Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC First lowest |
| 2 | L2₹1.4 Cr+₹8,230.81 (0.06%)Rejected-AOC | ₹1.4 Cr+₹8,230.81 (0.06%) | L2 | Rejected-AOC Second lowest |
Tender Value
₹1.7 Cr
EMD Value
₹50,000
Closing Date
16 Nov 2020, 11:00 amClosed
Regional Engineer
Regional Engineer,Kerala State Nirmithi Kendra ,NS S Karayogam Building, Gandhi Jn , Kottarakkara ,Phone 04742 450399
Construction of class room building and Renovation Work Consists Of R.R Masonry ,Solid Block Masonry ,concrete, electrical Plumbing Works Etc.
2020_KSNK_395431_1
KSNK/TECH/KTR/RUSACR-57/2020
Open Tender
Civil Works - Buildings
Item Rate
240 days
Nilamel
Refer NIT
7 documents required · 7 mandatory
₹5,000
online
₹50,000
Yes
29 Dec 2020
28 Oct 2020
18 Nov 2020
28 Oct 2020
16 Nov 2020
28 Oct 2020
28 Oct 2020 - 16 Nov 2020
Amount
Ground floor 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6
14.29 Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.
10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mildsteel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall withdash fastener, including fixing of necessary butt hinges and screws and applying apriming coat of approved steel primer, all complete as per the direction ofEngineer In charge.
10.11.2 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
10.27.5 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x 160 mm
10.30.1 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
13.1.2 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.7.1 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.4.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.40 Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:
13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
13.50.1 Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)
13.84.2 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
10.17 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
First floor Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 5.2.2
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
14.29 Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows
10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mildsteel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall withdash fastener, including fixing of necessary butt hinges and screws and applying apriming coat of approved steel primer, all complete as per the direction ofEngineer In charge.
10.11.2 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
10.27.5 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x 160 mm
10.30.1 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
13.1.2 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.7.1 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.4.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.40 Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:
13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
13.50.1 Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)
13.84.2 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
10.17 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Electrical works GF & FF Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required. Group C1.10.3 light points
ceiling fan points
6 amps plug point
Wiring for circuit/submain wiring along with earth wire with following sizes of FR PVC insullated copper conductor single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (16amp power plug point)1.14.2
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 amps switch(1.24.1)
3 pin 5/6 amps socket outlet(1.24.4)
15/16 amp switch(1.24.3)
6 pin 15/16 amp socket outlet(1.24.5)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23 3 module
4 module
6 module
8 module
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface / recess complete with loose wire box,terminal connections for all incoming & outgoing circuits duly pre wired with suitable size FRLS PVC insulated copper conductor upto terminal blocks,tinned copper bus bar ,neutral link ,earth bar din bar ,detachable gland plate ,inter connections,powder painted including earthing etc.as required ( but without MCB/ RCCB/isolator ) . 2+12 way/14 way ,double door 2.7.6
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Suppling and fixing following rating , double pole ,240 volts isolator in the existing MCB DB complete with connections ,testing & commissioning etc.as required . 40amps
Suppling and fixing following rating , double pole ( single phase & neutral )240 volts ,Residual Current Circuit Breaker (RCCB/ELCB) having a sensitivity current upto 300 milli amps in the existing MCB DB complete with connections ,testing & commissioning etc.as required . 63 amps2.14.3
Supplying & fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc.as required.1.25
Supplying and fixing 1200mm ceiling fan using 16/0.20mm 3 core round copper wire connect with existing ceiling rose fittings, connecting, commissioning including all materials, and labour charges etc. complete OD
Supplying and fixing 20W LED tube set fitting on TW round block suspension in suitable positio, using 16/0.20 mm 3 core round copper wire connect with existing three plate ceiling rose fixing, connecting, commissioning including all labour charges etc. complete OD
Renovation Work-ADMINISTRATION BLOCK ROOFING 50.10.1 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
GI sheet OD
ADMINISTRATION BLOCK FLOORING-15.1 Demolishing lime concrete manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer - in- Charges.
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm
4 TOILET BLOCK BOYS 9.123 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogeneous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.
9.124.2 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mm x 1 mm, painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (Push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rails of sixe 100mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100 mm x 8 mm complete as per manufacturer's specifications and direction of Engineer -in-charge.Decorative finish (both side wood grained finish) 3
14.53.1 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
GI SHEET
Plumbing maintenance for toilet block
Mathematics Department Flooring and celing11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
50.12.4.2 Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
21.5 Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
21.6 Providing and fixing 6 mm dia. G I level adjusting hangers ( upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-Charge.
Economics dept. Flooring and Celing 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
50.12.4.2 Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
21.5 Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
21.6 Providing and fixing 6 mm dia. G I level adjusting hangers ( upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-Charge.
Commerce Dept Flooring11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Renovation of Science lab(Chemistry) 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.12.1 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Anodized (AC 15) aluminium tubular handle bar
21.13 Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge
A C P sheet OD
Renovation of science lab(Botany lab) 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
21.12.1 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Anodized (AC 15) aluminium tubular handle bar
21.13 Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
50.6.1.2 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complet
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal si
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.42 Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer'sspecification.
13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm
26.22.1 Providing and fixing false ceiling at all heights with integral densified calciumsilicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reductioncoefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85%(minimum). Non combustible as per BS:476 (part-4), fire performance as perBS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043W/m K as per ASTM 518:1991,in true horizontal level suspended on interlockingmetal T-Grid of hot dipped galvanised iron section of 0.33mm thick(galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm oflength 1200 mm and secondary intermediate cross-T of size 24x32 mm oflength 600mm to form grid module of size 600 x 600 mm, suspended fromceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fullythreaded hanger rod upto 1000 mm length and L-shape level adjuster of size85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mmof length 3000 mm to be fixed on periphery wall / partition with the help ofplastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.Sscrews. The work shall be carried out as per specifications, drawing and asper directions of the Engineer-in-Charge.With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles
ACP sheet 55 .00sqm
Renovation of science LAB 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
21.12.1 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Anodized (AC 15) aluminium tubular handle bar
21.13 Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
ACP sheet 85 .00sqm
CANTEEN RENOVATION 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.40 Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:
13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
Shelves
ELECTRICAL WORKS- Chemistry lab-Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required. Group C1.10.3 light points
ceiling fan points
6 amps plug point
Wiring for circuit/submain wiring along with earth wire with following sizes of FR PVC insullated copper conductor single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (16amp power plug point)1.14.2
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.24- 5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1.27.1
Supplying & fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc.as required.5.2
Non scheduled itemsSupplying and fixing 1200mm ceiling fan using 16/0.20mm 3 core round copper wire connect with existing ceiling rose fittings, connecting, commissioning including all materials, and labour charges etc. complete OD
Supplying and fixing 14W LED connect with angle batten fixing, connecting, commissioning including all labour charges etc. complete OD
Supplying and fixing 20W LED tube set fitting on TW round block suspension in suitable positio, using 16/0.20 mm 3 core round copper wire connect with existing three plate ceiling rose fixing, connecting, commissioning including all labour charges etc. complete OD
PLUMBING & SANITARY INSTALLATION-Prioviding and fixing laboratory sink with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern ,including painting of fittings, and brackets, cuttings, and making good the walls wherever required: white vitreous china flat back wash basin size 450 x 300mm with a single 15mm C.P brass pillar tap including cost of all materials & labour charges etc.complete OD.Lab 2
Providing & fixing CP angle valve for basin mixer gyser points of approved quality conforming to IS 8931, 15mm nominal bore.17.10.1
Suppling and laying 25 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete OD
Suppling and laying 32 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete
Suppling and fixing water point [ swan neck laboratary tap ( sink tap) quarter thread ] with all connection and fittings including cost of all materials, labour charges etc. complete OD
Providing 6" silt with CP gratings including cost of all materials and labour charges etc.complete.OD
BOTANY LAB- PLUMBING & SANITARY INSTALLATION Prioviding and fixing laboratory sink with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern ,including painting of fittings, and brackets, cuttings, and making good the walls wherever required: white vitreous china flat back wash basin size 450 x 300mm with a single 15mm C.P brass pillar tap including cost of all materials & labour charges etc.complete OD
Providing & fixing CP angle valve for basin mixer gyser points of approved quality conforming to IS 8931, 15mm nominal bore.17.10.1
Suppling and laying 25 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete OD
Suppling and laying 32 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete
Suppling and fixing water point [ swan neck laboratary tap ( sink tap) quarter thread ] with all connection and fittings including cost of all materials, labour charges etc. complete OD
Providing 6" silt with CP gratings including cost of all materials and labour charges etc.complete.OD
Physics lab-Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required. Group C1.10.3light points
ceiling fan points
6 amps plug point
Wiring for circuit/submain wiring along with earth wire with following sizes of FR PVC insullated copper conductor single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (16amp power plug point)1.14.2
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.24 5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23 3 module
4 module
6 module
8 module
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface / recess complete with loose wire box,terminal connections for all incoming & outgoing circuits duly pre wired with suitable size FRLS PVC insulated copper conductor upto terminal blocks,tinned copper bus bar ,neutral link ,earth bar din bar ,detachable gland plate ,inter connections,powder painted including earthing etc.as required ( but without MCB/ RCCB/isolator ) . 2+12 way/14 way ,double door 2.7.6
Suppling and fixing following rating , double pole ,240 volts isolator in the existing MCB DB complete with connections ,testing & commissioning etc.as required . 40amps 2.14.3
Suppling and fixing following rating , double pole ( single phase & neutral )240 volts ,Residual Current Circuit Breaker (RCCB/ELCB) having a sensitivity current upto 300 milli amps in the existing MCB DB complete with connections ,testing & commissioning etc.as required . 63 amps2.14
Supplying & fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc.as required.5.2
Non scheduled items-Supplying and fixing 1200mm ceiling fan using 16/0.20mm 3 core round copper wire connect with existing ceiling rose fittings, connecting, commissioning including all materials, and labour charges etc. complete OD
Supplying and fixing 14W LED connect with angle batten fixing, connecting, commissioning including all labour charges etc. complete OD
Supplying and fixing 20W LED tube set fitting on TW round block suspension in suitable positio, using 16/0.20 mm 3 core round copper wire connect with existing three plate ceiling rose fixing, connecting, commissioning including all labour charges etc. complete OD
PLUMBING & SANITARY INSTALLATION Prioviding and fixing laboratory sink with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern ,including painting of fittings, and brackets, cuttings, and making good the walls wherever required: white vitreous china flat back wash basin size 450 x 300mm with a single 15mm C.P brass pillar tap including cost of all materials & labour charges etc.complete OD Lab
Providing & fixing CP angle valve for basin mixer gyser points of approved quality conforming to IS 8931, 15mm nominal bore.17.10.1
Suppling and laying 25 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete OD
Suppling and laying 32 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete
Suppling and fixing water point [ swan neck laboratary tap ( sink tap) quarter thread ] with all connection and fittings including cost of all materials, labour charges etc. complete OD
Providing 6" silt with CP gratings including cost of all materials and labour charges etc.complete.OD
Computer lab-Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required. Group C1.10.3 light points
ceiling fan points
6 amps plug point
Wiring for circuit/submain wiring along with earth wire with following sizes of FR PVC insullated copper conductor single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (16amp power plug point)1.14.2
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.24 5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23 3 module
4 module
6 module
8 module
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface / recess complete with loose wire box,terminal connections for all incoming & outgoing circuits duly pre wired with suitable size FRLS PVC insulated copper conductor upto terminal blocks,tinned copper bus bar ,neutral link ,earth bar din bar ,detachable gland plate ,inter connections,powder painted including earthing etc.as required ( but without MCB/ RCCB/isolator ) . 2+12 way/14 way ,double door 2.7.6
Suppling and fixing following rating , double pole ,240 volts isolator in the existing MCB DB complete with connections ,testing & commissioning etc.as required . 40amps 2.14.3
Suppling and fixing following rating , double pole ( single phase & neutral )240 volts ,Residual Current Circuit Breaker (RCCB/ELCB) having a sensitivity current upto 300 milli amps in the existing MCB DB complete with connections ,testing & commissioning etc.as required . 63 amps2.14
Supplying & fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc.as required.5.2
Non scheduled items-Supplying and fixing 1200mm ceiling fan using 16/0.20mm 3 core round copper wire connect with existing ceiling rose fittings, connecting, commissioning including all materials, and labour charges etc. complete OD
Supplying and fixing 14W LED connect with angle batten fixing, connecting, commissioning including all labour charges etc. complete OD
Supplying and fixing 20W LED tube set fitting on TW round block suspension in suitable positio, using 16/0.20 mm 3 core round copper wire connect with existing three plate ceiling rose fixing, connecting, commissioning including all labour charges etc. complete OD
Canteen-Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required. Group C1.10.3 light points
ceiling fan points
6 amps plug point
Wiring for circuit/submain wiring along with earth wire with following sizes of FR PVC insullated copper conductor single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (16amp power plug point)1.14.2
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.24 5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23 3 module
4 module
6 module
8 module
Supplying & fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc.as required.5.2
Non scheduled items-Supplying and fixing 1200mm ceiling fan using 16/0.20mm 3 core round copper wire connect with existing ceiling rose fittings, connecting, commissioning including all materials, and labour charges etc. complete OD
Supplying and fixing 14W LED connect with angle batten fixing, connecting, commissioning including all labour charges etc. complete OD
Supplying and fixing 20W LED tube set fitting on TW round block suspension in suitable positio, using 16/0.20 mm 3 core round copper wire connect with existing three plate ceiling rose fixing, connecting, commissioning including all labour charges etc. complete OD
PLUMBING & SANITARY INSTALLATIONPrioviding and fixing Kithen sink with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern ,including painting of fittings, and brackets, cuttings, and making good the walls wherever required: white vitreous china flat back wash basin size 1100 x 600mm with a single 25mm C.P brass pillar tap including cost of all materials & labour charges etc.complete OD
Providing & fixing CP angle valve for basin mixer gyser points of approved quality conforming to IS 8931, 15mm nominal bore.17.10.1
Suppling and laying 25 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete OD
Suppling and laying 32 mm PVC pipe with fittings such as tees, bents, elbows, check nuts etc. including excovation or cutting and making walls good and floors including cost of all materials, labour charges etc. complete
Suppling and fixing water point [ swan neck laboratary tap ( sink tap) quarter thread ] with all connection and fittings including cost of all materials, labour charges etc. complete OD
Providing 6" silt with CP gratings including cost of all materials and labour charges etc.complete.OD
CLASSROOMS-Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required. Group C1.10.3 light points
ceiling fan points
6 amps plug point
Wiring for circuit/submain wiring along with earth wire with following sizes of FR PVC insullated copper conductor single core cable in surface / recessed medium class PVC conduit as required 2x2.5 sq.mm + 1x2.5 sq.mm earth wire (16amp power plug point)1.14.2
Suppling and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.24 5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1.23 3 module
4 module
6 module
8 module
Supplying & fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc.as required.5.2
Non scheduled items-Supplying and fixing 1200mm ceiling fan using 16/0.20mm 3 core round copper wire connect with existing ceiling rose fittings, connecting, commissioning including all materials, and labour charges etc. complete OD
Supplying and fixing 14W LED connect with angle batten fixing, connecting, commissioning including all labour charges etc. complete OD
Supplying and fixing 20W LED tube set fitting on TW round block suspension in suitable positio, using 16/0.20 mm 3 core round copper wire connect with existing three plate ceiling rose fixing, connecting, commissioning including all labour charges etc. complete OD
Instalation of alternate energy sources-Instalation of alternate energy sources of 7500va solar power system(suntek) 12 volt battery 200Ah,330w photovoltaic module 15 nos of panel,panel structure one set and MPPt charge controller 72 volts(suntek)one nos including all fittings and labour charge with five years warranty and maintenance etc complete(5000 volt solar panel-20Kwh current one day)
ks.chandralal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .