| 1 | L1₹11.6 LAccepted-AOC 1008 LASKARHAT FLAT 2A 2ND FLOOR KOLKATA 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.6 L+₹2.1 L (17.9%)Rejected-Finance | L2 | Rejected-Finance 1364567.57 | |
| 3 | L3₹14.0 L+₹2.5 L (21.3%)Rejected-Finance 133 GARFA MAIN ROAD KOLKATA 700 078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L3 | Rejected-Finance 1403689.42 | |
| 4 | L4₹14.5 L+₹3.0 L (25.6%)Rejected-Finance DHARSHA NEAR MATH P O GOVT OF INDIA PRESS COLONY DIST HOWRAH PIN 711 112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L4 | Rejected-Finance 1453335.00 | |
| 5 | L5₹14.8 L+₹3.2 L (27.7%)Rejected-Finance | L5 | Rejected-Finance 1477459.31 |
Tender Value
₹17.6 L
EMD Value
₹35,170
Closing Date
18 Feb 2021, 2:00 pmClosed
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Internal Electrification Works for 3rd Floor at Bikalpa Shakti Bhawan OF WBREDA Salt Lake Sector V Kolkata 700091
2021_WBPWD_321924_1
WBPWD/EE/BED/31/e-IT of 2020_21
Open Tender
ELECTRICAL WORKS M/R
Item Rate
45 days
Biklpa Shakti Bhavan
Please refer Tender documents.
5 documents required · 5 mandatory
₹35,170
Yes
8 Mar 2021
1 Feb 2021
22 Feb 2021
5 Feb 2021
18 Feb 2021
5 Feb 2021
Amount
Part -A S&F 4 way Vertical TPN PBDB with 3 phase in coming & TP/SP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43 protection) double door comprising of neutral link incl. & provision for earthing attachment concealed in wall after cutting the brick wall and mending good the damages to original finish incl. interconnection with suitable size of copper wires and earthing attachment. (For 3rd Floor Load) Incoming-415V, 25/35KA, 125A, FP - MCCB----1no Outgoing- 415V, 10KA, 63A T.P MCB C Curve,.----4 nos Make-( Legrand/Siemens/Crabtree)
Supplying and fixing 415 V, 16-32A per way, TPN MCBDB with SS enclosure double-door with IP-42/43 protection with Four Pole MCB as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS. ( Make - Legrand / Siemens / Schneider). a) 6 Way HTPN Incommer 415V 10KA 100 A 4 pole MCB - 1 No, Outgoing 16A- 32A SP MCB - 18 Nos
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. ( Make - Legrand / Siemens / Schneider). a) 2 + 10 Way SPNDB Incommer 230V 10KA 40A DP MCB - 1 No, Outgoing 6A- 32A SP MCB - 10 Nos
Supply & laying XLPE/PVC Al Ar. cable as below conceled in wall with 2 nos 10SWG GI (hot dip) wire by GI Saddle making hole & mending good the damages as to GS as follows : - (Make: KEI/Ploycab/Havells) a) 3.5 core 95sq mm PVC / A cable (from Floor panel to VTPNs)
b) 4 core 25 Sq mm PVC / A cable (from HTPN DB to AC OUTDOOR)
c) 3.5core 35 sq mm PVC / A cable (from VTPN to HTPN DB)
S & F compression type moisture proof brass cable gland & finishing end of the cable end by soldering / crimping method with cable socket & insulated tape as to GS as follows: a) 3.5 core 95sq mm PVC / A cable
b) 4 core 35sq mm PVC / A cable
c) 4 core 25sq mm PVC / A cable
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/Havells/Ploycab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (a) Average run 10 Mtr.
b) Average run 9 Mtr.
c) Average run 8 Mtr.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in mainly 19/25mm dia 3 mm thick polythene pipe complite with all accessories etc. embedded in wall etc. (Approved Make) a) 3X1.5sq mm (for 5 amp seperate plug point)
b) 2 x6 sq mm + 1 x 4 sq mm (SPN DB to TPN DB)
c)2X2.5 sq mm + 1X 1.5 sq mm (Separate 15 amp plug point & computer board)
Supply & Fixing 250volt of moduler type (12 module) plug socket computer board of comprising of folllowing accessories. a) 6/16A switch & socket-------1 set b) 6A-------do------(--do--)----------2set c) Indicator----------------------------1set incl. Necessary interconnection by pvc insulated copper wire fluhed in wall. (Make: Legrand/Crabtree/ABB)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make: Legrand/Crabtree/ABB) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(for Power Plug)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as followes (i) 2 x 2.5 sq mm + 1 x 1.5 sq mm
(ii) 2 x 6 sq mm + 1 x 4 sq mm
S & F the exhaust fan after cutting wall & manding good the damages to original finish incl. S & F GI louver shutter as followes.(Make: EPC/USHA/C.G)12" dia exhaust fan
S & F 400 mm sweep wall mounting bracket fan on HW board as per direction of EIC (Orient-Wall 41/Usha/Crompton)
Supply & Fixing (2'X2') LED fittings with necessary accssorries and connection. ( Phillips SmartGlow, Cat No- RC370B LED/Wipro/ Crompton)
Supplying & Fixing wireless type electronics Call Bell (Approved by EIC) on HW board.
S&F 12-Watt 6''x6'' Recessed LED Ceiling Light ( White,Round) mounted on false ceiling with necy. Connection. (Make-Philips, Ultra Slim Plus 12-Watt Recessed LED/ Wipro/ Crompton)
Supply & Fixing 7W Spot LED fittings with necessary accssorries and connection-- (Phillips Green LED, cat no- Philips GreenSpot/ Wipro/ Crompton)
Supply & Fixing 5mtr. LED Strip (Colour choose by EIC) with Driver with necessary accssorries and connection-- (Cat no- Philips LED Strip / Wipro/ Crompton)
Supply & Fixing 6 L Instant Water Geyser on wall incl. neccesary accessories. (Make-Racold, cat no.- Pronto Neo SS/Havells/Crompton)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the groundlevel as below: (a) By TATA-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming. (b) For Soft Soil
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
SATABDI ENGINEERING COMPANY
Prava Enterprise
ULTRA ELECTRICALS AND ELECTRONICS
T. K. ENTERPRISE
A.B. ENGINEERING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .