_478522_1
8664/E8
Open Tender
Civil Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹77,000
Yes
31 Dec 2021
29 Sept 2021
21 Oct 2021
29 Sept 2021
20 Oct 2021
14 Oct 2021
Amount
PART-I (B/R WORKS) Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth and getting out in soft/loose soil, complete all as specified & directed.
Excavation over areas, n exc 1.5 m deep and getting out and getting out in soft/loose soil, complete all as specified & directed.
Excavation over areas, exc 1.5 m but n exc 3 m deep and getting out and getting out in soft/loose soil, complete all as specified & directed.
Returning, filling in with soil obtained from excavation including spreading levelling watering and well ramming in layers not exceeding 25 cm, complete all as specified & directed.
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified & directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness,including Nainital or similar pattern roof coverings, asbestos ( corrugated or semi corrugated as in roof covering, complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed.
Demolition of reed lathing, single or double including battens and plaster or chicken wire lathing complete all as specified & directed.
Dismantling timber boarding of any description fixed in any position with nails complete all as specified and directed.
Dismantling of timber fillets rails, posts, rafters, purlins etc under 40 Sqcm in section, in any position in unframed work complete all as specified and directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position, unframed work, etc complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, etc complete all as specified & directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Demolition cement concrete (un reinforced) of any description for ground floor and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified & directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4 sqm each complete all as specified
Taking down Shutters of any description n exc 1 sqm each complete all as specified & directed.
Taking down & refixing of Shutters of any description exc 1 sqm and n exc 2 sqm each in same or other position complete all as specified
Taking down Shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified
Taking down cement plaster on brick or stone walls etc. including raking out joints hacking for key scrubbing down with water complete all as specified & directed
Taking up or down 15mm dia GI steel tubing and connections complete all as specified & directed
Taking up or down 20mm dia GI steel tubing and connections complete all as specified & directed
Material and labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in surface channels & drains complete all as specified and directed.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified and directed.
All as per item No. 26 above but 6mm to 8 mm dia complete all as specified and directed
All as per item No. 26 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed
Material and labour for reinforced cement concrete 1:1.5:3 type A-1 using 20 mm graded crushed stone in slabs supported on walls, beams etc ,complete all as specified and directed.
Material and labour for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified & directed.
M&L for providing precast cement concrete 1:2:4 type B1 using 20 mm graded aggregate and set in CM 1:4 in landing, cover slabs(for main holes), chullah hoods, chajjas, water trough,mangers, shelves and similar articles with plain faces incl formwork complete all as specified and directed.
Material and labour 25 mm thick cement concrete 1:2:4 type B0 using 12.5 mm graded aggregate in floors finished the surfaces even & rough to receive topping layers complete all as specified and directed
Material and labour for PCC 1:2:4, type B-1, using 20 mm graded stone aggregate as in benching/kerbs and levelling course or similar works etc, complete all as specified and directed.
Material and labour for cement concrete 1:2:4 as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating , includiong necessary formworks, complete all as specified and directed.
Material and labour brick work with sub class ‘B’ brick straight in one brick thick honey comb work built in cement mortar 1:3 complete all as specified and directed
Material and labour brick work with sub class ‘B’ brick straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Material and labour brick work with sub class ‘B’ brick straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1: 4 complete all as specified and directed.
Material and labour for half brick work with sub class 'B' bricks straight or curved on plan to radius built in cement mortar 1:4 complete all as specified and directed.
Material and labour rendering 10 mm thick in CM 1:6 on fair faces of brick work or concerete surfaces finished even and smooth without using extra cement complete all as specified & directed.
Material and labour rendering 15 mm thick in CM 1:6 on the ‘other’ side of lathing surfaces finished even and smooth without using extra cement complete all as specified & directed.
M&L rendering 15 mm thick cement rendering on fair faces of brick wall or concrete surfaces in CM (1:4) finished fair and even complete all as specified & directed.
M&L rendering 15 mm thick cement rendering in two layer each of 10+5 mm thick on fair faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified & directed. Note -WPC shall be measured and paid separately.
M&L rendering 15 mm thick cement rendering in two layer each of 10+5 mm thick on one side of lathing in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified & directed. Note -WPC shall be measured and paid separately.
Supply only water proofing compound complete all as specifid and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
All as per item No. 45 above but as in skirting/dado on walls , complete all as sepcified and directed.
Material and labour Non-skid colour ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed in cement slurry and pointed in white or colour cement to match existing surfaces over & including 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes complete all as specified & directed
Material and labour Non-skid colour ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in skirting set and jointed in cement slurry and pointed in white or colour cement to match existing surfaces over & including 10 mm thick screed bed or bedding layer of cement mortar 1:4, for laying floor finishes complete all as specified & directed
Material and labour of Glazed ceramic coloured tiles in vertical surfaces size 450 x 300 x 6 to 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10 mm thick screed bed or bedding layer of cement mortar 1:4, for laying floor finishes complete all as specified & directed
Material and labour for 15 mm thick screed bed or bedding layers of cement mortar 1:6 for laying floor finishes complete all as specified & directed.
Material and labour for 10 mm thick rendering of cement mortar 1:4 to receive tiles invertical surfaces complete all as specified & directed.
M&L for rubber moulded precast concrete inter locking paver blocks any shape and size confirming to IS 15678-2007 of 80 mm thick M-40, complete all as specified and directed.
M&L for Sand filling under floors or in foundations or in cushions for interlocking tiles spread levelled including watering and consolidation etc complete all as specified and directed.
Supply and fix PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & directed.
Supply and fix 2nd class hard wood as in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified & directed.
Supply and fix Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door frames with one or more rebates including hinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and directed.
Supply and fix 30 mm thick second class hardwood glazed and skeleton shutters for ventilator/windows, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars,. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified.
M&L for for PCC1:3:6 type C-0 using 12.5mm graded aggregates as in fillings of steel chowkhatsand holdfast including necessary formwork complete all as specified and directed.
Material and labour flush shutters, 35mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides including 6/8mm thick polished teak wood lipping alround the door properly fixed complete all as specified & directed.
Material and labour Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame as site as per specification & drawing complete all as specified & directed.
M&L for Second class hard-wood clean sawn in scantlings complete all as specified and directed.
M&L for Second class hard-wood wrought as in scantlings complete all as specified and directed.
M&L for 4 mm thick Asbestos cement plain building boards, fixed to timber framework with screw as in ceiling complete all as specified and directed.
M&L for Second class hard-wood as in plain fillets exc 6sqcm but not exc. 13 sqcm square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
M&L for Second class hard-wood as in plain fillets bull nosed, splayed, chamfered or rounded on one edge or faceexc 13 sqcm but not exc. 25 sqcm square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
M&L for Second class hard-wood as in plain fillets exc 13 sqcm but not exc. 25 sqcm square, rectangular or triangular in section, wrought, secured with nails or brads complete all as specified and directed.
M&L for 2nd class hard wood 50 mm thick boarding wrought as in purlin, rafter etc fixed with nails complete all as specified and directed.
M&L for small articles of 2nd class hard wood such as hinge blocks, door and window stops articles not exc 200 cubic centimeter each and fixed with ateel screws, complete all as specified and directed.
Supply & fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
Supply & fix Wire netting of galvanised steel wire 0.71 mm dia & 12 mm mesh fixed with tinned tacks of wire staples complete all as specified and directed.
Supply and fix aluminium handles, fabricated type, anodised 125mm long fixed with screws, complete all as specified and directed.
S&F aluminium sliding door bolt, 250 mm, plate type, stove enameled black, with bright bolt not less than 12 mm dia, with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Supply and fix Framed work such as grills, gratings, etc. with ends of bars or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe 290 Gde E-165, complete all as specified and directed.
Supply and fix Steel windows with side hung shutters including box type hinges with steel handles, 2 Nos steel tower bolts 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified & directed.
Supply and fix Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement laid in panels and joints filled with bituminous 1 part and 3 part of sand complete all as specified and directed.
Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified & directed.
Supply and fix 100 mm long butt hinges, medium weight, of stainless steel fixed with stailless steel screws and fixed complete all as specified & directed.
Supply and fix 75 mm long butt hinges, medium weight, of stainless steel fixed with stailless steel screws and fixed complete all as specified & directed.
Supply and fix 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified & directed.
Supply and fix 125 mm long aluminium handle cast type anodised complete all as specified & directed.
Supply and fix 100 mm long aluminium handle cast type anodised complete all as specified & directed.
Supply and fix MS Rolled sections( Fe-290, Gde E-165) as in main and cross beams, hip and jack rafters, purlins where connected tocommon rafters and other misc brackets, fixed with angle cleats or other connecting plates etc.complete all as specified and directed.
Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600 mm grid and painted with two coats of acrylic emulsion paint of approved shed /make over a coat of cement primer before installing it on the grid all as specified and directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed..
Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Material and labour for providing 100 mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of floor rough surface complete all as specified and directed.
Material and labour for providing 75 mm thick plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in sub base of floor rough surface complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished surface of concrete , complete all as specified and directed.
Cutting grooves or rebates not exceeding 15 cm girth, and trimming with or without reinforced surfaces complete all as specified & directed
Supply and fix in GI tube 15 mm dia (ISI Marked) medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and directed.
Fixing only old steel tubing of 15mm bore and connections in new or old position (walls, ceiling, floors, etc) including cleaning or returning the old screw threads incl new GI fittings as required complete all as specified & directed Note : Serviceable steel tube obtained from taking down shall be reused.
Supply and fix in GI tube 20 mm dia (ISI Marked) medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and directed.
Fixing only old steel tubing of 20mm bore and connections in new or old position (walls, ceiling, floors, etc) including cleaning or returning the old screw threads incl new GI fittings as required complete all as specified Note : Serviceable steel tube obtained from taking down shall be reused.
Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed
Supply and fix, vitreous china squatting pan of Orrisa pattern size 580 mm x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including 'P' or 'S' trap and lime concrete bedding connection making good to floor fixed in repairs complete all as specified.
Supply and fix, Vitreous China urinals, half stall type flat back,white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified.
Supply and fix in repairs PVC valveless, syphonic action type, low level PVC flushing cistren 10 ltr cap white with flush pipe & all fitting and flush pipe complete all as specified & directed
Taking down PVC flushing cistern & refixing after repairs complete all as specified & directed
Supply and fix, as in repair, 15 mm bore bib taps fancy type, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed
Supply and fix as in repair 15 mm bore pillar tap fancy type, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe complete all as specified & directed
Supply and fix, as in repair, angle stop valve fancy type, cast copper alloy, chromium plated, screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions complete all as specified & directed
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate)bed to drain pipe for 110mm bore including packing under haunching against side of pipe after they are laid and tested, complete all as specified and directed
Supply and fix 110 mm bore PVC (SWR) Pipe single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified & directed.
Supply & fix in repairs PVC (SWR) Pipe 75 mm bore single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
Supply and fix 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
Supply & fix PVC (SWR) vent cowl 75 mm bore any radius complete all as specified and directed.
Material and labour for preparation of new or untreated steel surface of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified.
Material and labour for preparation for old treated steel surface of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint complete all as specified.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
Material and labour for preparation of old treated wood and wood base surfaces of any description, not otherwise described n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
M&L for preperation of old painted wooden surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over new surfaces preparation of new or previously untreated wall surface complete all as specified & directed
M&L for complete removal of existing treatment and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over new surfaces preparation of new or previously untreated wall surface complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coat of oil emulsion distemper over one coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coat of oil emulsion distemper over one coat of primer complete all as specified and directed.
M & L for preparation of new or previous untreated surfaces and applying three coats of white wash on walls surface complete all as specified and directed
M & L for preparation of new or previous untreated surfaces and applying three coats of white wash on ceiling surface complete all as specified and directed
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coat of white wash complete all as specified and directed.
Material and labour for preparation of old decorated ceiling surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coat of white wash complete all as specified and directed.
PART-II (E/M WORKS)Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed.
Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated cable with stranded copper conductor of size 6 Sq. mm nominal area drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box including one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit will be measured as one unit.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. all as directed.
M&L for Point wiring using 1100 volts FRLSH PVC insulated unsheathed multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc for one light/fan/bell point complete all as specified and directed.
All as per item No.126 above but for 5 Amps socket Point on same board complete all as specified and directed
All as per item No.126 above but for 5 Amps socket Point on Independent board, complete all as specified and directed
All as per item No. 126 here in before but using 1100 volts FRLSH PVC insulated unsheathed multi strand copper conductor cable 2.5 sqmm including 2.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc for one 15 Amp socket outlet complete all as specified and directed.
Supply and fix ceiling rose surface bakelite with three terminals all as specified and directed.
Supply and fix switch piano flush type button single pole one way 5 Amps , complete all as specified and directed.
Supply and fix socket outlet 3/5 pin 5 Amps flush type complete all as specified and directed.
Supply and fix switch socket boutlet 3pin 5 Amp and 5/6 pin 15 Amp 2 in 1 universal, complete all as specified and directed.
Supply and fix ceiling fan regulator socketed, step type flush type heavy duty 230 volts, complete all as specified and directed.
Supply and fix wall mounted LED batten for 20 watt LED tube rod both side connection box type complete all as specified. Make:- Crompton, Product Code : IGP161LT8-16 or equivalent make of Philips/Bajaj/Wipro/Syska LED/M/s Surya Roshni Limited /M/s Jaquar & Company Pvt Ltd
Supply and fix wall mounted LED tube rod 22 watt, pin on both side suitable for fixing upto 22 watt battens complete all as directed. Make : Make : Crompton Cat No. LT8-8-565-2 or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/
Supply and fix street /bldg security light LED luminaire 20 watt IP 66 LED lamp, driver etc, including service bracket with all accessories as specified and directed. Make: Crompton Cat No. LSTS-20-CDL-M or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Havells
Supply and fix in repair plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. Make :- BAJAJ MAXIMA DX 5 BLADE (250 MM ) or equivalent.
Dismantling old unserviceable main switches, Sheet metal enclosures DB including MCBs etc and keeping in safe custody either for reuse or for disposal including making good to the disturbed surfaces of wall all as directed.
Supply and fix sheet metal enclosure powder coated single phase and neutral DB for fixing of MCBs, 8 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix MCB SP 240 volts, 50 Hz capacity 6-32 Amps all as specified and directed
Supply and fix MCB SPN 240 volts, 50 Hz of capacity 40 Amps all as specified and directed
Taking down carefully ceiling fan of any type from existing location carrying out cleaning and servicing , removing the burnt out copper winding from ceiling fan and cleaning of slots & then re-winding with super enamelled wire of existing gauge incl all associated materials such as super cotton tape, film paper dry inmlation varnish, tape, insulation etc and heating, varnishing, replacement of bearings of suitable size etc and testing and refixing in existing / new location with provn of ‘S’ type fan hook including connecting electrically with provn of new cable including painting of fans complete, in situ with approved synthetic enamel paint by spraying including filling cavities with filler, writing MES Nos in Roman Block letters / figures complete all as specified & directed.
Supply and lay cable or fixed to wall/floors XLPE insulated, PVC bedded, Galvanised steel strip or wire armoured, Electric power cable heavy duty with stranded alluminium conductors,1100 volt grade, 35 Sq mm, 3.5 Core, laid through duct/pipr/in trenchesetc with cable glands & suitable size of aluminium lugs, all as specified and directed.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Material & labour GI tube light grade 25mm for protection of UG cable including dismantling of old unsv pipe complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of MES Schedule 2009 Part-I complete all as specified and directed.
MS AFTAB LASKAR
MAGADH TRADING
M/S MOLOY KUMAR DEY
M/S TAPAN KUMAR RAY
SURANA CORPORATION
M/S RAJU ENTERPRISES AND BROS
m/s builders and suppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .