| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-AOC NEAR ROADWAYS WORKSHOP PITHORAGARH DISTRICT PITHORAGARH | ₹7.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹8.4 Cr+₹1.1 Cr (15.4%)Rejected-Finance | ₹8.4 Cr+₹1.1 Cr (15.4%) | L2 | Rejected-Finance rejected being to be 2nd lowest |
| 3 | L3₹8.8 Cr+₹1.5 Cr (21.0%)Rejected-Finance ALMORA | UTTARAKHAND | 263601 | ₹8.8 Cr+₹1.5 Cr (21.0%) | L3 | Rejected-Finance rejected being to be 3rd lowest |
| 4 | L4₹9.0 Cr+₹1.7 Cr (24.0%)Rejected-Finance A 127 SHIVAM VIHAR RAJPUR ROAD JAKHAN DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹9.0 Cr+₹1.7 Cr (24.0%) | L4 | Rejected-Finance rejected being to be 4th lowest |
| 5 | Not Admitted-Fee/PreQual/Technical CORPORATE OFFICE E BLOCK E44 GROUND FLOOR SECTOR 36 G B NAGAR 201310 | NAGAR | G B NAGAR | UTTAR PRADESH | 201310 | - | - | Not Admitted-Fee/PreQual/Technical Others-hard copy submitted by bidder but DD and FDR not submitted by bidder |
Tender Value
₹8.8 Cr
EMD Value
₹17.6 L
Closing Date
12 Jan 2024, 5:00 pmClosed
GENERAL MANAGER CONSTRUCTION WING UKPJN HALDWANI
Office of the General Manager (kumaon), Nirman Wing Uttarakhand Peyjal Nigam, Haldwani.
CONSTRUCTION OF ROADWAYS WORKSHOP AT PITHORAGARH, DISTRICT PITHORAGARH
2023_MDPEY_66350_1
3156/nivida pithoragarh/124 dated 13/12/2023
Open Tender
Civil Works
Item Rate
450 days
Pithoragarh
as per tender documents
2 documents required · 2 mandatory
₹11,800
PM CONSTRUCTION UNIT UKPJN PITHORAGARH
₹17.6 L
PM CONSTRUCTION UNIT UKPJN PITHORAGARH
20 Feb 2024
14 Dec 2023
16 Jan 2024
14 Dec 2023
12 Jan 2024
19 Dec 2023
18 Dec 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
Cartage of material by mannual labour inculding loading ,unloading & stacking up to 50m
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 SQM on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Diluting and injecting chemical emulsion (chlorpyriphos/Lindane E.C 20% with 1% concentration) at the rate of one litre per hole at 300 mm c/c to all the horizontal and vertical surface of the excavation made for the foundation of the building, soil under floor,apron, back fill material and along all the faces of the walls for PRE-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) as per IS:6313 Part-II. (Plinth area of building shall be measurd for payment.)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material
M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Sepration Membrane of Impermeable Plastic Sheeting 125micron Thick
Cement Concrete (PCC M-30) Pavement:- Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M- 30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834.
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level
Providing units of reinforced cement concrte 1:1.5:3(1cement :1.5 coarse sand:3graded stone aggregate 20mm.nomnal size) of strength not less than M-150 in lintels and band over door and windows excluding supply of reinforcement and its bending including
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centring and shuttering including strutting, propping etc. and removal of form for:- Foundations, footings, bases of columns, etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for:- Center Shuttering
Centring and shuttering including strutting, propping etc. and removal of form for:- Columns, Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for:- Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Centring and shuttering including strutting, propping etc. and removal of form for:- Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-mechanically treated bars.
Brick work with Ist class bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarde sand)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per SQM as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Interlocking Concrete Block Pavement Providing and Laying of Interlocking Concrete Block (M-35) Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Steel work welded in built-up sections / framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.
Landscapping & horticulture work As per CPWD
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work ( two or more coats) over and including priming Coat with cement primer complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing ball bearing for rolling shutters.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per SQM as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per SQM, including pointing in white cement mixed with pigment of matching shade
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ SQM including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/SQM mixed with water proofing cement compound @ 0.253 kg/ SQM. This layer will be allowed to air cure for 4 hours (b) Second layer of slurry of cement @ 0.242 kg/SQM mixed with water proofing cement compound @ 0.126 kg/SQM. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.1 Profile B 10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90 mm
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete :150 mm
Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
Providing and fixing white viterous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & CP flush bend with fittings & CI brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing C.P. brass short body bib cock with flange of approved quality confirming to IS: 8931 15mm nomonal bore
Providing and fixing wash basin with CI/MS brackets, 15mm CP brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fitting and brackets, cutting and making good the walls wherever required. White Vitreous China wash basin (oval) size550 x 400 mm with single 15mm CP brass pillar tap
White Vitreous China flat back wash basin size550 x 400 mm with single 15mm CP brass pillar tap
Providing & fixing PTMT Bottle trap for wash basin and sink Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass union and G.I clamps complete, including painting and brakets, cutting and making good the walls and floor wherever required One urinal basin with 5 litre white PVC automatic flushing cistern
Providing and fixing C.P. brass quality angle valve15 mm dia. For basin mixer and gyser points of approved quality, confirming to IS : 8931 15mm nomonal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS : 8931. 15mm nomonal bore
Providing & fixing PTMT liquid soap container109mm wide,125mm high and 112mm distance from wall of standard shape and brackets of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long,200mm wide with a minimum distance of 37mm from wall face with concealed fitting arrangement of approved quality and colour weighing not less than 88 gms.
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Providing & fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washer complete.
Providing and fixing toilet paper holder C.P. brass
Providing and fixing soil, waste and vent pipes: 100 mm dia Centrifugally cast (spun) iron socketed pipe as per IS 3989.
Providing and fixing soil, waste and vent pipes: 75 mm dia Centrifugally cast (spun) iron socketed pipe as per IS 3989
Providing and fixing M.S holder-bat clamps of approved design to sand cast iron/sand cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix ( 1cement:2coarse sand: 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc For 100 mm dia pipe
Providing and fixing M.S holder-bat clamps of approved design to sand cast iron/sand cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix ( 1cement:2coarse sand: 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc For 75 mm dia pipe
Providing and fixing bend of required degre with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989
Providing and fixing plain bend of required degree 100 mm Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989
Providing and fixing plain bend of required degree 75 mm Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989
Providing and fixing single equal plain junction of required degree with access door, insersion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S & S as per IS 3989
Providing and fixing single equal plain junction of required degree with access door, insersion rubber washer 3 mm thick, bolts and nuts complete. 75x75x75 mm Sand cast iron S & S as per IS 3989
Providing and fixing double equal plain inverted branch of required degree 100x100x100x100 mm Sand cast iron S & S as per IS 3989
Providing and fixing terminal guard. 100 mm Sand cast iron S & S as per IS 3989
Providing and fixing terminal guard. 75 mm Sand cast iron S & S as per IS 3989
Providing and fixing collar 100 mm Sand cast iron S & S as per IS 3989
Providing and fixing collar 75 mm Sand cast iron S & S as per IS 3989
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100 mm
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 75 mm
Providing and fixing M.S stays and clamps for sand cast iron / Centrifugally Cast (Spun) Iron Pipes iron pipes of diameter. 100 mm
Providing and fixing M.S stays and clamps for sand cast iron / Centrifugally Cast (Spun) Iron Pipes iron pipes of diameter. 75 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This include jointing of pipes & fitting with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. 50 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This include jointing of pipes & fitting with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. 62.50 mm nominal outer dia Pipes
Providing & fixing ball valve (brass) of approved quality, High or low pressure with plastic floats complete 15 mm nominal bore
Providing & fixing ball valve (brass) of approved quality, High or low pressure with plastic floats complete 20 mm nominal bore
Providing & fixing ball valve (brass) of approved quality, High or low pressure with plastic floats complete 25 mm nominal bore
Providing & fixing gun metal gate valve with C.I wheel of approved quality, (Screwd end) 32 mm nominal bore
Providing & fixing gun metal gate valve with C.I wheel of approved quality, (Screwd end) 40 mm nominal bore
Providing & fixing gun metal gate valve with C.I wheel of approved quality, (Screwd end) 50 mm nominal obore
Providing and placing on terrace (at all floor levels polyethylene water storage tank ISI : 12701 marked water storage tank with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base suport for tank
Constructing masonary chamber 30x30xx50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : f fine sand) for gate valve with C. I. susface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with F. P. S. bricks
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm Dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110mm Bend
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing 40mm dia with length not less than 700mm waste pipe for sink and wash basin. complete job.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200mm
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.300 mm dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Providing & fixing of R.C.C manhole covering tank (600 x 600)
Providing & fixing of foot rest in tank
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
ELECTRICAL WORKS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.( Lift well )
Wiring for group controlled (looped) light point / fan point / exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.-group-C
Wiring for circuit wiring alongwith earth wire with the following sizes of HR-FR-LSH-lead free copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing as required. (FOR POWER PLUG )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire for floor panel to L- DB
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire for floor panel to P-DB
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 16 Amp universal modular socket outlet and 15/16 amps modular switch,connection, painting etc as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and fixing of Following sizes of PVC conduit along with the accessories like Junction boxes, bends, socket, fish wire etc. on surface/recess with M.S. Clamps, nuts and bolts including cutting of the wall and making good the same in case of recessed conduit as required. for LV 20mm
Supplying and fixing of Following sizes of PVC conduit along with the accessories like Junction boxes, bends, socket, fish wire etc. on surface/recess with M.S. Clamps, nuts and bolts including cutting of the wall and making good the same in case of recessed conduit as required. for LV 25mm
Supplying and fixing of Following sizes of PVC conduit along with the accessories like Junction boxes, bends, socket, fish wire etc. on surface/recess with M.S. Clamps, nuts and bolts including cutting of the wall and making good the same in case of recessed conduit as required. for LV 32mm
Supplying and fixing of Following sizes of PVC conduit along with the accessories like Junction boxes, bends, socket, fish wire etc. on surface/recess with M.S. Clamps, nuts and bolts including cutting of the wall and making good the same in case of recessed conduit as required. for LV 40mm
Supply, fixing, connecting and testing of telephone / computer / TV modular sockets modular plate anodised MS box and blanking plate in surface / recessed including connectionetc as required. RJ-11 telephone socket two line with shutter
Supply, fixing, connecting and testing of telephone / computer / TV modular sockets modular plate anodised MS box and blanking plate in surface / recessed including connectionetc as required. TV antenna socket outlet
Supply, fixing, connecting and testing of telephone / computer / TV modular sockets modular plate anodised MS box and blanking plate in surface / recessed including connectionetc as required. Data -I/O (RJ-45 Connectors) + Dats Face Plate
Supplying and drawing following pair, 0.5 sq.mm. FR PVC insulated copper conductor, unarmoured telephone cable in existing surface/ recessed steel/ PVC conduit as required. 2 pair Telephone cable ( 0.5 sq.mm. )
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 8 way (4 + 24), Double door L-DB + P DB+U DB
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. 6-32 Amp (10KA) SP MCB 'C' Series
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp SPN RCCB with 100 ma fault current rating
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63A FP MCB
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. 40A FP MCB
Supply of lighting fixtures of surface mounted 36W 2x2 tile LED light. The LED source used shall be complying with LM80 standards & LED source efficacy >150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI>80. Integral Driver with constant current constant voltage (CVCC), P.F >0.95, THD<10% and Surge Protection of atleast 3.5KV.
Supply of lighting fixtures of surface mounted 15W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy >150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI>80. Integral Driver with constant current constant voltage (CVCC), P.F >0.95, THD<10% and Surge Protection of atleast 3.5KV.
Supply of lighting fixtures of surface mounted 12W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy >150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI>80. Integral Driver with constant current constant voltage (CVCC), P.F >0.95, THD<10% and Surge Protection of atleast 3.5KV.
20 W linear 4ft LED integrated batten made of ultra slim co-extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.White finish ABS end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. These end caps are snap-fitted to the fixture.High efficiency long life LED with lumen efficacy of 130 lm/W with viewing angle of 120º.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. Lumen Output of 2110 lumens with System efficacy of >105lm/W .CRI >80, Color temperature 6500K, THD <20% and PF>0.95,IP20 . Life class of 35,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ.
Supply of 10W LED BulK head Fitting, The LED source used shall be complying with LM80 standards & LED source efficacy >120 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W system efficacy with color temprature of 5700 deg K (ANSI Bin) and CRI>80. Integral Driver with constant current constant voltage (CVCC), P.F >0.9, THD<20%,IP65 and Surge Protection of atleast 5KV.
Supply of 100W flood light
Supply of following Ceiling Fan : 1200mm Sweep similar to Havells CAT no. - samart /RR Kabil
Supply of following Ceiling Fan : industrial wall bracket fan
Supplying of Heavy Duty Exhaust Fans 300 mm, 1400 RPM
Supplying of Heavy Duty Exhaust Fans industrial exhaust
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting/ LED Light fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening,including making the hole to suit the size of the above fan, making good the damage complete , connection , etc as required.-M/C ROOM & PUMP ROOM
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supply of UL approved low carbon high tensile steel rod with copper coating of min 254 micron JK Chemrode - 0110 CBR the dia should be 25 mm with length of 10 feet ( 3000 mm) . The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be tested from NABL lab for current discharge not less then 46kA peak. The Chemrode shall be surrounded with 25 kg ( 1 bag) of Earth enhance materiel JK Reslow according to IEC 62561-7 and the Chemical resistance value shall not increase more then 0.067 Ωm and same will be tested from NABL lab. along with earth pit chamber made up polyplastic. Size of -254x330x260 MM (Model similar to PPC01)
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supply and Installation 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required.
Supply and Installation 6 SWG G.I. wire on surface or in recess for loop earthing as required.
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm
11KV VCB SITC OF SF6 insulated, 11kV Extensible Compact VCB (type VCE) contained within a metal clad enclosure having degree of protection to IP-54, suitable for outdoor use, free standing and comprising, 1 – 630 Amp triple pole, vacuum circuit breaker with independent manually charged spring mechanism and fully rated earth switch with provision for earth of the cable. 1 - Air insulated cable box with gland plate suitable for a bottom entry 3 core cables up to 300 sq. mm. The unit will be complete with: 1 - Mimic diagram on front panel complete with status indicators 1 - Set of positive standard mechanical interlocks 1 - Set of current transformers for protective relays with ratio 100-50/1A 1 - Self powered relay: Ashida/Equivalent Reputed make 1 - Set of VPIS for Circuit breaker 1 - External stud for earthing connections 1 - SF6 gas pressure indicator and SF6 recharging facility 1 - Local ‘PULL TO TRIP’ mechanism for each breaker. 1 - Set of auxiliary terminals 1 - Operating handle MAKE :-LUCY / ABB
TRANSFORMER 1 No.3 phase 50 Hz 400 kVA, 11KV /415V, DYn11, core type double wound with copper conductor oil immersed ONAN cooled Distribution Transformer Off circuit Tap changer voltage ratio of 11 KV / 415V with HT & LT Cable Box. Tappings +5% to –15% in steps of 1.25% shall be provided at line end of HV winding. .Losses are as per IS -1180 Level 1 (New Ammendment)). Capacity 400 KVA Input terminals suitable for connecting 11KV XLPE aluminium conductor armoured cable enclosed in a cable box. Output terminals suitable for connecting 1.1 KV grade single core aluminium conductor cable enclosed in a cable Box. L.T. Aux. terminals connections - suitable for 1.1 KV grade PVC /XLPE cable on Transformer Part H.T.Aux. terminals – suitable for 11 KV grade XLPE Al. Cable on Transformer Part Output : 415 V +/- 1% , 3 phase 50 Hz ,Unbalanced load Winding temperature indicator with alarm and trip Contacts Pressure release valve / explosion vent to be provided on ther top of the tank. Silica gel breather Oil Temp. Indicator with alarm & trip Contacts
Medium Voltage Panel NOTE: ALL ACBs ARE REQUIRED WITH SAFETY SHUTTER, UNDER VOLTAGE RELEASE / SHUNT TRIP General Note for all Panels The Panels/ Switch-boards shall be fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel, Compartmentised design, modular construction with Form 4b separation for Main Panels & 3b for remaining, Mounting Plates and Internal Partition shall be made of 1.6/2.0mm Aluzinc sheet for better heat dessipation clear space of 300mm or as approved shall be left at the bottom.The operating handle of the topmost switch shall not be higher than 1800mm from the finished floor and maximum height of panels shall not more than 2400mm.The Panel shall be Powder coated to paint of desired shadend in an approved manner. Undervoltage Relay (27) Reverse power RELAY (32) Inverse Definite minimum time overcurrent relay Overvoltage Relay (59) Trip Circuit Supervision Relay Master Trip Relay Bucholz protection (only transformer switch ) (63) Emergency stop on each panel All incomers and Bus coupler panel door should be different colour coded for identification and mimic diagram in front of panel should be marks by reflector paints All ACB terminals shall have vertical-vertical configuration for termination of incoming & outgoing bus links. All MCCB’s up to 630A shall be provided with rear stud type terminations. Space heater, Thermostat, On/Off switch, LED Lamp , Door operated switch. "All ACBs shall have protection Releases with LSIG. All Multifunction meters shall communication on ethernet through ethernet ports and shall have % THD and individual harmonics till 15 order Mimic Diagram compulsary Supply, Erection, Testing and commissioning of Indoor type ( IP 54 Protection ) cubicle pattern LT Switch-Board with a rupturing capacity of 50 KA at 415 V for 1 sec or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 , fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in Compartmentised design, modular construction with Form 4b separation for Main Panels & 3b for remaining, Mounting Plates and all Internal Partition shall be made of 1.6/2.0mm Aluzinc sheet for better heat dessipation. The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides.The panel to be provided with PVC Sleeved 4 pole Electrolytic Al .Maximum Current density for the bus bars shall meet temp rise condition. Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal AL Earth Bus Bars in each section.(as per drawing- enclosed-Main LT Panel). Panel should be extensible type.
BUSCOUPLER x 1 Nos. For each: 1 Nos 800A FP EDO ACB 50kA Without protection 1 No. Breaker Control Switch 1sets ON,OFF indicating LED Lamps with backup MCB. BUSBAR :- FP aluminium bus bars of minimum 1000 Amp with heat shrinkable coloured sleeves , Shrouds at Joints and including DMC/SMC bus bars supports at required interval complete for cross section, side supports and their spacing etc. for withstanding fault level of 31 MVA for 1 sec OUTGOING Note:ON Indication Light for all Outgoings. with backup MCB Section-A 1 Nos. 320Amps TPN ,MCCB with Thermal Magnetic Release adjustable with rotary handle for 150KVAR capacitor Panel 1 Nos. 320Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for Workshop Area 3 Nos. 63Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for Plumbing, Spare 6 Nos. 63Amps FP ,MCB for DB's 6 Nos. 40Amps FP ,MCB for DB's Section-B 1 No. 200Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for Fire Fighting Panel 3 No. 125Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for EV Charging Stations, Spare 1 Nos. 100Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for Spare 2 Nos. 63Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for External Lighting, Spare This panel should include 1 no. Busbar mounting Surge Protection Device Class B+C/ Class 1+2 Tested as per IEC 61643 Part 11:2011 & UL 1449 4th edition . Nominal voltage -230V 50/60Hz, MCOV of 350 V , Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level <1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min > 440 V and with out Follow Current & the Protection Modes for : L & N to PE . The connections (Three Lines & Neutral) should be directly connected to Protective Earth Terminal for better response time. Short- Circuit Current rating (Isccr) – 85 kA/50 Hz. Total Response time < 1 nano sec. Miscellaneous items 2 nos door switch 2 nos illumination lights with 6 A,10kA MCB ILLUMINATION LED WITH HOLDER & DOOR SWITCH 2 nos 6" dia exhaust fan with thermostate & suitable canopy Internal illumination in Cable alleys with Door operated switch. complete panel as above
Branch Protection 2 nos 10 amp TP 10 KA MCB for 5 KVAr 3 nos 20 amp TP 10 KA MCB for 10 KVAr 1 nos 32 amp TP 10 KA MCB for 15 KVAr 1 nos 40 amp TP 25 KA MCCB for 20 KVAr 3 nos 63 amp TP 25 KA MCCB for 25 KVAr Capacitor Duty Contactor 2 nos. Capacitor duty contactor suitable rating for 5 kVAR Rating 3 nos. Capacitor duty contactor suitable rating for 10 kVAR Rating 1 nos Capacitor duty contactor suitable rating for 15 kVAR Rating 1 nos. Capacitor duty contactor suitable rating for 20kVAR Rating 3 nos. Capacitor duty contactor suitable rating for 25kVAR Rating Detuned Harmonic Filters 2 nos. 440 V, 14% detuned 5 Kvar reactor 3 nos. 440 V, 14% detuned 10 Kvar reactor 1 nos. 440 V, 14% detuned 15 Kvar reactor 1 nos. 440 V, 14% detuned 20 Kvar reactor 3 nos. 440 V, 14% detuned 25 Kvar reactor Capacitor Banks 2 nos. 525 V, 10 kvar super heavy Capacitor Bank for 5 kvar 3 nos. 525 V, 12.5 kvar super heavy Capacitor Bank for 10 kvar 1 nos. 525 V, 20 kvar super heavy Capacitor Bank for 15 kvar 1 nos. 525 V, 25 kvar super heavy Capacitor Bank for 20 kvar 3 nos. 525 V, 30 kvar super heavy Capacitor Bank for 25 kvar Miscellaneous items 4nos door switch 4 nos illumination lights with 6 A,10kA MCB ILLUMINATION LED WITH HOLDER & DOOR SWITCH 4 nos 6"" dia exhaust fan with thermostate & suitable canopy Internal illumination in Cable alleys with Door operated switch. Complete Panel as Above and complete " Complete Panel as Above and complete
Fabrication supply, installing,testing & commission and connecting with main LT Panel of indoor type dust and vermin proof hinged and lockable doors at back side made out of 14 SWG CRCA MS Sheet including painting and complete with interconnections, Top entry, cable glands,removable gland plate, plugs, bonding to earth with 2 independent earth connections having 2 nos 25x6mm GI strip at bottom of panel as earth bus ,the construction of panel shall be compartmentalised, very compact, easy in maintenance .provision of ventilation shall be through axial flow fans system Legend plate of suitable size of showing panel no. and name of panel for outgoing feeder and as per the following and as per drawing for Workshop Panel INCOMER:- 1 Nos. 320Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle from Rising Main 1 set Phase Indicating LED 1 Nos Multifinction Meter With RS-485 port 1 sets Current Transformer 320/5A, Cl-1.0, 10VA 6 Nos. Control MCB BUSBAR :- 400 Amps 4 pole aluminum conductor ( CD 0.8A /sq.mm. ) bus bar (PVC sleeve Heat-shrinkable busbar insulation) supported by DMC / FRP insulator (MAIN BUSBAR) OUTGOING 1 Nos. 100Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle 5 Nos. 63Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle 2 Nos. 40Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle 3 Nos. 63Amps FP ,MCB 2 Nos. 40Amps FP ,MCB 4 Nos. 32Amps FP ,MCB 2 Nos. 16Amps FP ,MCB 2 Nos. 10Amps FP ,MCB 1 No. Type C SPD with indication and fuse. complete panel as above
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx10
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx16
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx25
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx35
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx50
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx70
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx95
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx120
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as requiredB 3.5Cx150
Supply and Laying of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level and connection legs,glands etc complete in all respects. Control cable 10 core 2.5 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 95 sq. mm and upto 185 sq. mm
"Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required." Upto 35 sq. mm (clamped with 1mm thick saddle)
"Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required." Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
"Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required." Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
"Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required." Upto 35 sq. mm (clamped with 1mm thick saddle)
"Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required." Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
"Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required." Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4Cx10 sq. mm (25mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4Cx16 sq. mm (28mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 4 X 25 sq. mm (28mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 35 sq. mm (32mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 50 sq. mm (35mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 70 sq. mm (38mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 95 sq. mm (45mm
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 120 sq. mm (45mm)
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 3½ X 150 sq. mm (50mm)
Supply & Testing of following 11 KV( UE) grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required. 3 C x 70 Sq. mm 11 KV (E)
H V CABLE LAYING Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 120 sq. mm
H.T Termination: Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 120 Sq.mm
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required 120 Sq.mm
Hot Dipped Galvanized Iron Cable Tray 4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as requiredSupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 150 mm width X 50 mm depth X 1.6 mm thickness
Hot Dipped Galvanized Iron Cable Tray 4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as requiredSupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 300 mm width X 50 mm depth X 1.6 mm thickness
Hot Dipped Galvanized Iron Cable Tray 4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as requiredSupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 450 mm width X 50 mm depth X 2.0 mm thickness
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red colour on front side as required.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required 150 mm dia
Construction of masonary chamber 900 x 900 x 1000 size
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 63 mm dia (OD-63 mm & ID-51 mm nominal
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 90 mm dia (OD-90 mm & ID-76 mm nominal)
SITC of “Silent Type” following KVA Sound Attenuated DG Set comprising of engine coupled to 415V, following KVA alternator mounted on a common Base Frame along with other accessories i.e. Engine Control Panel Auto/Manual (Mounted on Engine), Fuel tank, Batteries with leads i/c AMF Panel etc. as reqd. complete. The DG Set should be supplied with cable end box to accommodate suitable size and no. of cable on alternator complete as reqd. The canopy should be designed in such a way so that the Noise level can be restricted to 75 db level at a distance of 1 meter away from the DG Set. "Diesel engine 4 stroke, 6 Cylinder in Line, full Authority Electronic Engine with Mechanically Actuated Electronic Fuel Ignition System & EUI Injectors controlled by Electronic Control module , Displacement of 250 KVA diesel engine should not more than 16 L, Service Time interval 500 Hr/1 Year Whicever is earliear, water cooled, electric start, of suitable BHP at 1500 RPM suitable for following KVA output of alternator at 40 Degree C, 50%RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories, Factory Inspection of complete Silent DG Set must be at principle Engine Manufacturer Work, genset must be fuel efficient at partial load like 25%,50%,75%&100%, Complete package manufacture factory. Engine mounted Instrument Panel (Auto/Manual) fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip pressure indication (ix)DG Controller having feature to show HSD fuel consumption Units/ ltr. (x) Engine Hours indication
Alternator : Synchronous alternator rated at following KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation Base Frame & Foundation FOR Engine and Alternator: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Base Frame & Foundation For Daily Service Fuel Tank: Fuel tank of suitable as per mfg Standard capacity for fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Exhaust System: Dry exhaust manifold with Industrial Grade exhaust silencer. Starting System: 24v DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp / as per OEM.-Hour capacity lead acid type) as required as per specifications. Acoustic and weather proof enclosure Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications." 320 KVADG Set
SITC of “Silent Type” following KVA Sound Attenuated DG Set comprising of engine coupled to 415V, following KVA alternator mounted on a common Base Frame along with other accessories i.e. Engine Control Panel Auto/Manual (Mounted on Engine), Fuel tank, Batteries with leads i/c AMF Panel etc. as reqd. complete. The DG Set should be supplied with cable end box to accommodate suitable size and no. of cable on alternator complete as reqd. The canopy should be designed in such a way so that the Noise level can be restricted to 75 db level at a distance of 1 meter away from the DG Set. "Diesel engine 4 stroke, 6 Cylinder in Line, full Authority Electronic Engine with Mechanically Actuated Electronic Fuel Ignition System & EUI Injectors controlled by Electronic Control module , Displacement of 250 KVA diesel engine should not more than 16 L, Service Time interval 500 Hr/1 Year Whicever is earliear, water cooled, electric start, of suitable BHP at 1500 RPM suitable for following KVA output of alternator at 40 Degree C, 50%RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories, Factory Inspection of complete Silent DG Set must be at principle Engine Manufacturer Work, genset must be fuel efficient at partial load like 25%,50%,75%&100%, Complete package manufacture factory. Engine mounted Instrument Panel (Auto/Manual) fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip pressure indication (ix)DG Controller having feature to show HSD fuel consumption Units/ ltr. (x) Engine Hours indication
Alternator : Synchronous alternator rated at following KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation Base Frame & Foundation FOR Engine and Alternator: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Base Frame & Foundation For Daily Service Fuel Tank: Fuel tank of suitable as per mfg Standard capacity for fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Exhaust System: Dry exhaust manifold with Industrial Grade exhaust silencer. Starting System: 24v DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp / as per OEM.-Hour capacity lead acid type) as required as per specifications. Acoustic and weather proof enclosure Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications." 160 KVADG Set
SERVO STABILIZER Supply, Installation, Testing And Commisioning of 1 No. Indoor Digital Micro Processor Based Servo Voltage Stabilizer 400 kVA, Linear Type, Indoor, 3 Phase, Balanced Type, Input Voltage 330-470V Output voltage 400V ±1% .
KBPL INFRASTRCUTURE PVT.LTD.
MANEESH CONSTRUCTION
COX INFRATECH PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .