Loading…
Loading…
Tender Value
₹49,843
EMD Value
₹1,246
Closing Date
11 Jun 2026, 4:30 pm5d left
Assistant Engineer
Office of the Assistant Executive Engineer, LIDEW Subdivision, Konni block Panchayat
Konni BP-Pr.No.S0198/26-Providing basic infrastructure for Vanitha Gym in Vallikode FHC-General Electrical Work
2026_LSGD_854225_1
02/2026-27/AE/LSGD/KNI
Open Tender
Electrical Works
300 days
Elakollur
Please refer Tender documents.
7 documents required · 7 mandatory
₹335
Yes
₹1,246
Yes
4 Jun 2026
4 Jun 2026
15 Jun 2026
4 Jun 2026
11 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1ELECTRIFICATION | ||||||
| 1.001 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | - | point | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | - | point | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | - | each | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | OD5322/2026-2027:Supply and fixing of 400mm sweep metal wall fan (Make: Havells or equivalent) | - | each | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | OD5323/2026-2027:Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with
200mm polished shade with 9W LED and giving connection etc as required | - | each | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | OD9323/2026-2027:Supply and fixing cast aluminium stove enameled bulk head fitting with deep
drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic
glass cover with 9 W LED to wall / ceiling including giving connections with
required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round
copper conductor fle x wire conforming to relevant ISS or extending the original
wiring and making good the surface as required.(Mepro /Philips/Crompton/Bajaj
make) | - | each | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | - | metre | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | - | metre | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Epay.pdf
Tender Documents • 0.23 MB
affidavit.pdf
Tender Documents • 0.24 MB
Ipact.pdf
Tender Documents • 0.23 MB
Pagreement.pdf
Tender Documents • 0.25 MB
FOT.pdf
Tender Documents • 0.25 MB
BOQ_1443755.xls
BOQ • 0.31 MB
Merged.pdf
Tender Documents • 1.68 MB
Download all tender documents and submit your bid