| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.8 LAccepted-AOC KHASRA NO 203 KHARAKPUR DEVIPURA KASHIPUR | KASHIPUR | 1 | Accepted-AOC MOM C-393 dt 26.06.2023 | |
| 2 | 2₹20.5 L+₹68,194 (3.44%)Rejected-Finance VILLAGE BAHRUWALA POST GOVERDHANPUR TEHSIL LAKSAR ROORKEE | HARIDWAR | UTTARAKHAND | 247656 | 2 | Rejected-Finance Bidder are Second | |
| 3 | Not Admitted-Fee/PreQual/Technical NANDA VIHAR DHANAURI PATTI RAMNAGAR ROAD KASHIPUR DISTT U S NAGAR UTTARAKHAND | ALMORA | UTTARAKHAND | 244715 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹59,700
Closing Date
19 May 2023, 11:00 amClosed
Superintending Engineer
Bijli Bhawan Bazpur Road Kashipur
Increase of different capacity of distribution Transformer 25/63/100/250 KVA and supply of its associated decentralized material in different site under EDSD Doraha under EDD Bazpur
2023_UPCL9_57663_1
E Tender No 07/EDC(Kashipur)2023-24
Open Tender
Electrical Works
Item Rate
365 days
Bazpur
As per Tender NIT and Tender Documents
3 documents required · 3 mandatory
₹1,180
Yes
EE EDD Kashipur
₹59,700
Yes
2 Aug 2023
22 Apr 2023
23 May 2023
24 Apr 2023
19 May 2023
24 Apr 2023
Supply Item
Supply of Aluminium Crimping Lug Size 250 sq mm made of best Quality Pore Line and Without Defeets ISI Standerd. (As per Specification of UPCL)
Supply of LT Air Circuit Breaker (ACB) Type Complete LT Distribution Board for 250 KVA Transformer DTR fitted with 1 No 800 Amp CT Including Mircroprocessor release IPR-1 manual Opreated Fixed Type (4 Poles as per IS-13947-2 & IEC 60947-2 with Panel and mounting structure). Make (IS Complied Reputed Company)
Transformer and ACB Installation Work
Cartage of the following material by private truck from store centre Rudrapur /Haldwani/ Kashipur to work site dump store approx. distance 10 to 80 Km. including loading into truck and unloading at Dump store.
63 KVA T/F
100 KVA T/F
250 KVA T/F
400 KVA T/F
Cartage and Head Load Cartage of ACB From dump Store to work site approx. distance 5 Km. including loading and unloading.
Construction of Transformer Plinth with size 2x2x1.1 meter above ground level and 0.6 mtr below level including the cost of material such as cement brick, ballast, sand etc. including Labour Charges in Direction of Engineer In-Charges Complete works as per Specification of UPCL.
Providing and fixing of wire mesh of size 50x35 mm around plinth and toe wall duly welded with frame of MS angle iron 35x35x6 mm and strip of size 35x6 mm in mid of each side along with wire mesh (width of wire mesh 1.5 meter) with the height of 0.5 meter above the plinth 2 meter above the toe wall complete in all respect as per specification of UPCL.
Dismentling of the Following Transformer Form Various work Site of Double Pole Structure complete in all respect.
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
Mounting of following Capacity Transformer/Plinth/Double Pole Structure with the help of Chain Pulley/Crain Depending upon the nature of Job at work complete in all respect and Energisation of Transformer
63 KVA T/F
100 KVA T/F
250 KVA T/F
400 KVA T/F
Back Cartage of the Following Transformer Form Various work Site to safe place on JE Store/Store Centre Kashipur by Private truck within average lead distance of approx 1 to 40 Km including loading & unloading proper stacking at store complete in all respect.
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
Installation of LT Air Circuit Breaker (ACB) LT Distribution Board complete in all respects i.e, disconnection of existing cable from DTR Terminal and Metering Cubicals, fixing of new additional cable in ACB LT Distribution board, Testing and comissining of ACB connection, complete in all respect.
Supply & Installation of Chemical Earthing to Air Circuit Breaker (ACB) Completed in direction of Engineer In- Charges Completed works in all respect as per Specification of UPCL.
Laying of LT XLPE Cable 1x240 sq mm in all respect as per Specification of UPCL.
AMC of ACB Only for Ist Year after Installation and expiry of warranty of One Year incl spare parts (3% value of ACB) L/S.
Earthing of DTR Neutral/Body with M.S. earthing rod 20×2500 mm for earthing of support as per RESPO drawing No. RES-12 including digging earth rod 2.5 m deep below ground level connected to support with earth wire 7/16 swg fixing of all accessories complete in all respect as per Specification of UPCL.
m/s ss infra power
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .