| 1 | L1₹54.6 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC AOC accepted | |
| 2 | L2₹59.1 L+₹4.4 L (8.09%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-AOC AOC rejected | |
| 3 | L3₹63.1 L+₹8.4 L (15.4%)Rejected-AOC 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L3 | Rejected-AOC AOC rejected |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
22 Aug 2023, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair and replacement of Over Head Line, Cables, VCBs, Panels, Transformers and connected items at Garhi Cantt Area under AGE E/M-II of GE Dehradun.
2023_MES_610650_1
8658/A/E8
Open Tender
Civil Works
Item Rate
334 days
GE Dehradun
Class D cat b (ii)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹98,000
Yes
30 Sept 2023
25 Jul 2023
24 Aug 2023
25 Jul 2023
22 Aug 2023
8 Aug 2023
Amount
Material and labour for spraying of agricultural based chemical inside the installation to control the growth of unwanted herb, shrubs etc including cutting, removing the vegetation growth & surface dressing all around the installation yard/ transformer /LT panel Board area external only to keep installation always clean and tidy condition complete all as specified and directed. Note:- All the installation yards/area shall be kept clean throughout contract period by repeatedly removing the grass / shrubs as many times required depending on the growth of grass measurement will be measured & paid only once throughout contract period complete all as specified and directed.
Material and labour for attending fault/ breakdown in Over Head line /Breaking UG Cable due to any reason like falling of tree branches, Bird hits, Cracking of Pin/ Disc insulator, breaking Over Head conductor complete including patrolling of LT line, Meggering, removing of fault, replacement of insulator any type, replacement of fuses and restoring the feeder complete all as specified and directed for following areas :- Notes : (i) All T&P & Man Power required to complete job is included in unit rate. (ii) Unit rates also included the conveyance & communication facilities required to complete the job.
MH feeder (Approximate 8 KM go and back )
New Cantt feeder (Approximate 12 KM go and back )
Upper Camp feeder (Approximate 10 KM go and back )
Mall Road feeder (Approximate 6 KM go and back )
RIMC feeder (Approximate 5KM go and back )
Birpur feeder (Approximate 9 KM go and back upto Bijapur PH )
Ganghora feeder (Approximate 3 KM go and back upto Seven Oak school)
Supply and fix station class type lightning arrestor suitable for 33 KV discharge current 65 KA fixed on existing steel structure including connection with earth strip conforming IS 3070 (Part -3) 1983 Class 'A' complete all as specified and directed including taking down existing old unserviceable complete all as specified and as directed by Engrz-im-Charge.
Material and labour for lightning arresters silicone rubber type 12 KV grade complete with all fittings, station class, discharge capacity 65 Kilo Amps complete all as specified and as directed including taking down old unserviceable lightning arresters complete all as specified and as directed by Engr-in-Charge.
Supply and fix of Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 33000 volt grade complete all as directed including disconnection and taking down existing lightning arrestor complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of old unserviceable HT studs of transformer any type or size including taking out transformer oil opening up of top lid and replacement of unserviceable studs including top up of oil replacement of gasket etc and making transformer leak proof complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of old unserviceable LT studs of transformer any type or size including taking out transformer oil opening up of top lid and replacement of unserviceable studs including top up of oil replacement of gasket etc and making transformer leak proof complete all as specified and directed.
Material and labour for servicing 33 KV yard structure complete including replacement unserviceable jumper, sleeves vice type conductor, bolt nut and washers connecting lugs / thimble knife contact, applying petroleum jelly to the moving as well as fixed contacts tightening all the connection for its smooth functioning preparing old painted surface of this structure such as poles, cross arms, bracing supports, clamp and back plate complete painting of two coats of anti corrosive weather proof heat resistant aluminium paints over a coat of red oxide zinc chrome primer and providing Red/Yellow and Black paint including writing SM/MES NO or all other direction/marker/code etc. with grey/black paint on boards etc. not less then 40mm height & 10mm thick complete all as specified and as directed by Engr-in-Charg. Note: No extra payment will made for the spares required to keep the yard structure in satisfactory functional throughout contract period other than given in schedule for 0nce in 3 month.
Supply and fix in replacement 33kv Substation Tube Busbar with Clamping N Connector N Insulator , Solid, Overhead, Aluminum, as per ISO 9001 the tube aliminum alloy 6063 tube busbar of suitable size from 70 to 300, with suitable current carrying capacity of the conductor is from 630Amp to 6300Amp with complete set of clamping of tube busbar supporting insulator and T connector complete all as specified and as directed by Engr-in-Charge.
Supplying in replacement of existing unserviceable control cable including laying or fixing with saddles or cable tie etc, jointing and testing LT PVC insulated copper conductor armoured electric power cable ISI marked with multi stranded copper conductor heavy duty 1100 volts grade of 2.5 Sq mm 4 core complete all as specified and directed.
All as per item No 10 here -in-before but 2.5 Sqmm 6 core complete all as specified and directed.
Supply & filling the new transformer oil of rupturing capacity 50KV for 60 Sec for topping up to required level of transformer complete all as specified and directed.
Supply and fix transformer breathers transparent of standard size suitable for 5 MVA transformers 33/11 KV volts cast alluminium transparent type including removing the existing unserviceable one complete all as specified and directed.
Material and labour Filtration/dehydration of the existing transformer oil at site of any make of transformer and capacity up to required dielectric strength as per IE rules and refilling in the transformer up to required level complete all as specified and directed. (The dielectric strength shalld not be less than 50 KV after filtration process)
Taking out of HT cable 95 to185 Sqmm 3 core of any size from ground or poles etc and testing for serviceability and kept aside for reuse including proper rolling, loading unloading, transportation etc complete all as specified and directed. Note:- Earth work for the same shall be measured and paid separately.
Laying only of existing serviceable cable 95 to185 Sqmm 3 core in ground retrieved against item No 15 here -in-before complete including unrolling, unloading, transportation etc testing connections complete all as specified and a directed by Engr-in-Charge.
Material and labour for under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade copper sheet wrapped cross sectional area 95 Sqmm 3 core including taking down of old unserviceable cable complete all as specified and directed.
All as per above item No 17 here-in-before but 11000 Volts 120 Square metrem 3 core complete all as specified and directed.
All as per above item No 17 here-in-before but 11000 Volts 185 Square metrem 3 core complete all as specified and directed.
Material and labour for cable end jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 Sqmm including testing after jointing complete all as specified & directed.
All as per Item No 20 here-in-before but 11 KV 240 to 300 Sqmm
Material and labour for cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 Square metrem including testing after jointing complete all as specified & directed.
Material and labour for straight through cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 Sqmm including testing after jointing complete all as specified & directed.
Material and labour for transformer cable boxes or LT panel board cover/ panel doors etc made out of 3.0 mm CRCA sheet duly powder coated complete to make the system safe and secure complete including making hole nut bolts washer etc all as per site requirement complete all as specified and directed.
Dismantling and taking out old unserviceable cross arms and Material and labour for cross arms, bracing, supports clamps back plates, gantry bay structure etc fabricated from structural steel section such as suitable I section channel ISMC angle iron and flat iron GI nut, bolt & Washers with welding, cutting, drilling hole etc for insulator bolts clamps in any shape and size including one coat of red oxide and two coats of epoxy heat resistant paint all complete all as specified and directed.
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete shifting cost etc. and removing the old unserviceable rubbish etc complete all as specified and directed.
Fixing only of steel poles of any length and dia retrieved against respective item of demolition / dismantling including loading, shifting unloading erection in true vertical position complete all as specified and directed. Note - Excavation and PCC shall be measured and paid separately.
Supply and fix disc type insulator (single disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
Supply and fix Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
Taking down of GOD vertical/Horizantal mounted including insulator and opening mechanism for servicing repair or replacement to existing GOD switch with DO fuse of any size complete all as specified and directed.
Material and labour for switch Air break gang operated triple pole out door type 11 KV 50 cycle AC(GOD) suitable for current rating upto 200 Amps mechanically operated mounted on silicon rubber insulators (12 insulators) and frame with operating mechanism from ground level with earth switch and including locking arrangement complete all as directed.
Material and labour for fixing only of existing GOD any type or size after repair incl replacement of blades bushings etc complete all as specified and directed.
Material and labour for Trimming/ pruning of tree branches up to 5 meters above & below and both sides to obtain clearance all around the LT over head lines / HT over head lines conductor upto 5 mtr from farthest conductor between Each adjuscent Pole including removing of cut branches and cleaning of site complete all as specified and directed.
Material and labour for painting to existing 4 pole structure including pole, cross arm, bracing clamps, GO DO fuse etc with two coat of heat resistance aluminium paint above coping complete all as specified and directed.
Material and labour for painting to steel pole including pole, cross arm, bracing clamps, etc with two coat of heat resistance aluminium paint above coping complete all as specified and directed.
All as per item No 35 here -in-before but 2 pole structure complete all as specified and directed.
Material and labour Complete servicing/overhauling of On Load Tap Changer & replacement of burnt / damaged wiring, complete all as specified and directed.
Dismatling of Transformer of any size/capacity from 2/4 Pole structure, duly disconnecting exisiting cable carefully and re-connect after the mounting to the PCC foundation and HT Poles and accessories should be deposited to MES store for re - installation complete all as specified and directed.
Material and labour for Loose filling with aggregates of gauge 40 to 80 mm in surrounding of Transformer permisses all specified and directed by Engr-in-Charge
Material and labour disconnecting and taking out old unserviceable damaged/burn out cable of any size & make and supplying, laying, jointing and testing LT underground cable, heavy duty cable of size 10 Sqmm 4 Core, 1100 Volts, XLPE insulated and PVC sheathed, armoured, multi-stranded aluminium conductor cable conforming to IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable including cable gland and lugs etc at both ends incl disconnecting and taking out unserviceable damaged cable complete all as specified and directed. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
All as per item No 40 here -in- before but 16 Sq mm,4 core complete all as specified and directed.
All as per item No 40 here -in- before but 25 Sq mm, 4 core complete all as specified and directed.
All as per item No 40 here -in- before but 50 Sq mm, 3.5 core complete all as specified and directed.
All as per item No 40 here -in- before but 95 Sqmm 3.5Core complete all as specified and directed.
All as per item No 40 here -in- before but 185 Sqmm 3.5Core complete all as specified and directed.
All as per item No 40 here -in- before but 300 Sqmm 3.5Core complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed.
Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed by Engr-In-Charge.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete all as specified and directed.
Material and labour for laying reinforced precast concrete cable cover (For HT Cable Only), Class LV, Type I, flat, size 250 mm x 150mm x 40mm to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Laying retirved PCC cover retrieved during the excavation for the replacement of fault cable (For HT Cable Only), laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Cutting existing road/hardstanding of any type by using crow bar chisel upto a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 4Pole,, 400 Amps, 36 KA, 415 V , with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as specified and directed.
All as per item No 55 here in above but MCCB 4Pole, 320 Amps, 36 KA, 415 V complete all as specified and directed.
All as per item No 55 here in above but, 250 Amps, 36 KA, 415 V , complete all as specified and directed.
All as per item No 55 here in above but MCCB 4Pole, 200 Amps, 25 KA, 415 V complete all as specified and directed.
All as per item No 55 here in above but MCCB 4Pole, 160 Amps, 25 KA, 415 V complete all as specified and directed.
All as per item No 55 here in above but MCCB 4 Pole, 125 Amps, 25 KA, 415 V complete all as specified and directed.
All as per item No 55 here in above but MCCB 4 Pole, 100 Amps, 25 KA, 415 V complete all as specified and directed.
All as per item No 55 here in above but MCCB 4Pole, 63 Amps, 25 KA, 415 V complete all as specified and directed.
Supply and lay in trenches fixed to poles wall laid in floor GI steel tubing medium grade of following bore including fitting bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed incl disconnection and taking down existing tubing complete.
80mm bore (dia)
40mm bore (dia)
Taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creapers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles including takingout fixing site complete all as specified and directed . Note: (i) If any major repair is required, attending complaints and replacement of any nature in LT Power network at any point and time, the items shall be replaced with respective item of sch 'A' is deemed to be inclusive (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk.(iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate before the commencment of work. (v) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engr-in Charge as day to day basis .
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core 240 to 300 Sqmm including taking down of old existing joint complete all as specified and as directed.
All as per item No 67 here in above but cable jointing kit of size 150 to 185 Sqmm complete all as specified and directed.
All as per item No 67 here in above but cable jointing kit of size 70 to 120 Sqmm complete all as specified and directed.
All as per item No 67 here in above but cable jointing kit of size 25 to 50 Sqmm complete all as specified and directed.
All as per item No 67 here in above but cable jointing kit of size 6 to 16 Sqmm complete all as specified and directed.
Supply and fix in replacement LED indication Lamps (RYB) complete all as specified and directed.
Material and labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm connected to galvanized iron strip 25x4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
All as per item No 74 here-in-above but earthing with GI Srip of sixe 32x 6mm, complete all as specified & directed by Engr-in-Charge.
Supply and fix insulator pin type porcelain vitreous white, brown or green LT 1100 Volt including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised. iron nut of size 100mmx65mm all as specified and directed by E-in-charge including disconnection and taking down existing insulator complete all as specified and directed.
Supply and fix shackle type insulator porcelain vitreous LT 1100 Volt 100x115mm including G.I. mild steel strip at 31 x 6 mm 12mm dia insulator bolts, washers, nuts suitable for working pressure 1.1KV including disconnection and taking down existing insulator complete all as specified and directed.
Supply and fix of oval shape min 65 mm dia or higher size cable route indicators HT or LT made out of cast iron and fixed on 25 mm equal angle of 45 cm long complete including grouting the same in PCC complete all as specified and directed.
Material and labour for shifting of LT Panel/Bus Bar Chamber/Feeder Piller from the foundation duly disconnectig existing inoming/out going connection carefully (any capacity ,any type) and re-installed where ever directed by Engr-in-Charge, duly necessary connection and PCC foundation and earth work etc complete all as specified and directed
Taking down/dismantling LT Panel/Bus Bar Chamber/Feeder Piller from the foundation duly disconnectig existing inoming/out going connection carefully (any capacity ,any type) for caryout repair all as specified and directed.
Supply and fix Rolled mild steel sections as in framing for panel board , stand, cladding, glazing and the like fixed with angle cleats and connecting plates, etc. and fixing conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
Material and labour for fabricating MS CRCA sheet of 3mm thick, the inner shell duly compartmented for each control gear, including Powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements welded with exisiting panel complet all as specified.
Material and labour for fabricating and fixing alluminium bus bars of exisiting gauge/size duly connected with existing incoming/outgoing connections complete all as specified and directed.
Supply and fix Cable glands of exisiting gauge/size duly connected with existing incoming/outgoing connections complete all as specified and directed.
Material and labour for painting of LT Panel/Bus Bar Chamber/Feeder Pillar box of any type & size. Removing old paint with emery paper/wire brush, fill the cavilties with metallic putty and made smoth surface, apply one caot of allumiium paint over a coat of metallic primer surface complete all as specified and directed.
Material and labour for installation of CCTV camera with DVR + 8 Camera, UPS LED TV32 "(Samsung/LG), with software connected with Mobile application including LED TV 32" (Samsung/LG) ,UPS, including wifi connection all complete all as specified. Note :- (i) One time ,1 year wifi subscription to be paid by the contractor. (ii) The contractor should install the CCTV and all coneected job within 15 days from the date of commencement.
Supply and fix in replacement of SCADA compatible Outdoor Type Marshalling Box (suitable for 5 MVA 33/11KV OLTC Transformer) having OTI, WTI, TTB, Heater, Lamp, Door Switch & Control MCB. Control wiring from Marshalling Box to VCB will be done by contractor including supplying & laying of control cable of 2.5 sq. mm size complete all as specified and directed.
Supply,Installation,Testing and commiossioning 40 kA 1 phase 3 wire Portable Digital Grounding Device which provides Low Impedance to all theequipments also Grounding & bonding system with built in 100% Lightning and Surges suppressor, static charge, Noise, ESD, EPR and abnormal electrical characteristics eliminator which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V, self health visual status indicator in a Pre-wired pulverulent body painted metal enclosure, to be connected in parallel to the in - put power supply circuit, Conforming to IEC , ISO 9000 & ISO 14001-2015 certified with all accessories. Model: DSS-MII-1P3-40 complete all as specified and directed.
Material and labour for fault detection in UG HT cable of any size or type at any depth with fault locator including material T&P required for the same and testing complete all as specified and directed. Note 1- Joint, excavation laying only of cable shall be measured and paid separately. 2. Each fault shall be treated as one job and contractor have to address the said fault immediately.
Material and labour for excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and directed.
Material and labour for cement concrete type C2 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Supply and fix for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only Chainlink MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Material and labour for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth including two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 complete all as specified and as directed.
Material and labour for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4), finished surfaces even and smooth complete all as specified and as directed.
Material and labour for preparation of new surfaces of walls and applying two coats of cement base paint over suitable primer complete all as specified and as directed.
Taking out transformer from its position from location under GE Dehradun for repair/ servicing/ rewinding of following capacity with OLTC, 11/.415KV ,disconnecting/ opening HV, LV electrical, earthing connections
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Transporation of transformer to authorized workshop (UPCL autorised company) by making necessary arrangements of T&P (crane, recovery, vehicle etc.) for the following capacities.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Material and labour for Opening of transformer top cover by extraction, removing of serviceable/ unserviceable nuts bolts and washers etc . Note : Contractor should carried Pre-inspection of transformer at the Company and obtain necessary photos and certificate of Coil cutting from the company duty signed by Inspecting officer and Forman/Engr-in-charge of the Company.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Material and labour for Draining out of transformer oil complete all as specified and directed.
Material and labour Lifting primary (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully & display all the parts without damaging any portion for inspection.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Material and labour labour transformer winding including taking out and testing for serviceability and rewinding the same with fresh copper wire or strip including insulation paper bobins etc and keeping the same into the hot air oven till the moisture will remove and insultating resisitance improves to the satisfaction level, refixing the same in original position all as specified and directed by Engr-in-Charge (Old copper scrap will be retained by contractor, rate to quote for
Material and labour for Replacement of Press Board & Insulation complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Material and labour for Replacement of Gasket & washer complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Material and labour for Replacement of Silica Gel Breather (Main Tank + OLTC Tank) complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Material and labour for Complete overhauling of On Load Tap Changer (OLTC) and including replacement of wiring cunductors, connectores including wiring of control cable connections and connection , all specified and directed
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Replace ment of HV & LV Termination complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Replacement of sundry items like Tapes, Sleeves, Bakellite, Nut & Bolts wherever required complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Heating, Drying & Meggar Improvement complete all as specified and directed.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Reassembling the transformer complete with all existing serviceable parts and new parts as per requirement i.e. Repair labour charges
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
Return back from OEM Workshop with Placement of transformer to its position at location under GE Dehradun after repair/ servicing/ rewinding of capacity 11/0.433 KV Reconnecting HV, LV electrical connections, earthing connections along with following other works like checking & testing of HT line / HT Cable, HT Switchgear etc. Note:- (a) All routine tests will be carried out at manufacturer works (b) Transformer will have warranty period of 6 months from the date of re-fixing at site. (c) UPCL authorised delaers/representative should be available at the time of commissioning of transformer. (d) Any other work required to carryout above job in inclusive.
100 to 200 KVA
250 to 400 KVA
500 to 630 KVA
JS CONSTRUCTION COMPANY
u and v engineers and consultants
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .