Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹7.3 Laccepted-aoc | accepted-aoc |
Tender Value
₹9.1 L
EMD Value
₹10,000
Closing Date
25 Sept 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Office of Superintending Engineer, Mission Bhagiratha, Circle Sangareddy Opp ZPP Sangareddy 502001
Operation and Mainteneance for Sub Stations/ transformer yards for Sangareddy Segment
732441
No.01/AEE2/26-27, Dt:09.09.2026
OPEN
Electrical Works
SANGAREDDY, TELANGANA
14 documents required · 14 mandatory
₹322
₹10,000
9 Nov 2026
11 Sept 2026
11 Sept 2026
90 days
Essential Items Total: PART-I (For the period 01.10.2026 to 31.03.2027), 6 months Man Power Engaging of ITI qualified Electrician with 5 years experince in substations from 01.10.2026 to 31.03.2026 (182 Days) for 33/11KV sub stations and 11KV transformer yards. 33/11KV substation at 100MLD Busareddypally
Engaging of ITI qualified Electrician with 5 years experince in substations from 01.10.2026 to 31.03.2026 (182 Days) for 11KV sub stations and 11KV transformer yards. At Raghavapur WTP & intake well & IPS Thammadapally, pasthapur,pamphad 10mld WTP
Work of repairs/servicing and overhauling of on load tap changer (OLTC) of upto 33KV/11KV 8MVA transformer as specified below: Painting of transformer including platform CTS etc., with one cost of red oxide to the rusted portion of transformer, 2 coats of M/s grey enamel paint, RYB color paint to CT caps for identification etc., Rates should quote inclusive of cleaning of the transformer of all sizes. 33/11KV substation at Busareddypally
Carryout routine maintenance, servicing and testing of 630A to 3000A (33KV/11KV) HT VCB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the VCB in perfect working condition after detting all relay and ON, OFF mechanism etc done with only manufacturing companies / Authorised dealers of respective switch gears every 6 months @ 2*12401.08 = 24802.15 33/11KV substation at 100MLD Busareddypally
Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). 800KVA DTR locations: Busareddypalli Intakewell-800KVA DTR Sl.No. 2207933 Toshiba make and 800KVA 2207919 Toshiba make.-2 No.s 630KVA DTR locations: Raghavapur IPS-DTR,630KVA, I no.Make:ESENAR Transformers(P) Ltd Sl.No.ET2-l244 500KVA DTR locations: Raghavapur IPS-DTR,630KVA, I no.Make:ESENAR Transformers(P) Ltd Sl.No.ET2-l244 Pampahad-1No. Thammadpally -TSSPDCLDTR,500KYA,2no's.Make:KRKPower Pvt.LtdSl.No.1285,1360 Aliabad-TSSPDCLDTR,500KVA,1 nos.Make:KRKPowerPvt.LtdSl.No.1359 160KVA DTR locations: Kavelly-TSSPDCL DTR, 160KVA, I no.Make:KRK Power Pvt.LtdSl.No.334 250KVA DTR locations: Pastapur-TSSPDCL DTR, 250KVA, I no. Mahabathpur-250KVA 160 KVA DTR locations: Tallapally intake well -TSSPDCL DTR Tallapally -TSSPDCL DTR, 63 KVA DTR locations: koheeer -TSSPDCL DTR, 63KVA, Hugelli -TSSPDCL DTR, 63KVA 100 KVA DTR locations: Nallampally -TSSPDCL DTR, 100KVA, Indrasham -TSSPDCL DTR, 100KVA,
Attending day to day emergencies(Sub-station check up & maintenance Day to day Protection related emergency works attending and maintenance works of various 33/11KV Substations including Initial assessing the exact faults in the protective device in the VCBs & other protective devices to take up the further works, Rectification/ Replacement of AC/DC fuses, Selector switches, TnC Switches, Push buttons, Hooters, bells, TBs, Ammeters, voltmeters, MW/ KW meters, MVA/ KVA meters, Indication lamps, MVAR/ KVAR meters, PF meters, Panel type energy meters, Terminals, Trip Coils, Close Coils, Spring Charging motors, Relays, Big Gears,Pinion gears, Small gears, 12 V Batteries, 2V Batteries, 24v Chargers, damaged/ defective wiring, etc , measurement of earth resistance, Breaker Operation time (O-CCO) with Breaker timer kits, checking for continuity/ interconnections between earth pits & equipments with primary injection kits, insulation resistance of CTs, PTs, Breakers with Insulation resistance measurement tester (megger), Ratio of CTs with primary injection kits, Tightening of all connections inside the breaker panel, Control Panel, CR Panel, Control Circuit, Battery chargers, battery connections, PTR marshalling boxes, Wiring of CTs and PTs when defective CTs and PTs replaced with new one, Restoration of PT supply to the panel when it fails, Balancing of capacitor bank when cells failed, Fixing up of desired relay settings for feeder, LV, HV, GC breakers, Checking up of VCB mechanical spring charging problem, Checking up of trip circuit healthy of CBs, AC Supply restoration to the breaker when fails, 220V DC supply extension to the VCBs, 24V DC battery chargers connections extension to the VCB when the existing charger fails, Minor alignment of breaker for CB operations, Snatch gap adjustment of breaker to take CB in to service, Identification and rectification of wiring problem of breaker, DC system, AC system for protective equipment, Rectification of mechanical/ slow closing problem of CB where material is not required for the work, Attending the Minor mechanical problems of CBs (Closing / tripping may be electrical or mechanical), Testing of new VCBs (Primary injection, IR values, DC resistance, etc), attending & rectification of oil leakages problems of CTs & PTs, Oil topup in CTs & PTs wherever required, Replacements of Clamps, jumpers, studs, bush rods, bolts & nuts, gaskets, connections of CTs & PTs and other protection related works entrusted by the concerned Engineer for every month
Testing of static/electro mechanical Relay elements for proper operation including recording of all name plate details of Relays & Circuit Breakers, recording of existing relay settings, testing of each element of relay with calibrated relay test kit, recording of re;ay test results in systematic procedure, adjusting & fixing up of time settings of relays wherever required for proper functioning, fixing up of relay settings & grading as per department requirement, recording of revised relay settings of wherever revised, testing of relays by conducting primary injection to the CTs, verification & correcting of connections from CTs to Relays wherever required for proper functioning, carrying out minor rectifications, Measurement & recording of Insulation Resistance values of Current Transformers & Circuit Breakers & connected equipment with suitable calibrated Insulation Measurement Tester, recording of all test results in a systematic way & submission to the department in five copies, execution of work by qualified & experienced persons with contractor owned/ hired calibrated suitable testing equipment as per standards in presence of the concerned AE/ DEE/ EE by proper advance planning, intimation & coordination with the concerned officials, etc for completion of work within schedule time for proper operation of equipment and the rate is inclusive of testing charges transport, loading, unloading, local movement, hire charges, calibration charges, insurance to the working persons, etc complete.
Testing of IED Relay complete all required elements for proper operation including recording of all name plate details of Relays & Circuit Breakers, recording of existing relay settings, testing of each element of relay with calibrated relay test kit, recording of relay test results in systematic procedure, adjusting & fixing up of time settings of relays wherever required for proper functioning, fixing up of relay settings & grading as per department requirement, recording of revised relay settings of wherever revised, testing of relays by conducting primary injection to the CTs, verification & correcting of connections from CTs to Relays wherever required for proper functioning, carrying out minor rectifications, Measurement & recording of Insulation Resistance values of Current Transformers & Circuit Breakers & connected equipment with suitable calibrated Insulation Measurement Tester, recording of all test results in a systematic way & submission to the department in five copies, execution of work by qualified & experienced persons with contractor owned/ hired calibrated suitable testing equipment as per standards in presence of the concerned AE/ DEE/ EE by proper advance planning, intimation & coordination with the concerned officials, etc for completion of work within schedule time for proper operation of equipment and the rate is inclusive of testing charges transport, loading, unloading, local movement, hire charges, calibration charges, insurance to the working persons, etc complete.
Attending day to day emergency works Day to day Power Transformers related emergency works attending and maintenance works of various 33/11KV Substations including initial identification of the defects of PTR on complaints from field to take up the further works, General Checkup of PTRs for healthiness, Attending of minor Oil Leakage complaints, Toping up of oil to the Main & OLTC conservator tanks, Attending the Low Oil Complaints, etc all complaints, Carrying of periodical maintenance of PTRs, Conducting tests periodically as per the norms, Preventive, Breakdown, Predictive & proactive maintenance of PTRs, Conducting pre-Commissioning & Commissioning tests for new & repaired transformers, Replacement of Oil Seals, Silicagel, breathers, Oil cups, PTR Clamps, WTIs, OTIs, PRVs, MOGs, Terminals, Marshalling boxes, probes, Jumpers, Termination of Cables in marshaling box, etc , Measurement of Insulation resistance, DC Resistance, ratios, voltages, Currents, earth resistance of individual earth pits & combined SS earth mat, etc, Checking up of alarms pertains to OT/WT/OLTC/MOG/Bucholtz, Conducting pre commissioning Tests of PTRs when commissioning at existing substations for every month
Testing of Transformer oil for dielectric breakdown strength. 800KVA DTR locations: Busareddypalli Intakewell-800KVA DTR Sl.No. 2207933 Toshiba make and 800KVA 2207919 Toshiba make.-2 No.s 630KVA DTR locations: Raghavapur IPS-DTR,630KVA, I no.Make:ESENAR Transformers(P) Ltd Sl.No.ET2-l244 500KVA DTR locations: Raghavapur IPS-DTR,630KVA, I no.Make:ESENAR Transformers(P) Ltd Sl.No.ET2-l244 Pampahad-1No. Thammadpally -TSSPDCLDTR,500KYA,2no's.Make:KRKPower Pvt.LtdSl.No.1285,1360 Aliabad-TSSPDCLDTR,500KVA,1 nos.Make:KRKPowerPvt.LtdSl.No.1359 160KVA DTR locations: Kavelly-TSSPDCL DTR, 160KVA, I no.Make:KRK Power Pvt.LtdSl.No.334 250KVA DTR locations: Pastapur-TSSPDCL DTR, 250KVA, I no. Mahabathpur-250KVA 160 KVA DTR locations: Tallapally intake well -TSSPDCL DTR Tallapally -TSSPDCL DTR, 63 KVA DTR locations: koheeer -TSSPDCL DTR, 63KVA, Hugelli -TSSPDCL DTR, 63KVA 100 KVA DTR locations: Nallampally -TSSPDCL DTR, 100KVA, Indrasham -TSSPDCL DTR, 100KVA,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQItemswb.xls
TENDER_DOCUMENT • 0.10 MB
Tender BID Vol Sangareddy Segment 11.09.2026.docx
TENDER_DOCUMENT • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .