| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | ₹27.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹27.8 L+₹7,696 (0.28%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹27.8 L+₹7,696 (0.28%) | L2 | Rejected-AOC Other Than Lowest Bidder |
| 3 | L3₹37.9 L+₹10.2 L (37.0%)Rejected-AOC | ₹37.9 L+₹10.2 L (37.0%) | L3 | Rejected-AOC Other Than Lowest Bidder |
| 4 | L4₹39.4 L+₹11.8 L (42.5%)Rejected-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹39.4 L+₹11.8 L (42.5%) | L4 | Rejected-AOC Other Than Lowest Bidder |
| 5 | L5₹45.3 L+₹17.6 L (63.7%)Rejected-AOC | ₹45.3 L+₹17.6 L (63.7%) | L5 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
23 Nov 2024, 6:00 pmClosed
GE Chandigarh
GE CHANDIGARH N AREA OLD AIRPORT ROAD CHANDIGARH
CA GE/CHD-63/2024-25 REPAIR TO DBs EARTHING SUBMAIN AND SERVICE CONNECTIONS TO CERTAIN BLDGS AT N AREA K AREA AND HALLOMAJRA AND REPAIR MAINT OF INTERNAL ELECTRIFICATION REPLACEMENT OF UNSV WIRING IN CERTAIN OTM ACCN AT K AREA UNDER GE CHANDIGARH
2024_MES_679163_2
GE/CHD-63/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandigarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹1 L
Yes
24 Jan 2025
1 Nov 2024
25 Nov 2024
1 Nov 2024
23 Nov 2024
11 Nov 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and not exceeding 10sqmm on plan and getting out complete all as specified.
Returning,filling in including spreding, levelling, watering and well ramming in layers not exceeding 25 cm thick each excavated soil in trenches after the pipes have been laid and tested completed as in soft/loose soil, complete all as specified.
Removing of surplus soil/excavated material to a distance not exceeding 50meter and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying burnt bricks sub class "B" old size for cable protection laid flat lengthsise perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Dismantaling of service wire any size upto 25sqmm 2core
Supply and fixing 4 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn into and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular including taking down old unserviceble all as required or directed.
Supply and fixing 6 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn into and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular including taking down old unserviceble all as required or directed.
Supply and fixing 10 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn into and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular including taking down old unserviceble all as required or directed.
Supply, laying in trenches or fixed to poles or passing through pipes and testing cable XLPE Insualted screened PVC bedded, galvanised steel strip or wire armored, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm 4 core complete all as specified and directed.
All as per item no. 10 above but size 16 sqmm 2 core
Supply & fixing sheet metal enclosure MCB distribution board, single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with aluminium bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply & fixing sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with aluminium bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply & fixing sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size aluminium bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
MCB DB, TPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
Supply & fixing vertical Distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Supply & fixing in replacement MCB single pole 240 volts any rating from 5 to 40 amps, with rupturing capacity 10 KA,including providing thimble for out going cables.
Supply & fixing in replacement MCB double pole 240 volts any rating from 5 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
Supply & fixing in replacement MCB double pole 240 volts any rating above 40 amps up to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
Supply & fixing in replacement MCB three pole 415 volts any rating from 40 to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
Earthing with steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron wire of size 4mm dia as earthing lead by means of nuts, bolts and washers of steel after welding of GI wire to earth electrode , 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.
Supply and fixing in repair GI wire of size 4 mm complete al as specified and as directed
Cutting chases, pining in. making good to brick wall facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed tubing or concealed conduit etc, and making good to match with existing specifications for cuttings exceeding 10 cm but not exceeding 20cm girth all as required at site or directed by Engr-in-charge.
Cutting chases, pining in. making good to PCC floor/ roads of any specifications, facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed tubing or concealed conduit etc, and making good to match with existing specifications for cuttings exceeding 10 cm but not exceeding 20cm girth all as required at site or directed by Engr-in-charge.
Cutting chases, pining in. making good to tiled floor facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed tubing or concealed conduit etc, and making good to match with existing specifications for cuttings exceeding 10 cm but not exceeding 20cm girth all as required at site or directed by Engr-in-charge.
Supply & fixing MCCB 3 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, breaking capacity 35 KA, ICS =100 ICU, 200Amps complete all as specifired and as directed by Engr-in-Charge.
Supply & fixing MCCB 3 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, breaking capacity 35 KA, ICS =100 ICU, 160Amps complete all as specifired and as directed by Engr-in-Charge.
Supply & fixing MCCB 3 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, breaking capacity 35 KA, ICS =100 ICU, 125Amps complete all as specifired and as directed by Engr-in-Charge.
Supply & fixing MCCB 3 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, breaking capacity 35 KA, ICS =100 ICU, 63Amps complete all as specifired and as directed by Engr-in-Charge.
Taking out existing damage/unservisable PVC\ XLPE insulated, armoured, aluminium conductor 1100V grade cable of any size and core from trenches, pipes, walls and/or poles, complete all as specified . NOTE: Excavation and earthwork shall be measured and paid for separaetly
Supply,Laying and testing PVC insulated,armoured heavy duty, electric cable with stranded aluminum conductor of size 3.5 core 70 sqmm 1100 volts grade, laid in trenches, passing through pipes, fixed along walls and/or poles complete all as specified of size complete all as specified and directed.
All as per item No 31 above but cable of size 50 Sq.mm, 3.5 core
All as per item No 31 above but cable of size 35 Sq.mm, 3.5 core
All as per item No 31 above but cable of size 25 Sq.mm, 3.5 core
All as per item No 31 above but cable of size 10 Sq.mm, 2 core
All as per item No 31 above but cable of size16 Sq.mm, 4 core
Supply & fixing in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size 70 Sqmm, 3.5 core complete all as specified
Supply & fixing in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size 25 Sqmm to 50 Sqmm, 3.5 core complete all as specified
Cutting road for passing the cable/pipe and making good with plain cement concrete 1:3:6, type C-1 using 20 mm graded crushed stone aggregates complete all as specified. Note :- 1.Average width of excavation 300mm,average depth 600mm and average thickness of PCC 450mmm, 2. PCC 1:3:6 Type C-1 shall be measured and paid separately
Supply & fixing in repair 50 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified.
Supply & fixing in repair 25 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified .
Taking out old unserviceable GI earthing , earthing strip etc complete including dismantling of PCC earth chamber and making good the disturbed surface
Supply , and laying in repair Copper earth plat of size 60cmx60cmx 3 mm thick (having drilled two Nos holes of dia 10 mm one at centre and other in between top and centre for fixing of GI strip/ GI wire any size ) laid vertically in centre of a earth pit of depth 4.5 Mtrs complete al as specified and as directed.
Supply , and laying in repair GI earth plat of size 60cmx60cmx6 mm thick (having drilled two nos holes of dia 10 mm one at centre and other in between top and centre for fixing of GI strip/ GI wire any size ) laid vertically in centre of a earth pit of depth 4.5 Mtrs complete al as specified and as directed.
Supply and fixing in repair GI Strip of size 32x6 mm with GI earth plate under item ser no 44 above complete al as specified and as directed.
Supply and fixing in repair Copper Strip of size 25x4 mm with copper plate earth plate under item ser no 43 above complete al as specified and as directed.
Supply and fixing in repair GI Strip of size 25x4 mm with GI earth plate under item ser no 44 above complete all as specified and as directed
Supply and fixing GI bolt( full thread) ,Nut and wahsers of size 10 mm thick 25 mm long
Supply and fixing brass bolt( full thread) ,Nut and wahsers of size 10 mm thick 25 mm long Note :( One GI bolt,one nut and two nos washers shall be considered as one set)
Supply and fixing in repair GI watering funnel with wire mesh
Supply and filling sea salt in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
Supply and filling charcoal dust in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge.
M&L PCC 1:3:6 Type C-1 using 20 mm graded black stone aggregate including necesary form work for repair of earth pit complete all as specified in SSR part I and as directed by Engr-in-charge.
Supply & fixing SPN AFDD 16A/32A/40A offering protections for overload, short circuit, Residual current characterisitics TYPE A, Over Voltage protection above 270 AC plus minus 5% & series parallel arc fault. AFDD must be dual test button for AFDD and Earth leakage functions along with single diagnostic LED with blinking patterns for continuous ON, Series Arc, Parallel arc and overvoltage protection.
Supply & fixing portable current residual device (PRCD) 16 A 30mA Euro II all as specified and as directed by Engr in charge.
Taking down unserviceable sub main wiring 10/6/4 Sqmm aluminium cable all as directed.
Sub main wiring/power wiring complete with two runs of 10 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated, 10 Sqmm FRLS copper conductor for earth continuity all as specified and as directed. Note :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
All as per item No 57 here in above but with 2X6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete.
All as per Item No 57 here in above but of 3X4 Sqmm.
Disconnection and removing the unserviceable 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and Material & Labour for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistandard with copper conductor drawn in the existing metal/PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete.
Disconnection and removing the unserviceable casing caping conduit and Supply & fixing PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete all as specified and as directed.
Taking down existing control board (Meter Box) and supply and fixing sheet metal board made of 1.6mm thick metal sheet and painting 2 coats with synthic enamel paint over a coat of primer including copper bus bar and fixed with wall for fixing meter complete with wiring, fitting and accessories, locking arrangements with handle (minimum size of box 65cmx75cm and adequate depth for the following equipments, internal wiring and termination of external cable, lugs and glands and conduits as required) comprising of following. (a) Incoming 100Amp 4 pole MCCB 25 KA-01 Nos. (b) Bus bar 100 Amp Aluminium (d) 10Amp DP MCB-01 No (Outgoing for stair case and garage) (c ) 40Amp DP MCB-04 Nos (for Qtr meters) (e) Fixing only arrangement for electronic type energy meters single phase 240Volt 40Amps 50HZ -04Nos. Note : Elect meter will be issued under Sch 'B' free for fixing only.
Disconnection & taking down the unserviceable GI bracket of size 25/32 mm dia from the pole / building and M&L for street light bracket made out of 25/32 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x6mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/building complete all as specified and as directed.
Disconnection & taking down the unserviceable building light high wattage (30/25 Watts) street light fittings and Supply & fixing energy efficient Intergral type LED 25W Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted testing compelte all as specified and directed.
Point wiring with 1.5Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS dolly in existing concealed/surface conduit including concealed in wall, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc for the One light point controlled by one way switch NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items.cable Colour should be as per IS code. (ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates.
All as per item No 66 above but One ceiling /exhaust fan point controlled by one, one way 5 Amps switch
All as per item No 66 above but One 3 pin socket outlet 5 Amps on independent board
All as per item No 66 above but One 3 pin socket outlet 5 Amps on same board
All as per item No 66 above but One light point controled by two, two way 5 Amps switches.
All as per item No 66 above but One bell point controlled by one way bell push switches.
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc all as directed by Engineer in Charge.
Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
Point wiring complete with 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
M&L for Sub main wiring/power wiring complete with two runs of 2.5 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated, 2.5Sqmm FRLS copper conductor for earth continuity complete all as specified and as directed. Note :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling.
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
Supply and Fixing Ding Dong AC 230 volts,single pole.
Supply and Fixing 5/6 Amps bell push one modular switch complete.
Supply & Fixing 5/6 Amps 1 way one modular switch complete.
Supply and Fixing 5/6 Amps three pin socket modular complete.
Supply and Fixing 15/16 Amps one way one modular switch complete.
Supply and Fixing 15/16 Amps three pin socket modular complete.
Supply and Fixing 5 Amps 2 way modular switch complete.
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed.
Disconnection and removing the u/s LED lamp and S&F LED lamp 9 watts complete all as specified and directed.
Supply & fixing MCB DB, SPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
Supply & fixing MCB DB, TPN, 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
Supply & fixing MCB DB, TPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
Supply & fixing MCB DB, TPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
Taking down existing unserviceable MCB DB/TPN along with MCBs complete by disconnecting all as directed.
Supply & fixing in replacement MCB SPN 240 volts any rating from 63 amps, with rupturing capacity 10 KA,including providing thimble for out going cables.
All as per Item No 92 here in above but of capacity MCB TPN 32 Amps
All as per Item No 92 here in above but of capacity MCB TPN 40 Amps
All as per Item No 92 here in above but of capacity MCB TPN 63 Amps
Disconnection and removing the u/s MCB plug and socket unit and Supply & fixing Single pole and neutral Enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Disconnection and removing the u/s light fitting and Supply & fixing as in repair batten for LED tube light 1X18/20 watts LED, 230Volt energy saving recess, industrial batton type, powder coated, CRCA Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair LED tube rod 1X18/20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 20W, complete all as specified and directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X10 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x10W, complete all as specified and directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and Supply & fixing surface mounting mirror light luminaire 10 watts LED, 230Volt energy saving accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting from the fall ceiling carefully and Supply & fixing LED (2X2) indirect light fitting circular shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Supply & fixing decorative Post top LED 40 Watt for 360* indirect light with IP 65 protection 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s light fitting from the Surface mountend carefully and Supply & fixing Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s round down light and Supply & fixing Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 22 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Disconnection and removing the u/s square downlight and Supply & fixing Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair batten LED 22 w inveter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 more than, driver efficiency ≥ 85%, operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge.
Material & Labour bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos and iron lead and suitable to accommodate 4 pole 63-100 Amps MCCB and provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface Note : MCCB shall be measured and paid separately
Supply & fixing in repair MCCB 4 pole 100 Amps 25 KA complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
All as per Item No 108 here in above but of capacity 4 pole 160 amps, 36 KA.
All as per Item No 108 here in above but of capacity MCCB 3 pole 100 Amp, 25KA.
Material and labour of LT Panel making electric connections incl wiring by Conductor multistranded PVC insulated welding of doors , fixing hinges, Thimble Refixing of MCCBs and brazing etccomplete all as specified and diercted by Engineer-in-Charge
Disconnecting and removing unserviceable Change Over and Supply & fixing of Change over switch 63 Amps, TPN, 415 volts rewirable fuse type complete all as specified and diercted by Engineer-in-Charge.
All as per Item No 112 here in above but of capacity 100Amp TPN, 415Volt complete all as specified and diercted by Engineer-in-Charge.
Supply and fix 4 module (gang box) plastic surface box with plate.
Supply and fix 6 module (gang box) plastic surface box with plate.
Supply and fix 8 module (gang box) plastic surface box with plate.
Supply and fix Modular metal flush terminal boxes with lumina plate and frame suitable for 1 module complete all as specified and directed.
Supply and fix Modular metal flush terminal boxes with lumina plate and frame suitable for 2 module complete all as specified and directed.
Supply and fix Modular metal flush terminal boxes with lumina plate and frame suitable for 3 module complete all as specified and directed.
Supply and fix Modular metal flush terminal boxes with lumina plate and frame suitable for 4-5 module complete all as specified and directed.
Supply and fix Modular metal flush terminal boxes with lumina plate and frame suitable for 6 module complete all as specified and directed.
Supply and fix Modular metal flush terminal boxes with lumina plate and frame suitable for 8 module complete all as specified and directed.
Supply and fix Modular blank plate one module.
GS Engineers (BID ID -3167253)
Ess Ess Engineers (BID ID -3167175)
M/s APEX ENTERPRISES (BID ID -3163059)
Bharat Enterprises (BID ID -3163817)
Electromech Engineers (BID ID -3164649)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .