Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 CrAdmitted-Finance 4TH FLOOR SKV TOWER PLOT NO 57 SECTOR 18 GURUGRAM 122015 HARYANA | GURUGRAM | GURUGRAM | HARYANA | 122015 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | WAPCOS LIMITED L1 |
|---|---|---|---|---|
| 1.00 | COLD SURVEY (with water depleted condition)Inspection of water conducting system (around 3.5 Kms in length, & 3m dia)viz., Head Race Tunnel (HRT), Head Race Surge Shaft (HRSS) height of 86.5m & 15m dia , Tail Race Tunnel (TRT) & Tail Race Surge shaft (TRSS) of height 65.5m & dia of 20m, along with other civil works, all hydro-mechanical and electro-mechanical equipments including Governor system & Control systems using specialised trolley arrangement to travel into the water conducting system for inspection. | 1 | LS | 16,00,000 ₹18,88,000 Lowest |
| 2.00 | HOT SURVEY (machine in running condition): Survey and observations of equipments to ascertain their conditions and identification of problem area for analysis and conducting tests as per CEA guidelines by experts in each and every area to be tested has to be engaged.
Tests:
1. Diagnostic tests on Generating Units.
2 Diagnostic studies on Mechanical Equipment viz. runner, guide vanes, shafts, etc.
3. Dynamic Behaviour Tests/ Vibration Analysis
4.Structural Studies
5. Non- Destructive and Destructive type tests | 1 | LS | 1,60,00,000 ₹1,88,80,000 Lowest |
| 3.00 | Model testing along with Computational Fluid Dynamic (CFD) Analysis to be performed in order to observe the Output of the turbine & study for the enhancement of the machine efficiency by considering turbine runner profile & further detailed turbine analysis . Hydraulic design of new runner shall be carried out for uprating capability studies for which necessary CFD analysis followed by model study, conducting homologous model. Model test shall be carried out in an internationally accredited laboratory. Prior to testing, approval shall be obtained from TNGECL for the proposed lab. | 1 | LS | 2,50,00,000 ₹2,95,00,000 Lowest |
| 4.00 | Various tests have to be conducted on the main equipments in any one of the Units , both in running & idle condition.
Dismantling of components to ascertain the conditions of various sub-components , conducting tests with various testing equipments, tools & machineries along with specialised experts in respective testing parameter field has to be engaged.
After completion of testing, the dismantled components need to be assembled back in position.
(Dismantling, Reassembling and commissioning are under the scope of the Contractor ) | 1 | LS | 1,60,00,000 ₹1,88,80,000 Lowest |
| 5.00 | Analysis of Data and test results and documentation | 1 | LS | 30,00,000 ₹35,40,000 Lowest |
| 6.00 | Preparation of Draft DPR & Discussions on draft DPR with Technical Committee members and submission of 5 hard copies & Soft copy in 2 Nos. Pendrive. | 1 | LS | 1,20,00,000 ₹1,41,60,000 Lowest |
| 7.00 | Preparation of Final DPR for RLA study, Renovation and Modernization/ Uprating (R&M/RMU) study of 4 nos. Units of Kadamparai Pumped Storage Power House and submission of 20 hard copies & Soft copy in 2 Nos. Pendrive. | 1 | LS | 60,00,000 ₹70,80,000 Lowest |
| 8.00 | Preparation of Tender specification for RMU and submission of 20 hard copies & Soft copy in 2 Nos. Pendrive. | 1 | LS | 1,00,00,000 ₹1,18,00,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
11 Aug 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE/Hydro
Chief Engineer/Hydro, 144AnnaSalai, Chennai-02
Residual Life Assessment Study of 4X100MW Kadamparai Pumped storage PH
2025_EB_565635_1
HE2500
Open Tender
Miscellaneous Services
Item Rate
240 days
Kadamparai
refer tender
3 documents required · 3 mandatory
₹0
₹3 L
Yes
30 Oct 2025
6 Jun 2025
12 Aug 2025
6 Jun 2025
11 Aug 2025
9 Jun 2025
Amount
COLD SURVEY (with water depleted condition)Inspection of water conducting system (around 3.5 Kms in length, & 3m dia)viz., Head Race Tunnel (HRT), Head Race Surge Shaft (HRSS) height of 86.5m & 15m dia , Tail Race Tunnel (TRT) & Tail Race Surge shaft (TRSS) of height 65.5m & dia of 20m, along with other civil works, all hydro-mechanical and electro-mechanical equipments including Governor system & Control systems using specialised trolley arrangement to travel into the water conducting system for inspection.
HOT SURVEY (machine in running condition): Survey and observations of equipments to ascertain their conditions and identification of problem area for analysis and conducting tests as per CEA guidelines by experts in each and every area to be tested has to be engaged. Tests: 1. Diagnostic tests on Generating Units. 2 Diagnostic studies on Mechanical Equipment viz. runner, guide vanes, shafts, etc. 3. Dynamic Behaviour Tests/ Vibration Analysis 4.Structural Studies 5. Non- Destructive and Destructive type tests
Model testing along with Computational Fluid Dynamic (CFD) Analysis to be performed in order to observe the Output of the turbine & study for the enhancement of the machine efficiency by considering turbine runner profile & further detailed turbine analysis . Hydraulic design of new runner shall be carried out for uprating capability studies for which necessary CFD analysis followed by model study, conducting homologous model. Model test shall be carried out in an internationally accredited laboratory. Prior to testing, approval shall be obtained from TNGECL for the proposed lab.
Various tests have to be conducted on the main equipments in any one of the Units , both in running & idle condition. Dismantling of components to ascertain the conditions of various sub-components , conducting tests with various testing equipments, tools & machineries along with specialised experts in respective testing parameter field has to be engaged. After completion of testing, the dismantled components need to be assembled back in position. (Dismantling, Reassembling and commissioning are under the scope of the Contractor )
Analysis of Data and test results and documentation
Preparation of Draft DPR & Discussions on draft DPR with Technical Committee members and submission of 5 hard copies & Soft copy in 2 Nos. Pendrive.
Preparation of Final DPR for RLA study, Renovation and Modernization/ Uprating (R&M/RMU) study of 4 nos. Units of Kadamparai Pumped Storage Power House and submission of 20 hard copies & Soft copy in 2 Nos. Pendrive.
Preparation of Tender specification for RMU and submission of 20 hard copies & Soft copy in 2 Nos. Pendrive.
stage.html
html • 0.03 MB
techsummary_675398.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.14 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Tender_Spec.pdf
Tender Documents • 1.17 MB
BOQ_675398.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .