| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹40.6 L+₹1.3 L (3.23%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹41.5 L+₹2.2 L (5.54%)Rejected-AOC | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹41.6 L+₹2.3 L (5.79%)Rejected-AOC | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹42.0 L+₹2.7 L (6.85%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
8 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Spl repair of roof for Bldg no T-102,103,104,105 and 119 at 127 Inf BN TA and certain Minor Works under GE Dehradun.
2023_MES_610784_2
8662/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹95,000
Yes
7 Oct 2023
24 Aug 2023
11 Sept 2023
24 Aug 2023
8 Sept 2023
1 Sept 2023
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Supply and fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed..
Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed
Supply and fix Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed
Dismantling of old Rolled sections as in main and cross beams, hip and jack rafters; purlins and refixing the same in other locations complete all as specified and directed.
Supply and fix MS plates( plain Q or Chequuered ) channels , Square cut or notched ( ordinary and counter sunk forming holes or welding to steel section complete all as specified and directed .
Material and labour applying two coats of synthetic enamel paint on new /old untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
Material and labour PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work and demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick in ground floor and paving below or above ground level complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets. complete all as specified and directed.
Supply & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights as per direction of Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour for brick work with sub class 'B' brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of existing old brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Taking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key,scrubbing down with water etc. complete all as specified and as directed.
Material and labour 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and fair complete all as specified and directed.
Material and labour for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth complete all as specified and directed.
Material and labour applying interior grade wall care putty 1-1.5 mm thick to make the surface smooth as specified and directed by Engr-in-Charge.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
Surface excavation in any type of soil n. exc. 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5cu m, getting ut,returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25cm watering and removing surplus soil to a distance n exc 50m and making good surface in hard/dense soil complete all as specified and as directed by the Engr-in-Charge.
Material and labour broken stones hardcore of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in sub base complete all as specified and as directed.
Material and labour Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
Material and labour Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
Material and labour for 60 mm thick pre polished rubber moulded Red/ yellow colour machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and directed by the Engr-in-Charge.
Material and labour PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and directed.
Supply and fix for joist, channel, angle, or tee section, fixed independantly, without connecting plates, etc. as in fencing, post conforming to Fe 410 W (gde E-250 quality B) complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Supply, installation & testing of modular bed head panel with electric switch socket and BS outlet points alongwith side cover, ralings, end closer of railing (50mm thickness, 914mm long ) all as specified and directed by Engr in charge.
Supply, installation & testing of aluminium sliding patient stand suitable for mounting medical equipments all as specified and directed by Engr in charge.
Supply & installation of patient monitar accessories basket all as specified and directed by Engr in charge.
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) any type including unscrewing from board,fitting and fixture such as switches, ceiling roses, holders, regulators sockets ,light fittings etc removing materials from site and making good disturbed with the existing surfaces complete all as directed.
Removing & Refixing as its existing position or new location the ceiling fan carefully including electric connection and arrangement of fan hooks suitable for hanging of ceiling fans complete all as specified & directed.
Taking down light fittings, hylum sheet including switches, sockests, fan regulators etc from sunken box by removing wires from switches, sockets, fan regulators etc and keep the safe for refixing the same location complete all as specified and directed.
Refixing the light fittings, hylum sheet including switches, sockests, fan regulators etc under item No 3 and connecting electric connection all as specified and directed.
M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness 1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls,floors etc complete all as specified and directed by Engr.-in-charge of following.
One light, bell, fan point controlled by one way switch.
One three pin 5 Amp socket on same board with other switches
One three pin 5 Amp socket on independent board
All as per Item No 5 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete all as specified and directed.
Supply and fix in repairs switch 6 Amps 230 Volts one way switch complete all as specified and directed.
Supply and fix in repairs Socket 6 Amps AC 230 Volts 2/3 pin combined type complete all as specified and as directed.
Supply and fix in repairs Socket 6A/16 Amps-2/3 pin AC 230 Volts combined type complete all as specified and as directed.
Supply and fix in repairs Switch AC 230 volts 16 Amps one way complete all as specified and as directed.
Supply and fix calling bell ding dong type AC 230 Volt single pole complete all as specified and directed.
Supply and fix in repairs step type regulator socket type 5 step for ceiling fan 1200/1400 mm size 230 volts, 6 Amps 100/120 watts complete all as specified and directed.
Supply and fix in repairs for ceiling rose, Three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified.
Supply and fix in repairs for Lamp holder polycarbonate insulated body, with back plate suitable for batton fitting complete all as specified and directed.
Supply and fix wall mounted LED tube light fitting 1x10 watts, 2 feet extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
Supply and fix wall mounted LED tube light fitting 18/20 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
Supply and fix in replacement of energy saving ,surface mounted, LED 10 watt Bulk head luminaire with decorative oval diffuser comprrising of high brightness LEDs complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement for Distribution board TPN 4 Way double door, for mounting MCBs/isolator, etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make
Supply and fixing in replacement for Distribution board SPN 8 Way double door, for mounting MCBs/isolator, etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make
Supply and fix ix in repairs MCB TPN 240 Volt 10 KA 63 Amp 'C' series conforming to IS complete all as specified & directed.
Supply and fix ix in repairs MCB SPN 240 Volt 10 KA 32 Amp 'C' series conforming to IS complete all as specified & directed.
Supply and fix ix in repairs MCB single pole 240 volt, 10 KA, 5-32 Amp, 'C' series confirming to IS complete all as specified and directed.
Material and labour for sub main wiring in repairs with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit/flexible conduit where reqd and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete. Note: (i) Earthing has to done by spl persons and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
Supply, installing, commissioning and testing of LT panel/ outdoor Kiosk type factory made weather and vermin proof fixed on and including ventilation and louvers arrangement, PCC (1:2:4) foundation of required/ suitable size and as directed at site with angle iron frame of size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase, 4 wire, 415 volts, 50 Hz, fabricated out of 3.15 mm thick MS sheet including two coats of synthetic enamel paint over a coat of primer red oxide paint and keeping adequate working space inside the box (outer width of the box not less than 45 cm and gap between bus bar not less than one inch) and double door be provided with proper hinged and sliding door handle including locking arrangement as directed and before manufacturing the panel and the same have the following electric controls :- (a) Insulation epoxy painted high conductivity aluminium bus bar 250 Amps for 3 phase and neutral complete all as specified and directed. (b) Digital Voltmeter 0 to 500 Volts - 01 set (c) Digital Ampere meter 0 to 200 Amps capacity - 01 Set (d) Indicating lamps Neon type for RYB - 01 set Incoming (a) MCCB 4 Pole 415 volts 200 Amps, 16 KA as incoming - 01 Nos. Make :- ABB/L&T/Legrand. Outgoing (a) MCCB 4 Pole 415 volts 63 Amps, 16 KA as outgoing - 03 Nos Make :- ABB/L&T/Legrand. (b) MCCB 4 Pole 415 volts 100 Amps, 16 KA as outgoing - 02 Nos Make :- ABB/L&T/Legrand.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 16 Sqmm 4 Core complete all as specified and directed.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete all as specified and directed.
Supply and fix tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
SRI GANESH ENTERPRISES
M/S JAI PRAKASH GOEL
kalakriti enterprises
PRAGATI ENTERPRISES
RISHU CONSTRUCTION COMPANY
M/S C S AITHANI
MOHAN LAL GUPTA
M/s Pradeep Kumar
M/s Teg Singh Negi
Laxmi traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .