Executive engineer electrical deptt
jk sidco electrical deptt bari brahmana
Design supplying Installation Testing and Commissioning of 12 Mtr. High Mast light at Industrial Complex Ghatti Kathua
2023_SIDCO_226250_2
Enit 10 of 2023-24
Open Tender
Electrical Works
Item Rate
30 days
jk sidco bari brahmana
Please refer to tender document
2 documents required · 2 mandatory
₹1,500
Executive engineer electrical deptt
₹15,000
8 Sept 2023
14 Aug 2023
28 Aug 2023
14 Aug 2023
26 Aug 2023
14 Aug 2023
Amount
High Mast Pole:- Design /Supplying/ Installation/ Testing and commissioning of 12 Mtr.GI Type high mast shaft in two sections suitable for 47 M/ Sec wind speed with Raising Lowering system comprising head frame, Luminaries, Carriage suitable to Install 6 No Luminaries in symmetrical arrangement, double drum with 5 mm Dia meter SS wire Rope, Trailing Cable, connector, Integral. Power, tool motor of 1HP capacity 3 Phase type, manual handle, wiring material, power cable between panel and mast. P/F of foundation Bolts manufactured from special steel along with nuts, washers, anchor plate and common template, P/F of Twin Dome LED aviation obstruction light 10 Watt each. Job also includes construction of shallow foundation with M 20 grade concrete for the high mast considering the safe soil Dearing capacity and site as 10T/ Sq Mtr. at 2 Mtr. depth with all material &labour.
Connection Wire:- Supply and drawing of 3 core 1.5 Sq.mm PVC insulated copper cable with Lugs complete job with connection etc as required
Power Cable :- Supply, laying, testing and commissioning of 1.1 KV grade Aluminum conductor PVC insulated PVC sheathed, steel armoured cable, 0.75 M below ground including digging of trench 0.35 M wide 0.75 M depth through HDPE pipe 40 mm dia (Pn8) and refilling the trench, etc as required. The job includes cost of PDPE pipe complete job. a) 4x10 Sq mm (with pipe)
Led Fitting:- Supply, erection, testing & commissioning of LED fitting cat No BENP 21 FL 160 Watt including connection etc. Complete job in all respect
Earthings Making of earthing station using chemical type 50 mm Dia G.I Earth electrode maintenance free & providing masonry enclosed with cover plate having locking arrangement as required.
G.I Wire Supplying & laying of 6 SWG G.I Wire on surface & in recess for loop earthing along with cable as required.
Control Panel:- Supply, installation, testing & commissioning of control panel dust vermin & weather proof out door canopy type of suitable size made of 14 SWG MS Sheet having holes at Bottom for incoming & outgoing of cables. It should be painted with one coat of primer & two coats of approved make & color of synthetic enamel paint& grouting the same. The panel comprising of following items TPN 32 Amp------- 1 No. Phase indicator R/Y/B- 1 Set Automatic Timer ---------- 1 No Contactor 25A TP------- 1 No for timer. Contactor 9ATP for Raise/ Lower Purposes. ---------- 2 No Push Buttons ------------ 2 No MCB SP 10 Amp------ 6 No
GLOBAL ENGINEERS
Ashok Kumar
VEE GEE ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .