Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹16.3 L+₹1.4 L (9.49%)Rejected-AOC | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹17.5 L+₹2.6 L (17.6%)Rejected-AOC | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹18.0 L+₹3.1 L (21.0%)Rejected-AOC 208 L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L4 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 5 | L5₹18.7 L+₹3.8 L (25.5%)Rejected-AOC | L5 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
₹21.3 L
EMD Value
₹42,500
Closing Date
9 Dec 2019, 6:00 pmClosed
CWE Mamun
HQ CWE Mamun Pathankot-145001
SPECIAL REPAIR TO BUILDING NO P-16 AT MIL STN SAMBA
2019_MES_295421_1
CWE/M-29/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE Samba
Class E category a i
6 documents required · 6 mandatory
₹500
Yes
GE Samba
₹42,500
Yes
27 Jan 2020
6 Nov 2019
10 Dec 2019
6 Nov 2019
9 Dec 2019
25 Nov 2019
Amount
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Demolition of cement concrete (unreinforced) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified.
Dismantling timber scantlings 40 Sqcm and over in section, in any position and unframed/framed work complete all as specified complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Taking down cement plaster from chajjas / faia etc incl dismantling of demaged concrete & repairing the same with PCC 1:2:4 type B-0 ( using 12.5 mm mgraded stone aggregates) & applying 10mm thick cement plaster in cement mortar (1:4) using liquid water proofing compound & finishing the surface even and smooth using extra cement complete all as specified & directed. (Note : WPC shall be measured and paid separately)
Taking down chowkhats or frames of any description not exc. 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware complete all as specified and directed.
Taking down chowkhats or frames of any description exc. 1.50 Sqm and n.exc 4.00 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware complete all as specified and directed.
Taking down Shutters of any description not exc 1 sqm each including builders hardware complete all as specified and directed.
Taking down Shutters of any description exc 1 sqm and n exc 2 sqm each including builders hardware complete all as specified and directed.
Taking down wooden shutter of any description exceeding 1 sqm and not exceeding 2 sqm each and refixing in same opening including necessary minor repair and adjustment of shutter etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisesr complete all as specified and directed.
M&L for Rendering 15mm thick in cement mortar (1:4) using liquid water proofing compound on roof padding brick work or concrete surfaces of wall surfaces finished even and smooth using extra cement complete all as specified & directed. (Note : WPC shall be measured and paid separately)
M&L for 25 mm thick floor in PCC 1:2:4 type B-0 as in floor finished even & fair to receive tiles/ kota stone complete all as specified and directed.
M&L for Brick work with Fly Ash Brick (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) incl dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc and removal of rubbish out off the premises complete all as specified and directed.
Labour only (except bricks) for brick work (with serviceable bricks retrieved from dismantling straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed. [Note: Serviceable Brick retrived from srl. 14 above will be reused in this work]
M&L for RCC 1:1.5:3 type A-1 using 20mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork including demolition of existing cover slabs of any description and removal of rubbish out off the premises etc complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) such as in benching, coping, Bed blocks , broken chajjas and the like, rounded or chamfered on edges including necessary formwork complete all as specified and directed.
M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L Rendering 10mm thick cement plaster on fair faces of ceiling surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 15mm thick in two layers (base layer 10mm & finishing layer 5mm thick) in cement mortar (1:4) using liquid water proofing compound ( In 2nd Coat only)on brick work or concrete surfaces of wall surfaces finished even and smooth using extra cement complete all as specified & directed. (Note : WPC shall be measured and paid separately)
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform & and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4), incl. rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joint free tiles 8mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joint free tiles 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joint free tiles 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm on vertical surfaces in skirting (to match flooring tiles), set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surfaces finished even and rough to receive tiles, complete all as specified and directed.
M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surface finished even and rough to receive tiles, complete all as specified and directed.
M&L for 20-25mm thick Kota stone slab (Pre-mirror polished), set and jointed in neat cement slurry and pointed in coloured epoxy grout to match including rounding the edges over and including 20mm thick screed bed in CM 1:6, surfaces finished even and rough to receive kota stone complete all as specified and directed.
M&L for kota stone floor 18-20 mm thick, as in riser of steps, skirting, dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in cement mortar (1:4), surfaces finished even and rough to receive kota stone complete all as specified and directed.
M&L for Rubbing , Grinding, mirror finish polishing to existing tezzazo topping as in floor / skirting nd rounding off edges of glass, any type complete all as specified and directed.
M&L for factory made PVC internal door frame of the size 100mm x 45mm with a wall thickness of 5mm, made out of extruded 5mm thick prelam PVC sheet of density 600kgs/cbm manufacturured by an ICO-9000 certified company mitre, mitre cut at two corners and joined with 4 nos of 150mm long brackets of 1500 x 1500 M.S tube of 19 guage through out the frame. The door frame shall be fixed to the wall using 65/100mm long M.S screws to be provided for each vertical member & minimum 2 nos for horizental members etc. complete as per manufactures specification and direction of Engr-in-charge.
M&L for pressed steel frames 105mm x 60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed.
M&L for pressed steel frames 125 mm x 60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl 02 coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing using steel conforming to Fe-290 (Gde E165) complete all as specified and directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for Factory made solid PVC moulded door shutters, 28 to 30mm thick (stiles), with PVC solid board core not less than 18mm thick and 2, 4, or 6 raised panel design with 5mm thick moulded prelam PVC sheet on the front face & 5mm thick prelam PVC sheet on back face, supplied and fixed in frame at site as per specification and shown in SSR Part-II Section-8 complete all as specified and directed.
M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faceS ,The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, fitted to chowkhats incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed.
M&L for 35mm thick glazed and skeleton shutters (Factory made) of 2nd class hard wood open rebated kiln seasoned & chemically pressure treated and prepared to receive glass/gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24(a), fitted to chowkats including preparation of surfaces of shutter and application of two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side hung wire gauged shutter & glass/glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg, welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts fixed in PCC blocks all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 300 mm aluminium alloy sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing sliding bolt of extruded section complete all as specified and directed.
M&L for Aluminium anodised handle, extruded section of size 150mm complete all as specified and directed.
M&L for Aluminium anodised barrel tower bolt, extruded section 200mm long , complete all as specified and directed.
M & L for 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
M & L for Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
M&L for stainless steel Butt hinges of size 100 mm fixed with steel screws of appropriate size complete all as specified and directed.
M&L for Mild steel powder coated door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate including necessary welding etc complete all as specified and directed.
M&L for Plain fillets. square, rectangular or triangular in section, clean sawn, se-cured with nails or brads not exc 3 sqcm using second class hard wood complete all as specified and directed.
M&L for Plain fillets. square, rectangular or triangular in section, clean sawn, se-cured with nails or brads exc 6 sqcm not exc 13 sqcm using second class hard wood complete all as specified and directed.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane incl hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
M&L for 3mm thick figured glass, pin head type and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.
M&L for 3mm thick figured glass, pin head type and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane incl hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
M&L for Stainless steel wire cloth 0.34mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
M&L for Stainless steel wire cloth 0.34mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks or galvanized wire staple fixed in repairs complete all as specified and directed.
M&L for 40 mm thick floor in PCC 1:2:4 type B-0 finished even & smooth, including dismantling existing floor of any type and pattern and removal of rubbish out off the premises complete all as specified and directed.
M& L for 38 mm wide Glass dividing strips, 3 mm thick inserted in position, conform to design complete all as specified and directed.
M& L for Plain Cement concrete Type F2 ( 1:7:12 ) as in foundations, filling and mass concrete all as specified and directed.
M& L for Plain Cement concrete Type C-2 ( 1:3:6 ) as in surface channels and drains incl mould / Formwork complete all as specified and directed.
M&L for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
M&L for PVC (SWR) rain water pipes of 110 mm bore dia in any length, with rubber ring joints, fixed to walls with stack clamp made out of 25mm by 2 mm galvanised iron flat fixed with bolt and nuts, including taking down existing CI/SWR pipes etc complete all as specified & directed.
M&L for PVC (SWR) rain water pipes of 75 mm bore dia in any length, with rubber ring joints, fixed to walls with stack clamp made out of 25mm by 2 mm galvanised iron flat fixed with bolt and nuts, including taking down existing SWR pipes etc complete all as specified & directed.
M&L for PVC (SWR) rain water pipes of 110 mm bore dia in any length, with rubber ring joints,laid in trenches or as in floor including taking down existing SWR pipes etc incl earthwork if required complete all as specified & directed.
M&L for PVC (SWR) rain water pipes of 75 mm bore dia in any length, with rubber ring joints,laid in trenches or as in floor including taking down existing SWR pipes etc incl earthwork if required complete all as specified & directed.
S&F 110 mm bore bends PVC (SWR) (any radius) fixed with cement solvent etc complete all as specified and directed.
S&F 110 mm bore bends PVC (SWR) (any radius) provided with oval access door fixed with cement solvent etc complete all as specified and directed.
S&F 75 mm bore bends PVC (SWR) (any radius) fixed with cement solvent etc complete all as specified and directed.
S&F 75 mm bore bends PVC (SWR) (any radius) provided with oval access door fixed with cement solvent etc complete all as specified and directed.
M&L for 75 mm PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), fixed in repair including taking down existing floor trap, complete all as specified and directed
S&F in repair 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal ordinary or inverted (spigot or socket type) or with parallel branches fixed with cement solvent etc complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) vent cowl jointing with solvent cement complete all as specified and directed.
S&F in repair for PVC (SWR) gully trap 125/110mm, jointing with solvent cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight including dismantling existing floor of any type and pattern and removal of rubbish out off the premises complete all as specified and directed.
S&F 20mm bore dropery Curtain rod, with suitable bracket and ,end caps, fixed in repair complete all as specified and directed.
M&L for 18 to 20mm thick prelaminated PVC solid board with acrylic lamination not less than 0.50mm thick (one side decorative choice laminate and other side balancing white) having weight not less than 9 Kg/Sqm and average density ranging from 500-700 Kg/Cum fixed as in kitchen cabinet, cupboard and pelmet box fixed with screws to PVC/timber frame work complete all as specified and directed.
M&L for 18 to 20mm thick prelaminated PVC solid board with acrylic lamination not less than 0.50mm thick (both side decorative choice laminate ) having weight not less than 9 Kg/Sqm and average density ranging from 500-700 Kg/Cum fixed as in kitchen cabinet, cupboard and pelmet box fixed with screws to PVC/timber frame work complete all as specified and directed.
M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
All as per Srl tem No 77 above but except pipes ( Refixing old retrived serviceable Pipes) ( Refixing old retrived serviceable Pipes) but with all new fittings complete all as specified and directed.
M&L for GI water tubing surface/concealed, 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
All as per Srl tem No 79 above but except pipes ( Refixing old retrived serviceable Pipes) but with all new fittings complete all as specified and directed.
Cutting chases not exceeding 10cm in width/girth for concealed water tubing or concealed conduit wiring and making good in cement mortar 1:3 to match existing surface complete all as specified and directed.
M&L for rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball complete including taking out existing water tanks of any description all as specified & directed.
M&L for rotational moulded polyethylene water storage tanks three layer of capacity 1000 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball complete including taking out existing water tanks of any description all as specified & directed.
M&L for vitreous china White Squatting Orissa Pattern pan (Make : Somany Cat part No 121115 or equivalent model in Hindware/Parryware) of size 580x440mm, including cast iron ‘P’ or ‘S’ trap, front or back inlet and integral foot rests and making connection to trap and to flushing pipe, anti syphonic pipe ifixed in repairs and making good to disturbed floor matching with existing finishes complete all as specified and directed.
S&F in repair for Vitreous china white wash down water closet pan (pedestal pattern) with normal closing seat cover S-trap (Make : Jaquar Cat part No CNS-WHT-553SN or equivalent Cat Part/Model of Hindware/Parryware/ Somany) & hand shower (Health foucet) 8mm dia 1m long flex tube in chrome finish and wall hook with NRV (Back flow preventer) and connection to drain (or out going pipe) (Make : Jaquar Cat Part No ALD-577 or equivalent Cat Part/Model of Hindware/Parryware) and to flush pipe, antisyphonic pipe etc complete all as specified and directed
S & F of PVC flushing cistern 10 Ltr capacity, valve-less syphonic action type, low level, complete with inlet, ball valve, handle, including brackets/pins, PVC flush pipe 32mm bore and PVC connection 15mm bore 450mm long complete all as specified and directed.
S & F Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent model in Hindware/Parryware/Somany) brackets, CP waste coupling, 32mm bore PVC waste pipe of min 600mm long, including cutting for and pinning in end of brackets or erecting stand fixed in repairs complete all as specified and directed.
S & F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No FLR-5011N or equivalent model in Hindware/Marc.) fixed in repairs complete all as specified and directed.
S & F 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule, fixed in repairs complete all as specified and directed. Make : Jaquar Cat part No FLR-5047N or equivalent model in Hindware/Marc.
S & F 15mm bore chromium plated angle valve / stop valve with wall flange of cast copper alloy, with capstan head, screwed both ends for iron pipe or for unions fixed in repairs complete all as specified and directed.
S & F 15 mm bore stop valves concealed fancy type , cast copper alloy, chromium plated long shank & cup screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F 15 mm bore stop valves concealed fancy type , cast copper alloy, chromium plated long shank & cup screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions fixed in repairs complete all as specified and directed.
S & F Tubular towel rail brass chromium plated , 20mm dia, D type, 60cm long between flanges fixed in repairs fixed in repairs complete all as specified and directed.
S & F PVC connection 15mm size with PTMT nuts of length 450mm long of appoved make fixed in repairs complete all as specified and directed.
S & F Sink with drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairs complete all as specified and directed. CAT part No BSSBSD-52 or equivalent Model of Jyoti/Nirali
S & F Brass Chromium Plated shower rose with arms fancy type with swivel joints 75 mm face dia of appoved make and cat part for 15mm bore iron pipes fixed in repairs complete all as specified and directed. Make : Prayag Cat part No BS-73 or equivalent model in Hindware/Marc.
Supply only Polymer liquid water proofing compound of make Pidilite/Bauchemic/Fosrock, all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint over a coat of primer as per manufacturer instructions complete all as specified and directed.
M&L for Preparation of exisiting cement base painted surfaces of wall applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over a layer of wall care putty not less than 2mm thick complete all as specified and directed.
M&L for Preparation of existing distempered surfaces of walls and apply one coat of distemper oil emulsion (OBD) complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and apply three coats of white wash on plastered surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and apply three coats of white wash on plastered surfaces complete all as specified and directed.
M&L for preparation of existing white washed surfaces of ceiling and apply two coats of white wash on plastered surfaces complete all as specified and directed.
M&L for preparation of existing white washed surfaces of walls and apply two coats of white wash on plastered surfaces complete all as specified and directed.
M&L for preparation of existing painted steel surfaces of any description, not otherwise described, over 10cm width or girth & applying one coat of synthteic enanel paint complete all as specified and directed.
M&L for preparation of existing painted wooden surfaces of any description, not otherwise described, over 10cm width or girth & applying one coat of synthteic enanel paint complete all as specified and directed.
Taking down carefully unserviciable/ damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLS PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit of appropriate size but not less than 25mm dia and 1.8mm thick flexible with all accessories and FRLS PVC insulated 1.5 Sqmm multi standard unsheathed copper wire for continues earth, with inner, outer frame plates including metal flush sunken boxes with zinc oxide plated suitable size for mounting switches, sockets, fan regulators etc connecting earth dolly with PVC unsheathed flexible copper conductor green in color and making good to the disturbed surface of wall/floor and matching with existing specifications for one light/fan/bell point controlled by one switch complete all as specified and directed. Make of wire : Polycab/Havells/Finolex/HPL.
All as per Srl item No.110 above but for one light point controlled by 02 , 02 way switch complete all as specified and directed.
All as per Srl item No.110 above but for 5 Pin 5 Amp socket outlet point on independent board with separate switch 5 Amp one way, complete all as specified and directed.
All as per Srl item No. 110 above but for 5 Pin 5 Amp socket outlet point on same board with separate switch 5 Amp one way, complete all as specified and directed.
All as per Srl item No. 110 above but for one 15Amp socket outlet point concealed using 2.5 Sqmm FRLS PVC insulated multi-strand copper conductor wire including 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes complete all as specified and directed.
S & F modular switch piano type flush button one way 06/10 Amp one module complete all as specified and directed. Make : Legrand Cat Part No 673000/Crabtree Cat Part No ACMSXXW101/Anchor Roma Cat Part No 66111.
S & F modular switch piano type flush button two way 06/10 Amp one module complete all as specified and directed. Make : Legrand Cat Part No 673001/Crabtree /Anchor Roma
S & F modular switch piano type flush button 16 Amp one module, complete all as specified and directed. Make : Legrand Cat Part No 673009/Crabtree Cat Part No ACMSXXW102/Anchor Roma Cat Part No 66104.
S & F modular socket 2 module 5/6 pin 6/10 Amp,complete all as specified and directed. Make : Legrand Cat Part No 673044/Crabtree Cat Part No ACMKUXW133/Anchor Roma Cat Part No 66403.
S & F modular socket 16 Amp 5/6 pin two module complete all as specified and directed. Make : Legrand Cat Part No 673455/Crabtree Cat Part No ACMKCXW163/Anchor Roma Cat Part No 66404.
S&F Modular bell push, 10 Amp, AC 230 Volt etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVSBIW101 or equivalent of Legrand/Siemens/Schenider.
S&F for Bell Ding Dong AC 230 Volt, single Pole complete all as specified and directed. Make : Anchor Cat Part No 8024 or equivalent model in Havells/ SSK
S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 65 x 50 mm, three terminals, AC 230 volts etc, complete all as specified and directed. Make : Havells Cat Part No Reo/Cona Cat Part No 9246/GM Cat Part No 8224
S&F Lamp holder insulated body with back plate suitable for batten fitting and including with 14 watt LED lamp complete all as specifeid and directed. Make : Havells Cat Part No Reo/Cona Cat Part No 9196/GM Cat Part No 8220, 8221.
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed. Make : Legrand Cat Part No 673028/Crabtree Cat Part No ACARFHW005/Anchor Roma Cat Part No 66502.
M &L for ceiling fan 1200 mm sweep with down rod & all accesseroies with & incl modular type fan regulator socket type 120 watt complete all as specified and directed.
M &L for fresh air fan 200 mm sweep with all accesseroies fixed to wall with proper size of nuts bolts complete all as specified and directed.
S&F in Heavy duty Exhaust fan, single phase, 220 Volts, 50 Hz, 1400RPM, 300mm sweep with louvers including cutting round opening, through one brick thick masonry wall suitable for exhaust fan by providing, fixing and removing shoring, forming jambs with CM 1:3 and making good disturbed surface to match existing finish and removal of rubbish out off the premises etc complete all as specified and directed. Make : Crompton Model No EXHD300-4-1 or equivalent model of Bajaj/Havells
Supply, installation, commissioning and testing of storage water Heater, 25 Ltr capacity 5 Star rated BEE certified, vertical type, ABS body, external thermostat, Single phase 220 volt, 50 Hz including Plug Top, incl 02 Nos 15 x 60 mm PTMT PVC connection for Hot & Cold water pipe line and necessary mounting arrangement by grouting split bolts of size 12mm dia and not less than 100mm long etc complete all as specified and directed. Make : Havells Model No Puro Plus/Bajaj Model No Calents/Crompton Model No Solarium DLX.
S&F Decorative ultra slim liner LED Lighting fixture with extruded polycarbonate envirmental friendly, energy efficient tube light fitting including complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5Sqmm with suitable size of 20Watt complete all as specified and directed .
S & F the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed. Notes for Srl item No 129 & 130 :- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair
S & F for sheet metal enclosure double door for distribution board (When MCB's are to be used) triple pole and neutral 415 Volts 4 way with 200 Amp rated busbar complete all as specified and directed. Make : Legrand/Schneider/Hager
S & F for sheet metal enclosure (Factory made) double door for distribution board (When MCB's are to be used) single pole and neutral 240 Volts 8 way with 200 Amp rated busbar complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F for MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (B-series) , complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F for MCB single pole (SP) 240 volts, 63 Amps, 10KA (B-series) , complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F Single pole & neutral enclosure with a two pin & earth plug & socket complete with one single pole MCB 20 Amps 240 volts (B-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
S &F RCCB Single pole & neutral 240 Volts, 40 Amps and sensitivity 30mH, with breaking capacity of 10KA complete all as specified and directed. Make : Legrand/Schneider/Hager
S &F MCB triple pole & neutral 415 Volts, 63 Amps with breaking capacity of 10KA complete all as specified and directed. Make : Legrand/Schneider/Hager
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X6 sqmm multistranded copper conductor cable 1100 V with 1X6 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring complete all as specified and directed. (Note: Two runs of FRLS PVC cable with one run of earth conductor and one run of conduit shall be measured as one RM.) Make or wire : Polycab/Anchor/Finolex
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X10 sqmm multistranded copper conductor cable 1100 V with 1X10 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 25 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring complete all as specified and directed. (Note: Two runs of FRLS PVC cable with one run of earth conductor and one run of conduit shall be measured as one RM.) Make or wire : Polycab/Anchor/Finolex
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 25 sqmm 4 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable & bricks complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
SIDDAHANT ENTERPRISES
BALI ENTERPRISES
s k construction co
M/S NAGAR BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .