Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Awarded contract being lowest | |
| 2 | L2₹34.1 L+₹2.4 L (7.40%)Rejected-AOC RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹40.9 L+₹9.1 L (28.7%)Rejected-AOC | L3 | Rejected-AOC Not being lowest | |
| 4 | L4₹40.9 L+₹9.1 L (28.8%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L4 | Rejected-AOC Not being lowest | |
| 5 | L5₹41.2 L+₹9.5 L (29.9%)Rejected-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L5 | Rejected-AOC Not being lowest |
| Sl No | Description | Qty | Unit | SANDR L2 | Jack Electrolinks Private Limited L5 | LAKSHMI BUILDERS L3 | Green Ray Enterprises L4 | SREEKRUPA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Note : 1. The contractor should visit at site before quoting the tender to know the working condition of the station. 2. All requisite safety measures adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electrician ( as approved by GE/ Engineer in charge) shall report at 9.00 hrs to JE E/M / Engineer in charge to collect the complaints in working days and complete the same complaint within 24 Hrs. 4. The complaints shall be rectified with in 24 Hrs if the complaints is/ are not attended / not completed with in 24 Hrs ( except repair/ replacement of major items) recovery will be done Rs 500 per complaint per day. 5 For major parts like rplacement of MCB Dbs, MCCBs should be rectified within 5 working days, if the contractor not rectify within time then recovery will be done Rs 1000 per complaint per day. 6 If contractor failed to provide their electrician or attend the complaints then recovery will be doneRs 1000 per day. | ||||||||
| 2.00 | Material and Labour in replacement of old unserviceable sub main wiring using 4 runs of 10 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through in and including PVC casing and caping surface on wall along with 1 runs of 10 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly and including taking down old unserviceable wiring and including making good the existing disturbed surface using wall care putty and matching colour emulsion paint. complete all as specified and directed by Engr-in-charge. | 20 | RM | 650 ₹13,000 Lowest | 1,050 ₹21,000 | 650 ₹13,000 Lowest | 1,050 ₹21,000 | 1,400 ₹28,000 |
| 3.00 | All as per item no 02 here in before but of size 4 run of 6 sqmm and 1 run of 6 sqmm for earth lead complete all as specified and directed by EIC. | 20 | RM | 450 ₹9,000 | 650 ₹13,000 | 380 ₹7,600 Lowest | 625 ₹12,500 | 850 ₹17,000 |
| 4.00 | All as per item no 02 here in before but of size 4 run of 4 sqmm and 1 run of 4 sqmm for earth lead complete all as specified and directed by EIC. | 20 | RM | 350 ₹7,000 | 450 ₹9,000 | 300 ₹6,000 Lowest | 505 ₹10,100 | 580 ₹11,600 |
| 5.00 | All as per item no 02 here in before but in of size 2 run of 2.5 sqmm and 1 run of 2.5 sqmm for earth lead Note for item No. 2 to 5:-(i) One run of PVC casing and caping along with 5 runs / 3 runs of respective size of PVC insulated copper conductor cable will be measured as one unit.(ii) Strictly follow the proper colour code red/yellow/blue for phase ,black for neutral and green for earth. | 250 | RM | 195 ₹48,750 Lowest | 385 ₹96,250 | 200 ₹50,000 | 295 ₹73,750 | 300 ₹75,000 |
| 6.00 | Material and Labour in replacement of old unserviceable sub main wiring using 2 runs of 10 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through in existing conduit surface on wall along with 1 run of 10 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly and including taking down old unserviceable wiring and including making good the existing disturbed surface using wall putty and matching colour emulsion paint. complete all as specified and directed. | 90 | RM | 600 ₹54,000 | 750 ₹67,500 | 300 ₹27,000 Lowest | 740 ₹66,600 | 600 ₹54,000 |
| 7.00 | All as per item No.06 here in before but in size 2 runs of 6 sqmm and 1 run of 6 sqmm as earth | 180 | RM | 320 ₹57,600 | 500 ₹90,000 | 250 ₹45,000 Lowest | 490 ₹88,200 | 550 ₹99,000 |
| 8.00 | All as per item No.06 here in before but in size 2 runs of 4 sqmm and 1 run of 4 sqmm as earth | 250 | RM | 230 ₹57,500 | 475 ₹1,18,750 | 200 ₹50,000 Lowest | 410 ₹1,02,500 | 350 ₹87,500 |
| 9.00 | All as per item No.06 here in before but in size 2 runs of 2.5 sqmm and 1 run of 2.5 sqmm as earth
Note for Srl item no 06 to 09
1. Wire shall be drawn though existing conduict.
2. 3 run of cables shall be measured as one unit.
3. Colour code shall be followed. | 320 | RM | 200 ₹64,000 | 325 ₹1,04,000 | 180 ₹57,600 Lowest | 290 ₹92,800 | 250 ₹80,000 |
| 10.00 | Supply and fix in replacement old unserviceable wall mounted 10 W 2 ft LED batten, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed. | 350 | Each | 450 ₹1,57,500 | 325 ₹1,13,750 Lowest | 1,200 ₹4,20,000 | 520 ₹1,82,000 | 350 ₹1,22,500 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
5 Jun 2026, 4:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2026_MES_765331_1
GE MAINT EZHIMALA 8856
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹96,000
Yes
2 Jul 2026
14 May 2026
11 Jun 2026
14 May 2026
5 Jun 2026
29 May 2026
14 May 2026 - 21 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Material and Labour in replacement of old unserviceable sub main wiring using 4 runs of 10 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through in and including PVC casing and caping surface on wall along with 1 runs of 10 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly and including taking down old unserviceable wiring and including making good the existing disturbed surface using wall care putty and matching colour emulsion paint. complete all as specified and directed by Engr-in-charge. | 20 | RM | - | - |
| 3 | All as per item no 02 here in before but of size 4 run of 6 sqmm and 1 run of 6 sqmm for earth lead complete all as specified and directed by EIC. | 20 | RM | - | - |
| 4 | All as per item no 02 here in before but of size 4 run of 4 sqmm and 1 run of 4 sqmm for earth lead complete all as specified and directed by EIC. | 20 | RM | - | - |
| 5 | All as per item no 02 here in before but in of size 2 run of 2.5 sqmm and 1 run of 2.5 sqmm for earth lead Note for item No. 2 to 5:-(i) One run of PVC casing and caping along with 5 runs / 3 runs of respective size of PVC insulated copper conductor cable will be measured as one unit.(ii) Strictly follow the proper colour code red/yellow/blue for phase ,black for neutral and green for earth. | 250 | RM | - | - |
| 6 | Material and Labour in replacement of old unserviceable sub main wiring using 2 runs of 10 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through in existing conduit surface on wall along with 1 run of 10 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly and including taking down old unserviceable wiring and including making good the existing disturbed surface using wall putty and matching colour emulsion paint. complete all as specified and directed. | 90 | RM | - | - |
| 7 | All as per item No.06 here in before but in size 2 runs of 6 sqmm and 1 run of 6 sqmm as earth | 180 | RM | - | - |
| 8 | All as per item No.06 here in before but in size 2 runs of 4 sqmm and 1 run of 4 sqmm as earth | 250 | RM | - | - |
| 9 | All as per item No.06 here in before but in size 2 runs of 2.5 sqmm and 1 run of 2.5 sqmm as earth
Note for Srl item no 06 to 09
1. Wire shall be drawn though existing conduict.
2. 3 run of cables shall be measured as one unit.
3. Colour code shall be followed. | 320 | RM | - | - |
| 10 | Supply and fix in replacement old unserviceable wall mounted 10 W 2 ft LED batten, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor complete all as specified and directed. | 350 | Each | - | - |
| 11 | Supply and fix in replacement of old unserviceable wall mounted 20 W LED 4ft white batten and including connecting up 3 core flexible copper conductor cable suitable size from fitting to ceiling rose/connection terminals all as specified and directed | 750 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.09 MB
TenderDocument8856.pdf
Tender Documents • 1.07 MB
BOQ_857168.xls
BOQ • 2.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .